Results 101 to 110 of about 139,328 (210)
HEAT TESTS OF POWER CABLES WITH XLPE INSULATION AT DIRECT VOLTAGES UP TO 110 KV
In this paper, experiment for determining the temperature difference between the elements of cable and in the open air is considered. The formation of a three cables laid in a plane with different spacing between adjacent cables.
T.Yu. Antonets +2 more
doaj
Thermal ageing is an important factor leading to the deterioration of crosslinked polyethylene (XLPE) cable insulation. In this paper, XLPE insulating material was prepared in the laboratory and treated by thermal ageing at 130°C for durations of up to ...
Bingrong Huang +5 more
doaj +1 more source
Towards a more flexible rating method for cables in tunnels
In recent years the use of cable tunnels in large urban areas has become more popular, with the additional capital cost becoming increasingly acceptable in light of the growing difficulties incurred for large scale directly buried cable installations ...
Payne, D. +4 more
core +1 more source
IDENTIFYING CABLE DISORDERS WITH ON-VOLTAGE TIME DOMAIN REFLECTOMETRY
In this paper a diagnostics technique is presented for localization of degraded regions along a cross-linked polyethylene (XLPE) insulated power cable.
Vincent Onotu FACHE
doaj
Development of HVDC XLPE Cable and Accessories
Yagi, Yukihiro +4 more
openaire +1 more source
The effects of crosslinking byproducts on the electrical properties of low density polyethylene
Crosslinked polyethylene (XLPE) is widely used for high voltage insulation in power transmission systems. However, it has been found that, after crosslinking with Dicumyl Peroxide (DCP), the crosslinking byproducts such as acetophenone, ?-methylstyrene ...
Hussin, Nuriziani
core +1 more source
Study on Deterioration Mechanism of XLPE Cables
K. Kaminaga +5 more
openaire +2 more sources
Overview of Monitoring, Diagnostics, Aging Analysis, and Maintenance Strategies in High-Voltage AC/DC XLPE Cable Systems. [PDF]
Emdadi K +4 more
europepmc +1 more source
Analysis of the deterioration process of DC XLPE cable with protrusion defect based on the development of partial discharge. [PDF]
Zhou Y +5 more
europepmc +1 more source
Condition Monitoring of Power Cables
A National Grid funded research project at Southampton has investigated possible methodologies for data acquisition, transmission and processing that will facilitate on-line continuous monitoring of partial discharges in high voltage polymeric cable ...
Swaffield, D J +3 more
core

