Results 171 to 180 of about 37,901 (272)

Investigation of the Critical Overhang Angle in Fused Filament Fabrication Technology

open access: yesMacromolecular Symposia, EarlyView.
ABSTRACT In fused filament fabrication, overhangs are challenging because each deposited layer requires partial support from the previous layer. The frequently cited 45° guideline for unsupported printing originates from empirical practice and does not consistently represent process‐specific behavior.
Nicolae Razvan Mititelu   +4 more
wiley   +1 more source

Automating Subthalamic Deep Brain Stimulation Programming with Evoked Resonant Neural Activity in Parkinson's Disease

open access: yesMovement Disorders, EarlyView.
Abstract Background Optimal outcomes from subthalamic nucleus deep brain stimulation (STN‐DBS) for Parkinson's disease (PD) depend on accurate stimulation of an ideal functional target within the dorsolateral STN. Clinical programming is heuristic, and objective methods are needed to improve efficiency and consistency.
Kanae J. Nagao   +9 more
wiley   +1 more source

Surgery and positive Bakry-Émery Ricci curvature. [PDF]

open access: yesCalc Var Partial Differ Equ
Reiser P, Tripaldi F.
europepmc   +1 more source

Offline Reconstruction of Diffusion MRI Acquisitions for Comparison Between Complex PCA‐Based and AI‐Based Denoising

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose Optimal diffusion MRI (dMRI) data for image denoising is often unavailable from scanner reconstruction. In this work, we make available an offline reconstruction pipeline for GE dMRI acquisitions, giving access to complex dMRI data. Furthermore, we compare the efficacy of GE HealthCare's AIR‐Recon DL (ARDL), a proprietary convolutional
Francesco D'Antonio   +4 more
wiley   +1 more source

Autonomy for MRI Field Cameras: Synchronization, Self‐Calibration, and Sequence Detection

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose This work aims to provide a workflow for operating NMR field probes in MR scanners independently of pulse programming, scanner TTL trigger pulses and dedicated calibration sequences. Methods An independent timing system and limited prior knowledge about relative probe positions enable synchronous field measurement, probe position ...
Oskar Björkqvist, Klaas P. Pruessmann
wiley   +1 more source

A Hybrid RF Coil for Whole‐Brain Imaging in Non‐Human Primates at 7 T

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose Ultra‐high field MRI (≥ 7 T) offers unprecedented potential for mapping non‐human primate (NHP) brain function. However, complex electromagnetic systems are required to meet the challenges of UHF imaging and the mechanical demands of awake NHP studies.
Elias Djaballah   +5 more
wiley   +1 more source