Results 131 to 140 of about 246,052 (262)
This work presents a magnetic bronchoscopy robot with a novel multi‐segment variable stiffness catheter. This catheter can not only move flexibly in the narrow bronchi but also harden according to the need to provide support. Combined with remote wireless magnetic field drive, it provides a more precise and effective solution for biopsy of deep lung ...
Shucong Yin +10 more
wiley +1 more source
Patent for improvements in design for wire rope fasteners, includes ...
Widmer, Louis John
core
Abstract Medial meniscus posterior root tears and anterior cruciate ligament (ACL) injuries disrupt knee biomechanics and accelerate joint degeneration, particularly in the presence of varus malalignment. This technical note describes a combined surgical approach that integrates medial meniscus posterior root repair, ACL reconstruction, and high tibial
Fardis Vosoughi +5 more
wiley +1 more source
Study on Abnormal Winding Behaviors of Hoisting Steel Wire Rope in Ultra-Deep Vertical Shaft
During multi-layer winding of hoisting steel wire ropes for ultra-deep vertical shafts on double broken-line drums, abnormal winding behaviors such as rope interlocking, rope jumping and disordered rope arrangement may occur, accelerating abrasion and ...
Wenbo Fan +4 more
doaj +1 more source
Abstract We describe a surgical technique repairing medium‐to‐large anterosuperior rotator cuff (RC) tear that combines long head of the biceps tendon (LHBT) augmentation with a dermal allograft patch using a knotless double‐row repair. LHBT augmentation is done using a triple‐loaded anchor placed 5 mm posterior to the bicipital groove at the bone ...
Gabriel Antonio A. Escueta +5 more
wiley +1 more source
Arthroscopic Bone Block Procedure Using Iliac Crest Autograft and Labral Advancement and Repair
Abstract Recurrent anterior shoulder instability with significant glenoid bone loss requires bony augmentation to restore stability and prevent recurrence. Arthroscopic iliac crest bone block reconstruction offers an anatomical solution while avoiding morbidity of coracoid transfer.
K. N. Subramanian +3 more
wiley +1 more source
Determination of the Bending Properties of Wire Rope Used in Cable Barrier Systems. [PDF]
Bruski D.
europepmc +1 more source
Failure Analysis on the Wire Rope for Lifting Equipment [PDF]
The failure analysis o the wire rope for the lifting equipment is the project based on the real life case study. The lifting equipment is the pedestal crane that widely used at the offshore facilities. This report contains the detail explanation on the
Suhaimi Bin Shazali, Suhaimi
core
Abstract Anterior cruciate ligament rupture, a common sports‐related knee injury, often causes instability and functional impairment and increases the long‐term risk of osteoarthritis. Traditional remnant‐preserving anatomical reconstruction is the first‐line treatment for midsubstance tears, but optimal management of femoral‐side avulsion injuries ...
Haiwei Yan, Xiaoling Qin
wiley +1 more source
En ocasiones, se desconocen las características originales de un cable de acero. En estos casos, generalmente se estima ellímite de rotura de un cable a partir del límite de rotura de un alambre del cable.
F. Aguilar Parés +1 more
doaj