Results 1 to 10 of about 241,758 (297)
This paper develops and analyzes a methodology for detecting stator winding inter-turn faults in surface-mounted permanent magnet synchronous motors. The proposed methodology is based on monitoring the zero-sequence voltage component having into account the effects of the inverter that usually feeds the machine.
Julio-Cesar Urresty +2 more
exaly +5 more sources
This paper develops and analyzes an online methodology to detect demagnetization faults in surface-mounted permanent magnet synchronous motors. The proposed methodology, which takes into account the effect of the inverter that feeds the machine, is based on monitoring the zero-sequence voltage component of the stator phase voltages.
Julio-Cesar Urresty +2 more
exaly +5 more sources
A New PWM Control based on an Optimized Zero Sequence Component injection: Application in a Two-Level Inverter [PDF]
In this paper, a new optimization problem is proposed for improvement of PWM control of an inverter that supplies a generic RLE load. Two objectives functions are studied separately: Weighted Total Harmonic Distortion (WTHD) of load voltages and total losses.
Adrien Bourgeade +4 more
exaly +2 more sources
With the continuous penetration and development of renewable energy power generation, distributed grids and microgrids are becoming increasingly important in power systems.
Guoli Feng +4 more
doaj +1 more source
In some key areas, fault-tolerant control is usually needed in order to enable the motor to operate continuously in fault mode. Given that it is difficult to detect the zero-sequence current of the open winding permanent magnet synchronous motor after ...
Kangfei Lv, Xinwei Dong, Cong Zhu
doaj +1 more source
AC Fault Ride-Through Strategy of a Transformerless Soft Normally Open Point
This paper focuses on the soft normally open point (SNOP) which has no transformers and connects to the 10 kV distribution network through the arc suppression coil grounding mode.
Feng Xu +3 more
doaj +1 more source
At present, most of the research on underground power supply system grounding fault positioning in coal mine adopts the transient method, which needs to collect zero sequence voltage and zero sequence current of the line at the same time.
OUYANG Min +10 more
doaj +1 more source
When the overhead line passes through the forest area, the conductor may contact the line to induce the tree-contact single-phase-to-ground fault (TSF), and the persistence of TSF may induce wildfires, bringing serious consequences.
Jianbo He +6 more
doaj +1 more source
Aiming at the issue of zero-sequence current (ZSC) in the dual-inverter fed open-end winding transformer (OEWT-DI) based photovoltaic (PV) grid-tied system with common DC bus, a carrier-based pulse width modulation (CBPWM) strategy with steerable zero ...
Baoji Wang, Xing Zhang, Renxian Cao
doaj +1 more source
We propose a modular multilevel converter (MMC) based three-phase four-wire (3P4W) split capacitor distribution static synchronous compensator (DSTATCOM), aiming at compensating unbalanced and reactive load currents.
Lei Lin, Jialu He, Chen Xu
doaj +1 more source