Results 31 to 40 of about 1,151,086 (296)

Induction Motor Fault Diagnosis Based on Zero-Sequence Current Analysis

open access: yesEnergies, 2020
This paper presents some considerations regarding the application of the stator zero-sequence current component (ZSC) in the fault detection of cage induction machines, including the effects of magnetic core saturation.
Arkadiusz Duda, Piotr Drozdowski
doaj   +1 more source

Analysis of two-phase operation characteristics of a flexible low-frequency transmission system

open access: yesZhejiang dianli, 2022
The two-phase operation mode of a flexible low-frequency transmission system is based on the M3C (modular multilevel matrix converter). This paper establishes a complex sequence network for the low-frequency system to analyze the steady-state operation ...
LU Yi   +6 more
doaj   +1 more source

On the Neutrino Distributions in Phase Space for the Rotating Core-collapse Supernova Simulated with a Boltzmann-neutrino-radiation-hydrodynamics Code [PDF]

open access: yes, 2019
With the Boltzmann-radiation-hydrodynamics code, which we have developed to solve numerically the Boltzmann equations for neutrino transfer, the Newtonian hydrodynamics equations, and the Newtonian self-gravity simultaneously and consistently, we ...
Furusawa, Shun   +7 more
core   +3 more sources

Smart Power Grid Synchronization With Fault Tolerant Nonlinear Estimation [PDF]

open access: yes, 2016
Effective real-time state estimation is essential for smart grid synchronization, as electricity demand continues to grow, and renewable energy resources increase their penetration into the grid.
Wang, Xin, Yaz, Edwin E
core   +2 more sources

Research on a Faulty Line Selection Method Based on the Zero-Sequence Disturbance Power of Resonant Grounded Distribution Networks

open access: yesEnergies, 2019
For fast and accurate faulty line selection (FLS) in single phase-to-ground (SPG) faults for resonant grounded distribution networks (RGDNs), this paper proposes a FLS method based on zero-sequence power characteristics.
Wenquan Shao   +4 more
doaj   +1 more source

An improved Hausdorff distance method for locating single phase to ground fault in neutral non‐effectively grounded system

open access: yesIET Generation, Transmission & Distribution, 2021
Neutral non‐effectively grounded mode is widely used in medium‐voltage distribution networks in China. When a single‐phase grounding fault occurs in distribution networks, abundant transient signals will be generated.
Wenhao Wu   +4 more
doaj   +1 more source

Particle-hole symmetry and bifurcating ground-state manifold in the quantum Hall ferromagnetic states of multilayer graphene [PDF]

open access: yes, 2013
The orbital structure of the quantum Hall ferromagnetic states in the zero-energy Landau level in chiral multilayer graphene (AB, ABC, ABCA, etc. stackings) is determined by the exchange interaction with all levels, including deep-lying states in the ...
Csaba Tőke, S. M. Girvin
core   +2 more sources

Conserved structural motifs in PAS, LOV, and CRY proteins regulate circadian rhythms and are therapeutic targets

open access: yesFEBS Letters, EarlyView.
Cryptochrome and PAS/LOV proteins play intricate roles in circadian clocks where they act as both sensors and mediators of protein–protein interactions. Their ubiquitous presence in signaling networks has positioned them as targets for small‐molecule therapeutics. This review provides a structural introduction to these protein families.
Eric D. Brinckman   +2 more
wiley   +1 more source

GENERAL FAULT ADMITTANCE METHOD LINETO- LINE-TO-LINE UNSYMMETRICAL FAULT [PDF]

open access: yesJournal of Engineering Science and Technology, 2015
Line-to-line-to-line unsymmetrical faults either involving or not involving ground are in the classical fault analysis approach difficult to analyse.
J. D. SAKALA, J. S. J. DAKA
doaj  

Research on fault line selection method of mine power network

open access: yesGong-kuang zidonghua, 2018
In view of characteristics of DC component of transient zero-sequence current in fault lines is larger than that of normal lines when additional DC source system of mine power network occurrs single-phase earth fault, a fault line selection method of ...
LI Ke   +5 more
doaj   +1 more source

Home - About - Disclaimer - Privacy