Results 141 to 150 of about 5,423,244 (192)
Some of the next articles are maybe not open access.
Accuracy of Whole-Body Plethysmography Requires Biological Calibration
Chest, 2009Specific airway resistance (sRaw) measured by whole-body plethysmography in young children is increasingly used in research and clinical practice. The method is precise and feasible. However, there is no available method for calibration of the resistance measure, which raises concern of accuracy.
Hans Bisgaard, Birgitte Hanel
exaly +4 more sources
Emotions and Airway Resistance in Asthma: Study With Whole Body Plethysmography
Psychophysiology, 2005AbstractThe role of emotions as potential triggers of asthmatic airway obstructions was examined by whole body plethysmography. Three affectively homogeneous picture series (IAPS) were presented with video glasses to induce pleasant, unpleasant, and neutral emotional states in 32 asthmatic and 32 nonasthmatic participants while they were seated in a ...
Andreas von Leupoldt, Bernhard Dahme
exaly +3 more sources
Use of Whole-Body Plethysmography to Compare Bronchodilator Inhaler Efficacy
Respiration, 1998Whole-body plethysmography is not included in guidelines from regulatory authorities for the development of treatments or delivery devices for lung disease, despite its potential advantages compared to spirometry. Two separate studies were undertaken to assess the use of specific airway conductance (sG<sub>aw</sub>) as a pharmacodynamic ...
A H Morice, A H Morice
exaly +3 more sources
Automating the Correction of Flow Integration Drift During Whole-Body Plethysmography [PDF]
Prolonged measurement of total body volume variations (deltaVb) with whole-body, flow-based plethysmography (WBP) results in a drift of the signal due to changes in temperature and humidity inside the plethysmograph and to numerical integration of the ...
Andrea Aliverti +2 more
exaly +2 more sources
Barometric whole body plethysmography in mice
Journal of Applied Physiology, 2005There has been significant utilization of the technique described by Hamelmann et al. ( Am J Respir Crit Care Med 156: 766–775, 1997) in which a parameter, enhanced pause (Penh), related to airways responsiveness is noninvasively measured by unrestrained plethysmography (UP). Investigating this technique, we sought to answer these questions: 1) How do
J. Schwarze, E. Hamelmann, E. W. Gelfand
openaire +1 more source
Infant Whole-Body Plethysmography
2005Measurement of lung volume is an important part of infant lung function testing both for assessing growth and development of the lungs in health and disease, and for interpretation of volume ...
Monika Gappa, Georg H�lskamp
openaire +1 more source
An improvement in whole body plethysmography.
The American review of respiratory disease, 1975A simple method for greatly reducing thermal drift and acoustic noise in constant-volume, whole body plethysmography is described. Evaluation and adjustment for any particular clinical application can be carried out in a few moments. The device itself consists of a 20- to 25-gauge needle, a "Y" tube, and a 1-liter or more vessel, and may be assembled ...
G H, Bryant, J E, Hansen
openaire +1 more source
Whole-Body Plethysmography in the Clinical Assessment of Infants with Bronchopulmonary Diseases
Respiration, 2009Infant whole-body plethysmography offers a unique possibility of measuring end-expiratory resting level (thoracic gas volume; TGV), and hence lung volume in its close interrelationship to airway function (airway resistance; R<sub>aw</sub>, its reciprocal value, airway conductance, G<sub>aw</sub>).
openaire +2 more sources
Medizinische Klinik (Munich, Germany : 1983), 2011
Whole-body plethysmography is considered the "gold standard" for intrathoracic gas volume measurements and the measurement of specific airway resistance. These parameters are essential to assess a restrictive impairment, overinflation of the lungs and airflow obstruction.
openaire +1 more source
Whole-body plethysmography is considered the "gold standard" for intrathoracic gas volume measurements and the measurement of specific airway resistance. These parameters are essential to assess a restrictive impairment, overinflation of the lungs and airflow obstruction.
openaire +1 more source
[Evaluation of airway resistance determined by whole-body plethysmography].
Biulleten' eksperimental'noi biologii i meditsiny, 1989Methods of estimation of the airway resistance by flow-pressure curve obtained in whole-body plethysmography are investigated. The analysis of the physical processes controlling the flow-limitation during expiration shows that these methods are useful only for healthy subjects for the estimation of the airway resistance.
V K, Kuznetsova, G A, Liubimov
openaire +1 more source

