Results 231 to 240 of about 500,664 (278)
Some of the next articles are maybe not open access.
Torque Improvement of Dual Three-Phase Permanent Magnet Machine Using Zero Sequence Components
IEEE Transactions on Magnetics, 2017This paper investigates the interaction of the zero sequence component into both permanent magnet (PM) shape and phase current to improve the output torque in dual three-phase surface-mounted PM (SPM) machines. The optimal zero sequence components are analytically derived and validated by finite element (FE) analyses.
Z Q Zhu, Kai Wang, H Y Sun
exaly +2 more sources
2024 International Russian Automation Conference (RusAutoCon)
Nadezhda Malysheva +2 more
exaly +2 more sources
Nadezhda Malysheva +2 more
exaly +2 more sources
IEEE transactions on industrial electronics (1982. Print), 2022
In this article, a new zero-sequence current suppression technique for electrical machine emulators with reduced component count is proposed. The proposed control scheme is implemented by properly regulating the zero states in space vector modulation ...
G. Mademlis +3 more
semanticscholar +1 more source
In this article, a new zero-sequence current suppression technique for electrical machine emulators with reduced component count is proposed. The proposed control scheme is implemented by properly regulating the zero states in space vector modulation ...
G. Mademlis +3 more
semanticscholar +1 more source
The control and analysis of zero sequence components in DVR system
2001 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.01CH37194), 2002The magnitudes and phases of the compensating voltages in a dynamic voltage restorer (DVR) system depend on the voltage sag in the phases affected by the fault and on the influence of the zero sequence components. If the delta connection of the transformer is used, the zero sequence components do not appear on the load side. But nowadays, wye connected
null Il-Yop Chung +3 more
openaire +1 more source
An Analytical Zero Sequence Method to Locate Fault in Distribution Systems Rich in DG
IEEE Transactions on Smart Grid, 2022Locating high impedance faults (HIF) in a distribution system increases the system’s reliability and improves the service’s quality for customers.
D. Penido +3 more
semanticscholar +1 more source
A novel method for preventing mal-operation of the zero-sequence directional component
12th IET International Conference on AC and DC Power Transmission (ACDC 2016), 2016Zero-sequence directional components of the healthy line would incorrectly discriminate the fault direction, causing mal-operation of the pilot zero-sequence directional protection, due to the influence of mutual inductance between lines under weak current and strong magnetic situations.
H.Y. Xu +4 more
openaire +1 more source
2021 IEEE 5th Conference on Energy Internet and Energy System Integration (EI2), 2021
The parallel inverter system with common AC and DC bus has the advantages of small size, low cost and high reliability. However, due to the inconsistency of switch status and main circuit parameters, zero sequence circulating current will be generated ...
Guanjun Li, Haojie Yu, Zhao Liu
semanticscholar +1 more source
The parallel inverter system with common AC and DC bus has the advantages of small size, low cost and high reliability. However, due to the inconsistency of switch status and main circuit parameters, zero sequence circulating current will be generated ...
Guanjun Li, Haojie Yu, Zhao Liu
semanticscholar +1 more source
IEEE transactions on industry applications, 2021
This article aimed to simplify magnetically levitated motor system by implementing the voltage sensorless control of the split capacitor potential for a three-phase four-wire motor system with a zero-sequence suspension winding.
Y. Fujii, J. Asama, A. Chiba
semanticscholar +1 more source
This article aimed to simplify magnetically levitated motor system by implementing the voltage sensorless control of the split capacitor potential for a three-phase four-wire motor system with a zero-sequence suspension winding.
Y. Fujii, J. Asama, A. Chiba
semanticscholar +1 more source
Three-phase sigma-delta modulation using zero-sequence components
2005 European Conference on Power Electronics and Applications, 2005This paper presents new analytic results on the performance of sigma-delta modulated (SDM) three-phase voltage source inverters, in terms of harmonic distortion of output current, conduction and switching losses of the inverter devices, and rms current of the DC link capacitor. The results are compared with the same magnitudes for PWM.
A. Mertens, V. Ganesan
openaire +1 more source
IEEE Transactions on Transportation Electrification
The single-stage dual-port inverter (SSDPI)-fed motor drive is a high-efficiency configuration for hybrid electric vehicles (EVs). However, the modulation design for the SSDPI is a challenging task since the flexible power distribution between dc-port ...
Kehan Luo +4 more
semanticscholar +1 more source
The single-stage dual-port inverter (SSDPI)-fed motor drive is a high-efficiency configuration for hybrid electric vehicles (EVs). However, the modulation design for the SSDPI is a challenging task since the flexible power distribution between dc-port ...
Kehan Luo +4 more
semanticscholar +1 more source

