Results 21 to 30 of about 703,374 (204)
Several thermodynamic properties are crucial in selecting the optimal working fluids and significantly affect the performance of the Organic Rankine cycle (ORC); one of them is the liquid-vapor critical temperature.
Aram M. Ahmed, Attila R. Imre
doaj +1 more source
Characteristics of Organic Rankine Cycles with Zeotropic Mixture for Heat Recovery of Exhaust Gas of Boiler [PDF]
In order to overcome the shortage of pure fluid with constant phase change temperature, zeotropic mixtures were employed to construct the organic Rankine cycle (ORC) system for waste heat recovery of exhaust gas of boiler in coal-fired power plant.
Zhou, Yingyan +4 more
core +1 more source
To solve the problem of low thermal efficiency of the organic Rankine cycle (ORC) and to enhance the coefficient of performance (COP) of ejector refrigeration cycle, an ORC combined with an ejector heat pump-based combined cooling, heat and power system ...
Yaici W., Entchev E., Longo M.
core +1 more source
Performance Analysis of a Novel Double-temperature Chilling Water Unit Using Large Temperature Glide Zeotropic Mixture [PDF]
Accordingly to the properties of zeotropic mixture R32:R236fa, a novel double-temperature chilling water unit was proposal in this paper, this unit can produce two different temperature of chilled water (such as low temperature is 7°C, high temperature ...
Liu, Jian, Zhang, Xiao Song
core +1 more source
Globally there are several viable sources of renewable, low-temperature heat (below 130 °C), particularly solar energy, geothermal energy, and energy generated from industrial wastes.
Wahiba Yaïci +3 more
doaj +1 more source
Consolidation of multiple binary distillation columns for large heat duty savings
ABSTRACT The enormous scales of chemical and petrochemical plants present significant challenges in separating and purifying numerous mixed streams generated within a facility, as well as in achieving effective energy utilization and process intensification.
Parikshit S. Kadu, Rakesh Agrawal
wiley +1 more source
ABSTRACT This study proposes a novel integrated system (SDKC‐DORC) that combines a split‐flow dual‐pressure Kalina cycle with a secondary organic Rankine cycle for the synergistic utilization of solar energy and liquefied natural gas (LNG) cold energy.
Ke Xiao +6 more
wiley +1 more source
Flow Boiling Heat Transfer and Pressure Drop of R1234ze(E) and R32 in a Horizontal Micro-Fin Tube [PDF]
In the present study, the flow boiling heat transfer of R1234ze(E), R32 and zeotropic mixture R1234ze(E)/R32 (50/50 mass%) in a horizontal micro-fin tube is experimentally investigated to clarify the pressure drop and heat transfer characteristics ...
Koyama, Shigeru +2 more
core +1 more source
Experimental investigation of a heat pump tumble dryer with a zeotropic refrigerant mixture [PDF]
Due to their high global warming potential (GWP), fluorinated refrigerants are being replaced in many heat pump and refrigeration systems. Especially in small systems such as heat pump tumble dryers (HPTD), the replacement of the globally used working ...
Hesse, Ulrich +3 more
core +4 more sources
Temperature glide matching in a zeotropic mixture heat pump [PDF]
The use of zeotropic mixtures in heat pumps should lead to a reduction of the exergy losses within the heat exchangers due to the temperature glide (TG) and thus to an improvement of the entire process. In a previous publication (ECOS 2016), the coefficient of performance (COP) as a function of evaporation / condensation temperature, compressor ...
Venzik, Valerius, Atakan, Burak
openaire +3 more sources