Results 61 to 70 of about 246,052 (262)

Nonlinear isolation performance of 6 × 19 wire rope of different lengths under compression

open access: yesAdvances in Mechanical Engineering, 2021
Stainless steel wire rope isolator is widely used in engineering. To optimize design of the isolator, loading, and unloading characteristics of the 6 × 19 6 mm wire rope under compression are investigated. Ropes of different lengths are tested to get the
Genlin Mo   +3 more
doaj   +1 more source

Warmed intravenous fluid administration attenuated a reduction in body temperature in anaesthetised horses

open access: yesEquine Veterinary Journal, EarlyView.
Abstract Background Peri‐anaesthetic hypothermia is a well‐documented complication of general anaesthesia and is associated with prolonged recovery, impaired wound healing, and delayed coagulation. Fluid warmers can be used to mitigate heat loss, but there is little evidence supporting their effectiveness in equine anaesthesia.
Miranda P. Starr   +4 more
wiley   +1 more source

High resolution magnetic induction wire rope test, part 2: detection of broken wires in wire ropes by analysis of the scatterfield

open access: yes, 2022
Compendium of papers.Held at: Colorado School of Mines, Arthur Lakes Library.Congress paper discusses high resolution wire rope testing compared with electromagnetic wire rope inspection.
Nussbaum, Joerg-Michael
core  

Posterolateral corner reconstruction using hamstrings grafts—A comparative biomechanical study of three techniques

open access: yesKnee Surgery, Sports Traumatology, Arthroscopy, EarlyView.
Abstract Purpose To compare three posterolateral corner (PLC) reconstruction techniques—the popliteofibular loop (PFLoop), the modified LaPrade (LP) and modified Arciero (AR) techniques—in restoring knee laxity in varus (VR), external tibial rotation (ER) and posterior tibial translation (PTT). Methods Nine cadaveric knees were subjected to 8Nm VR, 5Nm
Marcos Barbieri Mestriner   +5 more
wiley   +1 more source

Designing ZV and ZVD Input Shapers Using the Designed Fixed Output Response Method to Suppress Residual Vibration of Overhead Crane Systems With Trolley Traveling and Payload Hoisting

open access: yesInternational Journal of Mechanical System Dynamics, EarlyView.
ABSTRACT Classical Zero Vibration (ZV) and Zero Vibration and Derivative (ZVD) input shapers are designed around a fixed nominal natural frequency and cannot accommodate the time‐varying dynamics introduced when an overhead crane simultaneously travels and hoists a payload.
Mohammad Alfares, Khaled Alhazza
wiley   +1 more source

Study on the Vibration Characteristics of Wire Rope in Static Testing of Wind Turbine Blades

open access: yesEnergies
Significant vibrations of the traction wire rope can impact the efficiency and accuracy of static testing in wind turbine blade assessments. This study focuses on the vibration characteristics of the wire rope under static loading conditions.
Yingjie Zhang   +5 more
doaj   +1 more source

Expectations regarding rope lubrication today

open access: yes, 2022
OITAF-NACS: ninth symposium, September 16-20, 2004, Vail Marriott Mountain Resort and Spa, Vail, Colorado, USA; International Organization for Transportation by Rope, North American Continental Section.Held at: Arthur Lakes Library, Colorado School of ...
Kopanakis, Georg A.
core  

Leaf heat tolerance in a native Californian shrub responds in expected and unexpected ways to differences in range, season, and sunlight exposure

open access: yesPLANTS, PEOPLE, PLANET, EarlyView.
Earth's ecosystems are experiencing wide‐ranging impacts from global climate change, including increased average and extreme temperatures. These temperature shifts can drastically affect plant physiology, threatening the future of even common plant species. Here, we focus on photosynthetic function in a native Southern California shrub species.
Anna K. M. Bowen   +8 more
wiley   +1 more source

Design and Development of a Modular Ballistic Pendulum for High‐Impulse Measurement in Contact and Near‐Field Explosive Loading

open access: yesPropellants, Explosives, Pyrotechnics, EarlyView.
ABSTRACT Measuring impulse from explosive charges in contact and near‐field configurations presents practical challenges due to wide variation in impulse magnitude. Ballistic pendula are widely used for impulse measurement, but many existing designs are limited to narrow operating envelopes or are poorly suited to repeated contact testing and tamped ...
R. Alford   +3 more
wiley   +1 more source

Evaluation of nondestructive test instruments for wire rope [PDF]

open access: yes
"The critical importance of wire rope integrity to the mining industry has led to the creation of standards for the retirement of wire rope, as well as to the development of electromagnetic devices and procedures that would allow wire ropes to be tested ...

core  

Home - About - Disclaimer - Privacy