Results 141 to 150 of about 14,226 (197)
Some of the next articles are maybe not open access.

Ocular Effect of Neodymium-Yag Laser

American Journal of Ophthalmology, 1984
We aimed a high-powered pulsed neodymium-YAG laser incrementally from air to the anterior portion of the vitreous in rabbits to evaluate its effect on the corneal endothelium, the lens, and the dynamics of intraocular fluid. Corneal endothelium damage occurred as much as 3.5 mm away from the site of optical breakdown.
A A, Khodadoust   +3 more
openaire   +2 more sources

Safety of Neodymium-Yag Lasers

American Journal of Ophthalmology, 1983
The neodymium-YAG (yttrium, aluminum, garnet) laser is fundamentally different from the commercially available argon, ruby, carbon dioxide, and krypton lasers. All of those lasers work by the generation of heat because the energy of the laser is absorbed in the form of heat in a tissue. This produces a thermal coagulation of tissue in a focal area. The
openaire   +2 more sources

YAG laser meloplasty and blepharoplasty

Aesthetic Plastic Surgery, 1995
Twenty-eight patients have undergone facelift and blepharoplasty in which the YAG laser scalpel was used. The laser is able to produce an incision with excellent hemostasis. The patients in this series demonstrated markedly diminished blood loss during surgery and reduced bruising, swelling, pain, and discomfort postoperatively.
openaire   +2 more sources

Neodymium-YAG Laser Iridotomy

Journal of the Royal Society of Medicine, 1986
Results of neodymium-YAG laser iridotomy in 34 eyes with narrow drainage angles are reported. Irido-tomies appeared patent on slit-lamp examination in 32 (94%) eyes. Complications included failed patency of iridotomy and acute elevation of intraocular pressure.
openaire   +2 more sources

YAG laser in ophthalmology

SPIE Proceedings, 2002
A summary of using near (Nd) and middle (Er) infrared YAG laser systems in ophthalmology surgery is given in the paper. The report on twelve years of clinical experience with the ophthalmic Nd:YAG laser system (λ=1.06 μm) operating alternatively on Q-switched or mode-locked regimes is accomplished.
Helena Jelinkova   +6 more
openaire   +1 more source

Nd-YAG Laser in Our Experience

Ophthalmologica, 2010
The Authors report on their experience with Microruptor 2, Fankhauser’s YAG laser. Over a period of about 18 months, approximately 500 patients with different pathological conditions of the eye were treated. The treatments were noninvasive and given to outpatients under surface anesthesia. The instrument is suitable for use in cases requiring splitting
C, Balacco-Gabrieli   +3 more
openaire   +2 more sources

Evanescent coupling alternatives for YAG lasers

SPIE Proceedings, 2000
Diffraction gratings are proposed as an alternative technique to couple a laser diode pump beam into the YAG crystal of a solid-state laser. These binary diffraction gratings are on the long axis of the crystal and are etched in high refractive index coating material.
Stiens, Johan   +3 more
openaire   +2 more sources

Q-switching the Erbium-YAG Laser

Journal of Modern Optics, 1994
An erbium-YAG laser has been Q-switched by two methods; a mechanical technique employing a rotating output coupler and electro-optically utilizing a LiNbO3 crystal. The performances of each technique are assessed and compared. Pulse durations of 150 to 850 ns have been produced, with pulse energies of 1 to 16 mJ depending on the technique used.
Wannop, N.M.   +3 more
openaire   +1 more source

Broncholith Removal using the YAG Laser

Chest, 1986
An 85-year-old woman presented with a broncholith in the intermediate bronchus that could not be extracted with either flexible or rigid bronchoscopes. A YAG laser was used to fragment this broncholith so that it could be removed in pieces through a bronchoscope. Chemical composition and morphology of the broncholith were determined.
V M, Miks   +3 more
openaire   +2 more sources

Neodymium-Yag Laser for Posterior Capsulotomy

American Journal of Ophthalmology, 1983
We used the neodymium-YAG laser to perform discission of the posterior capsule in 49 eyes of 47 patients who had undergone previous extracapsular cataract extraction. The visual results were encouraging, with an improvement in visual acuity of one or more Snellen lines in 45 eyes and an improvement of three or more Snellen lines in 33 eyes.
A C, Terry   +3 more
openaire   +2 more sources

Home - About - Disclaimer - Privacy