Results 121 to 130 of about 1,044,520 (358)

Ptychographic X-ray computed tomography at a high-brilliance X-ray source.

open access: yesOptics Express, 2019
Ptychographic X-ray computed tomography is a phase-contrast imaging technique capable of retrieving three-dimensional maps of the index of refraction of the imaged volumes with nanometric resolution.
S. Sala   +5 more
semanticscholar   +1 more source

Characterization of a prototype rapid kilovoltage x‐ray image guidance system designed for a linear accelerator radiation therapy unit

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study evaluates a novel cone‐beam computed tomography (CBCT) imaging solution integrated onto a conventional C‐arm linear accelerator (linac) with increased gantry speed. The purpose is to assess the impact of improved imaging hardware and reconstruction algorithms on image quality.
Theodore Arsenault   +9 more
wiley   +1 more source

Monte Carlo modeling of radiation dose from radiation therapy with superficial x‐rays

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Introduction Superficial x‐rays (50–100 kVp) are used for treating non‐melanoma skin cancer and intraoperative radiation therapy (IORT). At these energies, the photoelectric effect significantly increases absorbed dose to bone compared to soft tissue.
Reham Barghash   +3 more
wiley   +1 more source

Development of Focused X-ray Luminescence Compute Tomography Imaging [PDF]

open access: yesarXiv
X-ray luminescence is produced when contrast agents absorb energy from X-ray photons and release a portion of that energy by emitting photons in the visible and near-infrared range. X-ray luminescence computed tomography (XLCT) was introduced in the past decade as a hybrid molecular imaging modality combining the merits of both X-ray imaging (high ...
arxiv  

Diagnostic image‐based treatment planning for online adaptive ultra‐hypofractionated prostate cancer radiotherapy with MR‐Linac

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose A new workflow was investigated for Elekta Unity MR‐Linac by removing the computed tomography (CT)‐simulation step and using diagnostic CT (DCT) for reference plan generation. Materials and methods Ten patients with ultra‐hypofractionated prostate cancer treated with magnetic resonance imaging (MRI)‐guided adaptive radiotherapy were ...
Yuan Xu   +5 more
wiley   +1 more source

Randomized Iterative Reconstruction for Sparse View X-ray Computed Tomography [PDF]

open access: yesarXiv, 2017
With the availability of more powerful computers, iterative reconstruction algorithms are the subject of an ongoing work in the design of more efficient reconstruction algorithms for X-ray computed tomography. In this work, we show how two analytical reconstruction algorithms can be improved by correcting the corresponding reconstructions using a ...
arxiv  

A method for measuring spatial resolution based on clinical chest CT sequence images

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study aimed to develop and validate a method for characterizing the spatial resolution of clinical chest computed tomography (CT) sequence images. Methods An algorithm for characterizing spatial resolution based on clinical chest CT sequence images was developed in Matlab (2021b).
Ying Liu   +3 more
wiley   +1 more source

Monte Carlo Simulation for Polychromatic X-ray Fluorescence Computed Tomography with Sheet-Beam Geometry [PDF]

open access: yesarXiv, 2017
X-ray fluorescence computed tomography based on sheet-beam can save a huge amount of time to obtain a whole set of projections using synchrotron. However, it is clearly unpractical for most biomedical research laboratories. In this paper, polychromatic X-ray fluorescence computed tomography with sheet-beam geometry is tested by Monte Carlo simulation ...
arxiv  

BreastWatch: A Varian Eclipse script tool for Community‐Based automatic evaluation of breast treatment plans

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This work introduces BreastWatch, a Varian Eclipse script tool designed to help medical physicists, dosimetrists, and radiation oncologists easily inspect and improve External Beam Breast Treatment (EBBT) plans using automatic evaluation of protocol dose‐constraints enhanced by a Community‐Based approach.
Stefano Agostinelli   +8 more
wiley   +1 more source

X-Ray Computed Tomography Reveals the Response of Root System Architecture to Soil Texture1[OPEN]

open access: yesPlant Physiology, 2016
X-ray computed tomography of rice root system architecture in different substrate textures reveals genotype by environment interactions. Root system architecture (RSA) impacts plant fitness and crop yield by facilitating efficient nutrient and water ...
Eric D. Rogers   +5 more
semanticscholar   +1 more source

Home - About - Disclaimer - Privacy