Results 81 to 90 of about 86,943,297 (163)
Energy performance of buildings using electrochromic smart windows with different window-wall ratios
The electrochromic (EC) smart window is a promising intelligent technology for improving the energy performance of a building. When applying a new glazing material, the window-wall ratio (WWR) is regarded as a significant factor related to daylight and ...
Xing, Weiqi (R20503) +5 more
core +1 more source
Energy efficiency in hospitals—where continuous operation with high internal gains and strict comfort needs—demands facade strategies tailored to climate.
Fatma Azize Zülal Aydınol +1 more
doaj +1 more source
THE EFFECT OF THE WINDOW-TO-WALL RATIO ON COOLING ENERGY USAGE AND COMFORT TEMPERATURE
This study presents an investigation of the effect of building envelope, especially glass facade buildings on cooling energy usage and thermal comfort. An office building was modeled with various window-to-wall ratio (WWR) using panasap glass with SC=0 ...
Budhiyanto, Aris
core
In regions with hot summers and cold winters, elderly care buildings face the dual challenges of high energy consumption and stringent thermal comfort requirements.
Wuying Chen, Bao Xie, Lu Nie
doaj +1 more source
Window-to-Wall Ratio (WWR) influences building energy and daylight performance, yet its implications depend on both façade orientation and geometry. In rapidly urbanizing regions lacking energy regulations, WWR decisions are often made without systematic
Prashant Chhetri
doaj +1 more source
This study examines the daylighting performance of a classroom with bilateral opening typology and an adjacent building on one side. The openings are located on the east and west sides of the classroom, with the adjacent building situated on the west ...
Atthaillah +2 more
doaj +1 more source
High-altitude Andean climates present dual thermal pressure: daytime overheating risk coexists with nighttime heat loss within the same annual cycle. Aggregate energy indicators do not reveal the direction of thermal discomfort, limiting their utility ...
Ramiro Correa-Jaramillo +1 more
doaj +1 more source
In this study, thermal comfort parameters and illuminance (E) are investigated in four differently oriented workspaces at Najran University, using an R data logger and an Extech HD450 lux meter in accordance with international standards.
Shukri Mohammed Elbellahy
doaj +1 more source
A systematic literature review: building window's influence on indoor circadian health. [PDF]
Ghaeili Ardabili N, Wang J, Wang N.
europepmc +1 more source
Quantifying input parameters influence in UBEM simulation results: the window-to-wall ratio case [PDF]
In the field of urban building energy models (UBEM), the significant mismatch between simulation results and energy metered data is one of the most important barriers when using them as a planning tool.
Pagès Ramon, Anna +2 more
core +1 more source

