The Network Construction of a New Byproduct-Free XLPE-Based Insulation Using a Click Chemistry-Type Reaction and a Theoretical Study of the Reaction Mechanism. [PDF]
Du Y +8 more
europepmc +1 more source
Cable online partial discharge detection and state evaluation based on deep belief network and swarm intelligence optimization algorithm. [PDF]
Hou Y +6 more
europepmc +1 more source
Phase Selection Method for 10 kV Three-Core Cables Under Single-Phase Grounding Fault Transient Based on Surface Magnetic Field Sensing. [PDF]
Wang H +6 more
europepmc +1 more source
Medium-Voltage AC Cable Joints: A Review of Testing Methods, Standards, and Emerging Trends. [PDF]
Mingotti A +3 more
europepmc +1 more source
Influence of Thermal Aging on Space Charge Characteristics and Electrical Conduction Behavior of Cross-Linked Polyethylene Cable Insulation. [PDF]
Yang J, Li R, Hu L, Wang W.
europepmc +1 more source
Related searches:
Failure Mechanisms in XLPE Cables
2021During the operation of the cables, their insulation is subjected to simultaneous or consecutive electrical, thermal, mechanical and environmental stresses. These stresses contribute to the initiation and development of some processes of XLPE degradation; processes that lead, in time, to the insulation breakdown and, therefore, to the removal and ...
Petru V. Noțingher +2 more
openaire +1 more source
Development Of 275 kV XLPE Cable System And Prospect Of 500 kV XLPE Cable
IEEE Transactions on Power Apparatus and Systems, 1983This paper describes the development of 275 kV XLPE cable and its accessories, and the prospect of 500 kV XLPE cable.
M. Takaoka, M. Ono, I. Kaji
openaire +1 more source
Electroluminescence for XLPE cable diagnosis
Proceedings of the 7th International Conference on Properties and Applications of Dielectric Materials (Cat. No.03CH37417), 2004Electrical treeing is responsible for the breakdown of power cables with polymeric insulation, such as low density polyethylene (LDPE) and cross-linked polyethylene (XLPE). Electroluminescence (EL) occurs in the initiation phase of electrical tree. We studied the characteristics of EL in XLPE cut from 77 kV class power cables.
R. Ishii +4 more
openaire +1 more source
Deterioration in aged XLPE cables
[Proceedings] 1992 Annual Report: Conference on Electrical Insulation and Dielectric Phenomena, 2003Electrical and material characteristics of 93 aged XLPE (cross-linked polyethylene) cables removed from the field after 2 approximately 19 years of service were measured. It was confirmed that breakdown strengths under AC, DC, and impulse voltages in such cables decrease with length of service.
T. Nagata, N. Shimizu
openaire +1 more source
Water measurements in XLPE cables
Conference on Electrical Insulation & Dielectric Phenomena - Annual Report 1985, 1985The water content in buried high-voltage cables is of great industrial interest, especially in view of the treeing observed in crosslinked polyethylene (XLPE) cables in the presence of water (1–3). It is not yet clear, however, if a minimum water content exists above which tree growth is initiated. Although the saturated-water content of PE is about 10–
J. P. Crine +3 more
openaire +1 more source