Results 181 to 190 of about 1,024,785 (258)

Tuning Cation Disorder in LiNi0.5Mn1.5O4 via Room Temperature Continuous‐Flow Co‐Precipitation and Controlled Heat Treatment

open access: yesENERGY &ENVIRONMENTAL MATERIALS, EarlyView.
LiNi0.5Mn1.5O4 (LNMO) precursors were produced at room temperature by Ambient Continuous Turbulent In‐line Mixing (ACTIM) at rates of up to 0.42 kg h−1. The final heat treatment step at 650, 700, or 750 °C, altered cation disorder and the electrochemical behavior of the LNMO cathodes, while the effect of adding MWCNTs to the electrodes, was also ...
Bangxun Yin   +5 more
wiley   +1 more source

A contemporary simple risk score for prediction of severe acute kidney injury after heart transplantation

open access: yesESC Heart Failure, Volume 12, Issue 2, Page 1166-1175, April 2025.
A contemporary simple risk score for prediction of severe AKI after HT. Abstract Background The aim of this study was to develop a simple risk score to estimate severe acute kidney injury (AKI) risk based on a large contemporary heart transplantation (HT) cohort.
Shuangshuang Zhu   +10 more
wiley   +1 more source

Glazing Effects on Dynamic‐Insulation TSC Façades: A CFD‐Supported Experimental Study of Flow, Heat Transfer, and Ventilation Preheating

open access: yesEnergy Science &Engineering, EarlyView.
Glazed transpired solar collectors achieve 48–75% efficiency and 11% more seasonal heat than unglazed designs by cutting convective losses, while both offer complementary benefits for ventilation preheating and dynamic wall insulation, with paybacks of 5.5–6.8 years.
Mohammad Fawaier   +7 more
wiley   +1 more source

Comparative Analysis of Al2O3/Water–TiO2/Chlorophyll Hybrid Nanofluids in a Photovoltaic–Thermal Solar Water Heating System

open access: yesEnergy Science &Engineering, EarlyView.
TiO2/chlorophyll bio‐hybrid nanofluid achieved the highest PVT performance, increasing thermal efficiency to 38.74% and overall efficiency to 51.35%, compared with 35.96% and 48.45% for Al2O3/water and 27.77% and 40.18% for water. The results demonstrate the potential of bio‐hybrid nanofluids for high‐efficiency solar thermal energy conversion ...
Oluwaseyi Omotayo Alabi   +2 more
wiley   +1 more source

Turbulence‐Intensity Effects on the Aerodynamic Performance of an H‐Type Darrieus Wind Turbine: A URANS Parametric Study

open access: yesEnergy Science &Engineering, EarlyView.
Turbulence intensity from 1% to 25% was parametrically tested on a three‐bladed H‐type Darrieus rotor across five tip speed ratios (TSRs) using two‐dimensional URANS. The optimal TSR proved the most efficient and most robust operating point simultaneously, with Cp losses capped at 5.8% even at TI = 25%. ABSTRACT The effect of inlet turbulence intensity
Aydin Ulus
wiley   +1 more source

Home - About - Disclaimer - Privacy