Zero-sequence components in unit-connected generator with ungrounded neutral during ground-faults
PowerCon 2000. 2000 International Conference on Power System Technology. Proceedings (Cat. No.00EX409), 2002An analysis of voltage zero-sequence components in a generator during normal operation (pre-fault conditions) and during ground-faults in stator winding of generator with ungrounded neutral is presented. The changes in voltage zero-sequence components of fundamental frequency and 3rd harmonic during generator pre-fault conditions, ground-faults in ...
openaire +1 more source
Journal of the Korean Institute of Illuminating and Electrical Installation Engineers, 2013
The dynamic voltage restorer (DVR) is an effective protection device for wind turbine generators based on doubly-fed induction generator (DFIG) that is operated under unbalanced voltage dip conditions. The compensating voltages of the DVR depend on the voltage dips and on the influence of the zero sequence component. The zero sequence component results
Quach Ngoc Thinh +3 more
openaire +1 more source
The dynamic voltage restorer (DVR) is an effective protection device for wind turbine generators based on doubly-fed induction generator (DFIG) that is operated under unbalanced voltage dip conditions. The compensating voltages of the DVR depend on the voltage dips and on the influence of the zero sequence component. The zero sequence component results
Quach Ngoc Thinh +3 more
openaire +1 more source
2014 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC), 2014
Transformers neutral grounding accessing small reactance is an effective measure to restrain short circuit current in 500kV power grid. But accessing small reactance will bring changes to the zero-sequence parameters of system. The relay protection, especially the main transformer protection and transmission line protection nearby will be affected and ...
Li Xiao-hua +4 more
openaire +1 more source
Transformers neutral grounding accessing small reactance is an effective measure to restrain short circuit current in 500kV power grid. But accessing small reactance will bring changes to the zero-sequence parameters of system. The relay protection, especially the main transformer protection and transmission line protection nearby will be affected and ...
Li Xiao-hua +4 more
openaire +1 more source
Zero-Sequence Fault Diagnosis and Wave Recording System Based on Transient Components Analysis
2022 2nd International Conference on Intelligent Technology and Embedded Systems (ICITES), 2022Jian Shen +5 more
openaire +1 more source
An Area-Minimum Control Method Using Zero-Sequence Components and Current Deviation Term for Hvdc
SSRN Electronic Journal, 2022Juanjuan WANG +6 more
openaire +1 more source
2022 4th Asia Energy and Electrical Engineering Symposium (AEEES), 2022
Tao Yan +4 more
openaire +1 more source
Tao Yan +4 more
openaire +1 more source
End Component or Zero-Sequence Reactance of A-C Machines
Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems, 1960openaire +1 more source
2023 IEEE IAS Petroleum and Chemical Industry Technical Conference (PCIC), 2023
Lorrane P. S. Carmo +3 more
openaire +1 more source
Lorrane P. S. Carmo +3 more
openaire +1 more source