Results 281 to 290 of about 121,325 (308)
Some of the next articles are maybe not open access.

7 years of X-Ray fluorescence computed micro-tomography

2004
Since 1998 we have developed X-Ray fluorescence tomography for microanalysis. All aspects were tackled starting with the reconstruction performed by FBP or ART methods. Self-absorption corrections were added and combined with Compton, transmission and fluorescence tomographies to obtain fully quantitative results.
Simionovici A   +4 more
openaire   +2 more sources

Characterization of oil nano-structures with monochromatic x-ray micro-tomography

SPIE Proceedings, 2012
Here we report work done toward detection and characterization of micro-and nano-structures in bitumen, including mineral particles-clay and sand as well as metal-organic micro-and nano-structures containing porphyrines. X-ray micro-tomograph with monochromatic radiation has been used for detection of the structures.
Victor E. Asadchikov   +4 more
openaire   +1 more source

X-ray micro-tomography using white beam radiation from SPring-8

Journal of Instrumentation, 2013
An X-ray micro-tomography system using white beam radiation was developed. A flat mirror was used to eliminate X-rays with energies higher than the critical energy of the mirror under the total reflection condition. To enlarge the field of view in the reflected beam, a simple mechanical bender was used to expand the beam in the vertical direction.
M Hoshino, K Uesugi, T Sera, N Yagi
openaire   +1 more source

High Resolution X‐ray Micro‐Tomography of the Posterior Ampullary Nerve

The FASEB Journal, 2018
Introduction The posterior ampullary (singular) nerve runs from the posterior ampulla to the saccular nerve (forming the inferior vestibular nerve) through the singular canal of Morgagni in temporal bone. Posterior ampullary neurectomy can be proposed in a few chronically disabling benign paroxysmal positional ...
Marc LABROUSSE   +6 more
openaire   +1 more source

X-ray Micro-tomography in Food Processing

2021
Azharul Karim   +2 more
openaire   +1 more source

OPTIMIZATION OF X-RAY PHASE-CONTRAST MICRO TOMOGRAPHY FOR VIRTUAL HISTOLOGY

Physica Medica, 2022
Lucía Mariel Arana Peña   +6 more
openaire   +1 more source

Anisotropic wetting on grooved surface observed by X-ray micro tomography

2014
An experimental study of the anisotropic wetting behavior of a surface patterned with parallel grooves is presented. Glycerin droplet shapes, arising from grooves in the order of about 125 um, are investigated by X-ray micro computed tomography acting as a non-intrusive, full volume 3D microscope with micrometric spatial resolution.
SANTINI, Maurizio   +4 more
openaire   +2 more sources

Guidelines for assessment of bone microstructure in rodents using micro–computed tomography

Journal of Bone and Mineral Research, 2010
Mary L Bouxsein   +2 more
exaly  

Issues with implementing a high‐quality lung cancer screening program

Ca-A Cancer Journal for Clinicians, 2014
James L Mulshine
exaly  