Results 1 to 10 of about 139,328 (210)

Characterization and health index assessment of 34.5 kV cross-linked polyethylene (XLPE) power cables [PDF]

open access: yesScientific Reports
Degradation of the Cross-Linked Polyethylene (XLPE) insulation impacts the performance of the cable that leading to cable failure and instability of the electrical grid.
Ali Ahmed Salem   +4 more
doaj   +2 more sources

Thermal Effect of Different Laying Modes on Cross-Linked Polyethylene (XLPE) Insulation and a New Estimation on Cable Ampacity

open access: yesEnergies, 2019
This paper verifies the fluctuation on thermal parameters and ampacity of the high-voltage cross-linked polyethylene (XLPE) cables with different insulation conditions and describes the results of a thermal aging experiment on the XLPE insulation with ...
WenWei Zhu   +7 more
doaj   +3 more sources

Criticaltime phenomenon in ageing of XLPE cable insulation and the kinetics modeling

open access: yes电力工程技术, 2023
In order to comprehend the ageing characteristics profoundly and evaluate the ageing degree of cross-linked polyethylene (XLPE) cable insulation, the XLPE cable insulation is subjected to accelerated ageing experiment at 135 oC.
GUO Wei   +5 more
doaj   +1 more source

Influence of structural characteristics on cable ampacity and electrical property for cross-linked polyethylene (XLPE) cable

open access: yesAIP Advances, 2021
The influence of structural characteristics on the cable ampacity and electrical property of the cross-linked polyethylene (XLPE) cable was presented in this paper.
ZhiHui Xu   +3 more
doaj   +1 more source

Chemical Property Evaluation and Tensile Strength Correlation of XLPE Insulators Based on Accelerated Thermal Aging

open access: yesApplied Sciences, 2023
Cross-linked polyethylene (XLPE) cable is a representative power transmission cable. XLPE has excellent mechanical properties, chemical and heat resistance, and insulation.
Byeong Sub Kwak   +6 more
doaj   +1 more source

The Cable Fault Diagnosis for XLPE Cable Based on 1DCNNs-BiLSTM Network

open access: yesJournal of Control Science and Engineering, 2023
Diagnosing the fault type accurately from a variety of faults is very essential to ensure a stable electricity supply when a short-circuit fault occurs. In this paper, a hybrid classification model combining the one-dimensional convolutional neural network (1D-CNN) and the bidirectional long short-term memory network (BiLSTM) is proposed for the ...
Qianyu Wang   +4 more
openaire   +3 more sources

Research and Development of 66 kV Water Tree Retardant XLPE Light Insulated Submarine Cable

open access: yesZhongguo dianli, 2020
This paper introduces the development method of a light submarine cable with rated voltage of 66 kV and water tree retardant cross linked polyethylene insulation(XLPE).
Guo CHEN   +6 more
doaj   +1 more source

Development of 500‐kV XLPE cables

open access: yesElectrical Engineering in Japan, 1996
A 500-kV XLPE insulated cable with an insulation thickness of 27 mm has been developed for long-distance transmission lines. Basic studies on the 500-kV XLPE cable have shown that contaminants in the insulation may determine electrical performance. This hypothesis is justified by the good correlation obtained between statistical estimations of the size
Kenji Kaminaga   +6 more
openaire   +2 more sources

A Study on the Space Charge Characteristics of AC Sliced XLPE Cables

open access: yesIEEE Access, 2019
Cross-linked polyethylene (XLPE) cables are widely used in power systems due to their excellent electrical and mechanical properties. Space charge is an important factor in cable aging and breakdown. At present, XLPE cables in the power system are mainly
Chaofei Gao   +4 more
doaj   +1 more source

Home - About - Disclaimer - Privacy