A novel method for preventing mal-operation of the zero-sequence directional component
12th IET International Conference on AC and DC Power Transmission (ACDC 2016), 2016Zero-sequence directional components of the healthy line would incorrectly discriminate the fault direction, causing mal-operation of the pilot zero-sequence directional protection, due to the influence of mutual inductance between lines under weak current and strong magnetic situations.
H.Y. Xu +4 more
openaire +1 more source
Torque Improvement of Dual Three-Phase Permanent Magnet Machine Using Zero Sequence Components
IEEE Transactions on Magnetics, 2017This paper investigates the interaction of the zero sequence component into both permanent magnet (PM) shape and phase current to improve the output torque in dual three-phase surface-mounted PM (SPM) machines. The optimal zero sequence components are analytically derived and validated by finite element (FE) analyses.
K. Wang +4 more
openaire +1 more source
IEEE Transactions on Power Electronics, 2015
This paper focuses on the development of an online method for diagnosing high-resistance connection (HRC) in delta-connected permanent magnet synchronous machine (PMSM) using zero-sequence current component (ZSCC). The development of this method begins with the establishment of the mathematic model of the PMSM with the HRC.
Jun Hang +3 more
openaire +1 more source
This paper focuses on the development of an online method for diagnosing high-resistance connection (HRC) in delta-connected permanent magnet synchronous machine (PMSM) using zero-sequence current component (ZSCC). The development of this method begins with the establishment of the mathematic model of the PMSM with the HRC.
Jun Hang +3 more
openaire +1 more source
2016 7th India International Conference on Power Electronics (IICPE), 2016
The fault current at a particular node in microgrid system varies depending upon its grid connected and islanded mode of operations. In this scenario microgrid the function of microgrid central protection unit becomes challenging to maintain its simplicity and reliability during protection coordination.
Manjeet Singh, Prasenjit Basak
openaire +1 more source
The fault current at a particular node in microgrid system varies depending upon its grid connected and islanded mode of operations. In this scenario microgrid the function of microgrid central protection unit becomes challenging to maintain its simplicity and reliability during protection coordination.
Manjeet Singh, Prasenjit Basak
openaire +1 more source
2007 7th International Conference on Power Electronics and Drive Systems, 2007
A minimization problem for the instantaneous active and reactive currents give the optimal solution for the three-wire three-phase systems. This basic solution is simple to implement, but posing practical issues when it is applied to a four-wire three-phase system.
E. Pashajavid +2 more
openaire +1 more source
A minimization problem for the instantaneous active and reactive currents give the optimal solution for the three-wire three-phase systems. This basic solution is simple to implement, but posing practical issues when it is applied to a four-wire three-phase system.
E. Pashajavid +2 more
openaire +1 more source
High Impedance Fault Area Location in Distribution Systems Based on Current Zero Sequence Component
IEEE Latin America Transactions, 2016This paper presents a new methodology for detection and area location of high impedance faults (HIF) on unbalanced distribution systems. The method is called Quasi-Differential Zero Sequence Protection (PQDSZ) and it detects these faults by analyzing the current zero sequence rms value on a distribution feeder.
J.T.A. Vianna +2 more
openaire +1 more source
2010 IEEE International Conference on Power and Energy, 2010
Distance relays are subject to fail to detect some earth faults since the fault resistance is usually much more in the earth faults rather than the ph-ph faults. Typically a traditional zero-sequence-based method is used to detect a high-resistance earth fault. However, this method fails to detect some high-resistance earth faults.
Amin Samanfar, Behnam Mahamedi
openaire +1 more source
Distance relays are subject to fail to detect some earth faults since the fault resistance is usually much more in the earth faults rather than the ph-ph faults. Typically a traditional zero-sequence-based method is used to detect a high-resistance earth fault. However, this method fails to detect some high-resistance earth faults.
Amin Samanfar, Behnam Mahamedi
openaire +1 more source
A Unified SVM Algorithm for Multilevel Converter and Analysis of Zero Sequence Voltage Components
IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics, 2006Space vector modulation (SVM) is widely used in three phase converters. This paper presents a novel SVM algorithm in three phase coordinate system which is very simple to implement. In this algorithm, the role of the zero sequence component in SVM is studied, and the switching states and duty ratios are calculated straightforwardly without vector ...
Wang Chenchen, null Li Yongdong, Xiao Xi
openaire +1 more source
International Journal of Electronics, 2017
ABSTRACTThis paper describes the design of a dynamic voltage restorer (DVR) that can simultaneously protect several sensitive loads from voltage sags in a region of an MV distribution network. A novel reference voltage calculation method based on zero-sequence voltage optimisation is proposed for this DVR to optimise cost-effectiveness in compensation ...
Le Jian +3 more
openaire +1 more source
ABSTRACTThis paper describes the design of a dynamic voltage restorer (DVR) that can simultaneously protect several sensitive loads from voltage sags in a region of an MV distribution network. A novel reference voltage calculation method based on zero-sequence voltage optimisation is proposed for this DVR to optimise cost-effectiveness in compensation ...
Le Jian +3 more
openaire +1 more source
Zero-sequence components in unit-connected generator with ungrounded neutral during ground-faults
PowerCon 2000. 2000 International Conference on Power System Technology. Proceedings (Cat. No.00EX409), 2002An analysis of voltage zero-sequence components in a generator during normal operation (pre-fault conditions) and during ground-faults in stator winding of generator with ungrounded neutral is presented. The changes in voltage zero-sequence components of fundamental frequency and 3rd harmonic during generator pre-fault conditions, ground-faults in ...
openaire +1 more source