Using deep learning generated CBCT contours for online dose assessment of prostate SABR treatments

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Prostate Stereotactic Ablative Body Radiotherapy (SABR) is an ultra‐hypofractionated treatment where small setup errors can lead to higher doses to organs at risk (OARs). Although bowel and bladder preparation protocols reduce inter‐fraction variability, inconsistent patient adherence still results in OAR variability.
Conor Sinclair Smith   +8 more
wiley   +1 more source

Improving dose delivery in non‐coplanar cranial SRS: Stereoscopic x‐ray‐guided mitigation of table walkout errors

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Purpose Linear accelerator (LINAC)‐based single‐isocenter multi‐target (SIMT) treatment has streamlined the cranial stereotactic radiosurgery (SRS) workflow. Though efficient, SIMT delivery adds additional challenges that should be considered, including increased sensitivity to rotational errors for off‐isocenter targets.
Yohan A. Walter   +4 more
wiley   +1 more source

Implementation of needle‐tracking technology for real‐time transrectal ultrasound‐guided interstitial gynecological HDR brachytherapy: A feasibility study

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose To investigate the feasibility of adapting a commercial prostate biopsy system for transrectal ultrasound (TRUS)‐guided hybrid gynecological (GYN) high‐dose‐rate (HDR) brachytherapy (BT). Leveraging 3D‐TRUS and MR image fusion, the prototype system aims to improve real‐time needle placement accuracy.
Lindsey H. Bloom   +8 more
wiley   +1 more source

Accounting for TLD response to CBCT protocols in external beam radiotherapy dose monitoring

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose LiF thermoluminescent dosimeters (TLDs) are commonly used in radiation therapy to verify the delivered dose. Examples include dose verification for complicated treatment setups or cardiovascular implantable electronic devices (CIEDs). TLDs may be present for both the pre‐treatment imaging kilovoltage (kV) beam and the megavoltage (MV ...
Andrew J. White   +5 more
wiley   +1 more source

New proton emitter 188At implies an interaction unprecedented in heavy nuclei. [PDF]

open access: yesNat Commun
Kokkonen H   +23 more
europepmc   +1 more source