Results 211 to 220 of about 246,052 (262)
Some of the next articles are maybe not open access.

Failure Analysis of a Wire Rope

Practical Failure Analysis, 2002
Abstract Wire ropes, pulleys, counterweights, and connecting systems are used for auto tensioning of contact wires of electric railways. A wire rope in one such auto tensioning system suffered premature failure. Failure investigation revealed fatigue cracks initiating at nonmetallic inclusions near the surface of individual wire strands ...
openaire   +1 more source

Making Wire Rope and the Wire Rope Industry (1840–48)

2020
Abstract After missing out on the Schuylkill Bridge contract, John turned his attention to manufacturing wire rope, an entirely new idea in the United States. John undertook an extensive campaign to have his ropes adopted on the Allegheny Portage Railroad.
openaire   +1 more source

WIRE ROPE LUBRICATION

Scientific Lubrication, 1951
Part One in this series appeared in our June issue and dealt with early and more recent investigations which have proved the importance of wire rope lubrication. Part Two (July issue) covered the duties and properties of wire rope lubricants.
openaire   +2 more sources

Wire Rope Transmission Losses

Proceedings of the Institution of Mechanical Engineers, 1963
Transmission losses are determined for 20 wire ropes commonly used in crane and hoist practice. The apparatus and procedure used in determining the losses are described and the results are presented in the form of graphs. From these graphs the law governing the losses is established.
openaire   +1 more source

Friction in Wire Rope

1990
Chapter 3 considered the static response of a simple straight strand with the cross section shown in Figure 3.1. It was assumed in that chapter that the wires were frictionless. It will now be shown that friction plays a very small role in the axial loading of a simple strand.
openaire   +1 more source

Wire Rope

Scientific American
Peter R.N. Childs, Marc A. Masen
  +4 more sources

Wire Rope Slings

Offshore Technology Conference, 1977
ABSTRACT The magnitude of structures being lifted offshore with wire rope slings is rapidly becoming heavier and heavier. Lifts of 75 to 250 tons are not uncommon. Faced with such load magnitudes, the rigger is many times faced with a delicate problem. He has a multiple choice.
openaire   +1 more source

A new MFL imaging and quantitative nondestructive evaluation method in wire rope defect detection

Mechanical Systems and Signal Processing, 2022
Yanhua Sun, Shiwei Liu, Yihua Kang
exaly  

WIRE ROPE DRESSING

Anti-Corrosion Manual, 1972
The Port of London Authority has solved a £1,000 wire rope corrosion problem at Tilbury Docks by the use of an anti-corrosion dressing.
openaire   +1 more source