Geometry of Zero Sequence Components and Fault in The Power System Earthing

2024 IEEE Third International Conference on Power Electronics, Intelligent Control and Energy Systems (ICPEICES)
Tapas Halder
exaly   +2 more sources

Fractionalization of microgrid protection system through detection of zero sequence component of fault current

2016 7th India International Conference on Power Electronics (IICPE), 2016
The fault current at a particular node in microgrid system varies depending upon its grid connected and islanded mode of operations. In this scenario microgrid the function of microgrid central protection unit becomes challenging to maintain its simplicity and reliability during protection coordination.
Manjeet Singh, Prasenjit Basak
openaire   +1 more source

Reference voltage calculation method based on zero-sequence component optimisation for a regional compensation DVR

International Journal of Electronics, 2017
ABSTRACTThis paper describes the design of a dynamic voltage restorer (DVR) that can simultaneously protect several sensitive loads from voltage sags in a region of an MV distribution network. A novel reference voltage calculation method based on zero-sequence voltage optimisation is proposed for this DVR to optimise cost-effectiveness in compensation ...
Le Jian   +3 more
openaire   +1 more source

Directional high-resistance earth fault detector based on zero-sequence components and wavelet transform

2010 IEEE International Conference on Power and Energy, 2010
Distance relays are subject to fail to detect some earth faults since the fault resistance is usually much more in the earth faults rather than the ph-ph faults. Typically a traditional zero-sequence-based method is used to detect a high-resistance earth fault. However, this method fails to detect some high-resistance earth faults.
Amin Samanfar, Behnam Mahamedi
openaire   +1 more source

A DVR Control for Compensating Unbalanced Voltage Dips of a DFIG System using Zero Sequence Components

Journal of the Korean Institute of Illuminating and Electrical Installation Engineers, 2013
The dynamic voltage restorer (DVR) is an effective protection device for wind turbine generators based on doubly-fed induction generator (DFIG) that is operated under unbalanced voltage dip conditions. The compensating voltages of the DVR depend on the voltage dips and on the influence of the zero sequence component. The zero sequence component results
Quach Ngoc Thinh   +3 more
openaire   +1 more source

Online PMSM Stator Interturn Fault Detection Aided by Phase Angle Diagnosis of Zero-sequence Components

2021
Accurate diagnosis of slight inter-turn short circuit fault (ISCF) of permanent magnet synchronous motor (PMSM) has always been a difficult problem in the field of electrical engineering. Aiming at the problem of ineffective ISCF diagnosis, a method on Phase angle diagnosis of zero-sequence components is proposed.
Yecheng Zhang, Gai Liu
openaire   +1 more source

Zero-sequence components in unit-connected generator with ungrounded neutral during ground-faults

PowerCon 2000. 2000 International Conference on Power System Technology. Proceedings (Cat. No.00EX409), 2002
An analysis of voltage zero-sequence components in a generator during normal operation (pre-fault conditions) and during ground-faults in stator winding of generator with ungrounded neutral is presented. The changes in voltage zero-sequence components of fundamental frequency and 3rd harmonic during generator pre-fault conditions, ground-faults in ...
openaire   +1 more source

High Impedance Fault Area Location in Distribution Systems Based on Current Zero Sequence Component

IEEE Latin America Transactions, 2016
This paper presents a new methodology for detection and area location of high impedance faults (HIF) on unbalanced distribution systems. The method is called Quasi-Differential Zero Sequence Protection (PQDSZ) and it detects these faults by analyzing the current zero sequence rms value on a distribution feeder.
J.T.A. Vianna   +2 more
exaly   +2 more sources

High-Resistance Connection Detection in Permanent Magnet Synchronous Machine Using Zero-Sequence Current Component

IEEE Transactions on Power Electronics, 2015
This paper focuses on the development of an online method for diagnosing high-resistance connection (HRC) in delta-connected permanent magnet synchronous machine (PMSM) using zero-sequence current component (ZSCC). The development of this method begins with the establishment of the mathematic model of the PMSM with the HRC.
Jun Hang   +3 more
openaire   +1 more source