Results 211 to 220 of about 41,764 (308)

Motion‐ and Field‐Robust Mesoscopic Whole‐Brain T2*$$ {T}_2^{\ast } $$‐Weighted Imaging at 7 and 11.7 T Using Servo Navigation

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To mitigate artifacts related to motion and field changes in high‐resolution T2*$$ {T}_2^{\ast } $$‐weighted human brain imaging using servo navigation at ultra‐high fields up to 11.7 T. Methods MR‐based servo navigators were integrated into a segmented 3D‐EPI sequence to allow for prospective correction of involuntary head motion and ...
Matthias Serger   +15 more
wiley   +1 more source

Quantitative Comparison of Multi‐Echo Spin Echo and Multi‐Echo Gradient Echo Myelin Water Imaging in a Panel of Mbp Enhancer‐Edited Mouse Lines

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To evaluate the correspondence between myelin water fraction (MWF) estimates derived from multi‐echo spin echo (MESE) and multi‐echo gradient echo (MGRE) imaging in fixed mouse brain tissue, using a panel of myelin basic protein (Mbp) enhancer‐edited mouse lines exhibiting graded hypomyelination.
Vladimir Grouza   +11 more
wiley   +1 more source

Respiratory Motion‐Corrected Model‐Based 3D Water‐Fat MRA of the Thorax at 0.55 T

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose The goal of this study was to develop a 5‐min 3D MRA acquisition at 0.55 T with predictable scan time, 100% data efficiency, and robust water‐fat separation. Methods For full data efficiency, the proposed method combined self‐gating with retrospective motion correction while ensuring a predictable 5‐min scan time.
Robert Stoll   +5 more
wiley   +1 more source

Automated Coregistered Segmentation for Volumetric Analysis of Multiparametric Renal MRI

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose This study aims to develop and evaluate a fully automated deep learning‐driven postprocessing pipeline for multiparametric renal MRI, enabling accurate kidney alignment, segmentation, and quantitative feature extraction within a single efficient workflow. Methods Our method has three main stages.
Aya Ghoul   +8 more
wiley   +1 more source

A slightly oblate dark matter halo revealed by a retrograde precessing Galactic disk warp [PDF]

open access: green
Yang Huang   +9 more
openalex   +1 more source

Structural Basis of the Light‐Switchable Interaction between an Azobenzene Side Chain in a Biosynthetic Protein and α‐Cyclodextrin

open access: yesChemistryOpen, EarlyView.
X‐ray crystallographic analysis of super‐folder green fluorescent protein (sfGFP), a common reporter protein, displaying p‐(phenylazo)‐L‐phenylalanine (Pap) at amino acid position 39 on its surface in complex with α‐cyclodextrin (α‐CD) reveals an unexpected conformation of the photoswitchable side chain and illustrates its light‐dependent ...
Andreas Eichinger   +4 more
wiley   +1 more source

Home - About - Disclaimer - Privacy