Advantages and limitations of navigation‐based multicriteria optimization (MCO) in selectively sparing pharyngeal constrictor muscles in head and neck radiotherapy treatment planning

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Sparing pharyngeal constrictor muscles (PCMs) during radiotherapy improves patient‐reported swallowing function. This study aimed to explore the feasibility of integrating knowledge‐based planning (KBP) with multicriteria optimization (MCO) in Eclipse v18.0 to selectively spare PCM, quantify the required trade‐off in prophylactic ...
Laura K. Howard   +3 more
wiley   +1 more source

Developing reference plans for evaluating global clinical trials credentialing and PSQA systems

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose To develop a practical framework for creating a diverse set of validated reference plans (varying in complexity) and implement a workflow to introduce beam modeling, calibration, and delivery errors into the reference cohort to test and compare various dosimetry audit methodologies.
Fre'Etta M. D. Brooks   +13 more
wiley   +1 more source

Enhanced analysis of gating latency in 0.35T MR‐linac through innovative time synchronization of a motion phantom and plastic scintillation detector

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study aims to evaluate how different gantry angles, breathing rates (BPM), cine image speeds, and tracking algorithms affect beam on/off latency and the subsequent impact on target dose for a 0.35T MR‐Linac with a 6 MV FFF beam.
Mateb Al Khalifa   +4 more
wiley   +1 more source

Discovery of the α-emitting isotope 210Pa. [PDF]

open access: yesNat Commun
Zhang MM   +37 more
europepmc   +1 more source

Energy dependence of the GAFCHROMIC LD‐V1 in the diagnostic radiographic modalities

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract The GAFCHROMIC LD‐V1 radiochromic film is widely used in dosimetry because it can provide high‐resolution two‐dimensional dose distributions without processing. This study aimed to evaluate the response characteristics at different effective energies, from the low‐energy range of mammography to the high‐energy range of computed tomography. Net
Tatsuhiro Gotanda   +9 more
wiley   +1 more source

Automated rapidplan model validation using Eclipse scripting API

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract RapidPlan offers efficiency gains and quality improvements in treatment planning. Prior to its use in the clinic, it requires an extensive validation procedure in which established clinical plans and those generated by the model are compared. The manual iterative nature of this process is resource intensive, as numerous iterations are required
Bradley Beeksma   +2 more
wiley   +1 more source