A New Fault Line Selection Method Based on Zero-Sequence Active Component
2010 International Conference on Electrical and Control Engineering, 2010a new fault line selection method based on the elimination of unbalanced current of zero-sequence active power is proposed by analyzing the principle of active power method and its inaccuracy. The amplitude and phase of real zero-sequence currents can be calculated by the method and the effect of unbalanced current is eliminated.
Wang Chonglin +3 more
openaire +1 more source
A general SVM algorithm for multilevel converters considering zero-sequence component control
31st Annual Conference of IEEE Industrial Electronics Society, 2005. IECON 2005., 2005Space vector modulation (SVM) scheme plays a significant role in high-voltage high-power applications of multilevel converters for its good performance. This paper presents a novel general SVM algorithm for multilevel converters. It includes two parts: one is control of fundamental component of three-phase outputs corresponding to reference vector; the
null Yongdong Li +2 more
openaire +1 more source
2007 7th International Conference on Power Electronics and Drive Systems, 2007
A minimization problem for the instantaneous active and reactive currents give the optimal solution for the three-wire three-phase systems. This basic solution is simple to implement, but posing practical issues when it is applied to a four-wire three-phase system.
E. Pashajavid +2 more
openaire +1 more source
A minimization problem for the instantaneous active and reactive currents give the optimal solution for the three-wire three-phase systems. This basic solution is simple to implement, but posing practical issues when it is applied to a four-wire three-phase system.
E. Pashajavid +2 more
openaire +1 more source
2016 7th India International Conference on Power Electronics (IICPE), 2016
The fault current at a particular node in microgrid system varies depending upon its grid connected and islanded mode of operations. In this scenario microgrid the function of microgrid central protection unit becomes challenging to maintain its simplicity and reliability during protection coordination.
Manjeet Singh, Prasenjit Basak
openaire +1 more source
The fault current at a particular node in microgrid system varies depending upon its grid connected and islanded mode of operations. In this scenario microgrid the function of microgrid central protection unit becomes challenging to maintain its simplicity and reliability during protection coordination.
Manjeet Singh, Prasenjit Basak
openaire +1 more source
International Journal of Electronics, 2017
ABSTRACTThis paper describes the design of a dynamic voltage restorer (DVR) that can simultaneously protect several sensitive loads from voltage sags in a region of an MV distribution network. A novel reference voltage calculation method based on zero-sequence voltage optimisation is proposed for this DVR to optimise cost-effectiveness in compensation ...
Le Jian +3 more
openaire +1 more source
ABSTRACTThis paper describes the design of a dynamic voltage restorer (DVR) that can simultaneously protect several sensitive loads from voltage sags in a region of an MV distribution network. A novel reference voltage calculation method based on zero-sequence voltage optimisation is proposed for this DVR to optimise cost-effectiveness in compensation ...
Le Jian +3 more
openaire +1 more source
2010 IEEE International Conference on Power and Energy, 2010
Distance relays are subject to fail to detect some earth faults since the fault resistance is usually much more in the earth faults rather than the ph-ph faults. Typically a traditional zero-sequence-based method is used to detect a high-resistance earth fault. However, this method fails to detect some high-resistance earth faults.
Amin Samanfar, Behnam Mahamedi
openaire +1 more source
Distance relays are subject to fail to detect some earth faults since the fault resistance is usually much more in the earth faults rather than the ph-ph faults. Typically a traditional zero-sequence-based method is used to detect a high-resistance earth fault. However, this method fails to detect some high-resistance earth faults.
Amin Samanfar, Behnam Mahamedi
openaire +1 more source
Journal of the Korean Institute of Illuminating and Electrical Installation Engineers, 2013
The dynamic voltage restorer (DVR) is an effective protection device for wind turbine generators based on doubly-fed induction generator (DFIG) that is operated under unbalanced voltage dip conditions. The compensating voltages of the DVR depend on the voltage dips and on the influence of the zero sequence component. The zero sequence component results
Quach Ngoc Thinh +3 more
openaire +1 more source
The dynamic voltage restorer (DVR) is an effective protection device for wind turbine generators based on doubly-fed induction generator (DFIG) that is operated under unbalanced voltage dip conditions. The compensating voltages of the DVR depend on the voltage dips and on the influence of the zero sequence component. The zero sequence component results
Quach Ngoc Thinh +3 more
openaire +1 more source
Torque Improvement of Dual Three-Phase Permanent Magnet Machine Using Zero Sequence Components
IEEE Transactions on Magnetics, 2017This paper investigates the interaction of the zero sequence component into both permanent magnet (PM) shape and phase current to improve the output torque in dual three-phase surface-mounted PM (SPM) machines. The optimal zero sequence components are analytically derived and validated by finite element (FE) analyses.
K. Wang +4 more
openaire +1 more source
2021
Accurate diagnosis of slight inter-turn short circuit fault (ISCF) of permanent magnet synchronous motor (PMSM) has always been a difficult problem in the field of electrical engineering. Aiming at the problem of ineffective ISCF diagnosis, a method on Phase angle diagnosis of zero-sequence components is proposed.
Yecheng Zhang, Gai Liu
openaire +1 more source
Accurate diagnosis of slight inter-turn short circuit fault (ISCF) of permanent magnet synchronous motor (PMSM) has always been a difficult problem in the field of electrical engineering. Aiming at the problem of ineffective ISCF diagnosis, a method on Phase angle diagnosis of zero-sequence components is proposed.
Yecheng Zhang, Gai Liu
openaire +1 more source
Zero-sequence components in unit-connected generator with ungrounded neutral during ground-faults
PowerCon 2000. 2000 International Conference on Power System Technology. Proceedings (Cat. No.00EX409), 2002An analysis of voltage zero-sequence components in a generator during normal operation (pre-fault conditions) and during ground-faults in stator winding of generator with ungrounded neutral is presented. The changes in voltage zero-sequence components of fundamental frequency and 3rd harmonic during generator pre-fault conditions, ground-faults in ...
openaire +1 more source