With the continuous penetration and development of renewable energy power generation, distributed grids and microgrids are becoming increasingly important in power systems.
Guoli Feng +4 more
doaj +1 more source
In some key areas, fault-tolerant control is usually needed in order to enable the motor to operate continuously in fault mode. Given that it is difficult to detect the zero-sequence current of the open winding permanent magnet synchronous motor after ...
Kangfei Lv, Xinwei Dong, Cong Zhu
doaj +1 more source
AC Fault Ride-Through Strategy of a Transformerless Soft Normally Open Point
This paper focuses on the soft normally open point (SNOP) which has no transformers and connects to the 10 kV distribution network through the arc suppression coil grounding mode.
Feng Xu +3 more
doaj +1 more source
A New PWM Control based on an Optimized Zero Sequence Component injection: Application in a Two-Level Inverter [PDF]
In this paper, a new optimization problem is proposed for improvement of PWM control of an inverter that supplies a generic RLE load. Two objectives functions are studied separately: Weighted Total Harmonic Distortion (WTHD) of load voltages and total losses.
Adrien Bourgeade +4 more
openaire +2 more sources
Aiming at the issue of zero-sequence current (ZSC) in the dual-inverter fed open-end winding transformer (OEWT-DI) based photovoltaic (PV) grid-tied system with common DC bus, a carrier-based pulse width modulation (CBPWM) strategy with steerable zero ...
Baoji Wang, Xing Zhang, Renxian Cao
doaj +1 more source
When the overhead line passes through the forest area, the conductor may contact the line to induce the tree-contact single-phase-to-ground fault (TSF), and the persistence of TSF may induce wildfires, bringing serious consequences.
Jianbo He +6 more
doaj +1 more source
We propose a modular multilevel converter (MMC) based three-phase four-wire (3P4W) split capacitor distribution static synchronous compensator (DSTATCOM), aiming at compensating unbalanced and reactive load currents.
Lei Lin, Jialu He, Chen Xu
doaj +1 more source
INSTABILITY PROBLEM OF CONVENTIONAL TRANSFORMER DIFFERENTIAL PROTECTION-APPLICATION OF ZERO SEQUENCE CURRENT TRAP [PDF]
Zero sequence component of current usually causes instability of the differential protection. It enters circuits through earthed terminals. The traditional way of solving the problem in differential schemes is by connecting the interposing current ...
Ezechukwu O A., O A., Ezechukwu
core +1 more source
Assessment of asymmetry parameters for zero sequence component in the medium voltage network [PDF]
W pracy wyprowadzono parametryczne zależności pozwalające szacować wielkości charakteryzujące asymetrię napięcia, prądów, mocy i admitancji dla podstawowej i wyższych harmonicznych składowych symetrycznych zerowych.
Marciniak, Lubomir
core +1 more source
The compact design is suitable for the urban areas with intensive loads. The flexible multistate switch (FMS) can effectively reduce the footprint by removing transformers, which is the development trend of the flexible AC distribution equipment.
Feng Xu +5 more