Results 151 to 160 of about 255,138 (334)

Data‐Driven Dual‐Channel Dynamic Event‐Triggered Load Frequency Control for Multiarea Power Systems Under DoS Attacks

open access: yesEnergy Science &Engineering, EarlyView.
ABSTRACT System dynamics uncertainties and cyberattacks pose significant challenges to load frequency control in power systems. This paper presents a data‐driven load frequency control strategy for interconnected multi‐area power systems subject to denial‐of‐service attacks that disrupt both feedforward and feedback communication channels.
Yuhao Chen   +4 more
wiley   +1 more source

Design and operating experience on the US Department of Energy experimental Mod-0 100-kW wind turbine [PDF]

open access: yes
The experimental wind turbine was designed and fabricated to assess technology requirements and engineering problems of large wind turbines. The machine has demonstrated successful operation in all of its design modes and served as a prototype ...
Birchenough, A. G., Glasgow, J. C.
core   +1 more source

Development of a Novel Modified Mean‐Line Approach for Performance Prediction of Axial Compressors

open access: yesEnergy Science &Engineering, EarlyView.
ABSTRACT There is significant importance in accurate prediction of axial flow compressor characteristics at different conditions. Different techniques and models have been proposed for performance prediction of axial compressors. Because of its lower computational cost and high speed the meanline algorithm has been widely applied in preliminary design ...
Sina Hassanlue   +2 more
wiley   +1 more source

Design and laboratory test of black‐start control mode for wind turbines

open access: hybrid, 2019
Martin Shan   +3 more
openalex   +1 more source

The Role of Digital Twin Technology in Enhancing Energy Efficiency in Buildings: A Systematic Literature Review

open access: yesEnergy Science &Engineering, EarlyView.
Digital Twin (DT) technology enhances building energy efficiency by enabling continuous monitoring, predictive maintenance, and operational optimization within Building Energy Management Systems. Through real‐time data integration and simulation, DTs provide dynamic feedback loops that optimize performance, reduce operational costs, and improve ...
Suqi Wang   +6 more
wiley   +1 more source

Optimized Asymmetrical Fuzzy‐2DOFTIDF Controller for LFC of Three‐Area Multi‐Sources Interconnected Power System Along With HAE‐FC and UPFC Using a New SOA Algorithm

open access: yesEnergy Science &Engineering, EarlyView.
This study proposes a novel Asymmetrical‐Fuzzy Two‐Degree‐of‐Freedom Tilt‐Integral‐Derivative (AF‐2DOF‐TIDF) controller for load frequency control in a multi‐area, multi‐source power system integrating Hydrogen‐Aqua‐Electrolyzer‐Fuel‐Cell (HAE‐FC) units and a Unified Power Flow Controller (UPFC).
Getaneh Mesfin Meseret, M. Bala Anand
wiley   +1 more source

Estimation of the GCV of Coal Using Real‐Time Plant Data

open access: yesEnergy Science &Engineering, EarlyView.
ABSTRACT Online or real‐time strategies of estimating the gross calorific value (GCV) of coal are still not fully explored in academic literature, even though both conventional and sophisticated offline methods for estimating the GCV are well described.
Lethukuthula Nokwazi Vilakazi   +1 more
wiley   +1 more source

Performance Analysis of a Cooling‐Heating‐Electricity‐Ammonia Multigeneration System Integrated Concentrated Photovoltaic Photothermal and Operation Strategy

open access: yesEnergy Science &Engineering, EarlyView.
This article introduces an operation strategy utilizing a hydrogen and biomass collaborative energy storage to regulate the power supply and demand. The results show that the system achieves annual average energy and exergy efficiencies of 87.77% and 67.16%, respectively.
Kai Ding, Ximin Cao, Yanchi Zhang
wiley   +1 more source

Home - About - Disclaimer - Privacy