This paper evaluates the potential usage of graphene/crosslinked polyethylene (graphene/XLPE) as the insulating material for high voltage direct current (HVDC) cables.
Yuan Li +4 more
doaj +1 more source
Impact of mechanical deformation on space charge in XLPE
In this paper we report the effect of mechanical deformation on space charge dynamics in crosslinked polyethylene. Thin films were peeled from a 66 kV commercial XLPE cable. Space charge measurements under dc electric fields have been monitored using the
Chen, G., Kamaruzzaman, M. R.
core +1 more source
Space Charge Accumulation under Effects of Temperature Gradient and Applied Voltage Reversal on Solid Dielectric DC Cable [PDF]
A well-known fact of the existence and accumulation of space charge within the insulating material poses threat to the reliability in the operation of dc power cables.
Chen, George +2 more
core +1 more source
DC cross-linked polyethylene (XLPE) power cables are being used recently for HV/EHV applications, the reliability of which is claimed to be significantly affected by space charge accumulation in the insulating material.
Zhipeng Lei +8 more
doaj +1 more source
Electric field requirements for charge packet generation and movement in XLPE [PDF]
The formation of space charge packets in XLPE (Cross-linked polyethylene) tapes from unaged cable insulation has been studied utilising the pulsed electro-acoustic (PEA) technique.
Dissado, L. A. +2 more
core +1 more source
Charge distribution and electroluminescence in cross-linked polyethylene under dc field [PDF]
The intent of this paper is to cross-correlate the information obtained by space charge distribution analysis and electroluminescence (EL) detection in cross-linked polyethylene samples submitted to dc fields, with the objective to make a link between ...
A See +22 more
core +1 more source
This study investigated the electric field distribution of underground cable insulation in cross-linked polyethylene/zinc oxide (XLPE/ ZnO) nanoparticles (NPs) for medium-voltage (MV) cables. The ZnO NPs that were obtained by three methods of preparation
A. I. Sharshir +5 more
doaj +1 more source
ABSTRACT A time domain pulse (TDP) based on the frequency domain reflectometry (FDR) method can be used to diagnose the insulation state of cable defects. However, because of the limitations of the FDR test instrument, the lack of a reflection coefficient spectrum (RCS) in the low‐frequency band (LFB) can result in low frequency oscillation in the time
Jingtao Huang +6 more
wiley +1 more source
High-performance cross-linked polyethylene (XLPE) is currently employed in ultra-high-voltage direct current (UHVDC) cables, with the electrical tree being an important cause of DC cable breakdown.
Zhimin Yan +5 more
doaj +1 more source
ABSTRACT Wind energy has become one of the most promising new energy resources. In the construction of offshore wind farms, the cable accounts for about 10% of the total investment, and the optimization of the cable layout is necessary for reducing the total cost of the wind farm. In this paper, we proposed a novel algorithm for the optimization of the
Guoqing Huang +5 more
wiley +1 more source