Results 131 to 140 of about 532,990 (304)

Numerical analysis of switching performance evaluators in low-voltage switching devices

open access: yes, 2015
An arc modelling is a valuable and useful tool to evaluate the switching performance of low-voltage switching devices (LVSDs) during breaking operation before testing real products. Moreover, it helps improve interruption capability of LVSDs and optimize
Golosnoy, I.O., McBride, J.W., Shin, D.
core  

Coating Artificial Spider Silk Fiber with Magnetic FeCo: An Effective Strategy for Creating a Flexible Magneto‐Responsive Material

open access: yesAdvanced Functional Materials, EarlyView.
An original method is presented for producing artificial spider silk fibers with magnetic and magnetomechanical responsiveness, which consists in coating them with a nanometer‐thick layer of FeCo alloy by sputtering deposition. The challenge of combining organic materials and inorganic magnetic nanostructures is addressed, thus taking a step forward ...
Filippo Lanaro   +5 more
wiley   +1 more source

A New Zero Current Switching Ultra Step-Up Converter With Low Input Current Ripple

open access: yesIET Circuits, Devices and Systems
This paper proposes a high step-up converter featuring zero current (ZC) switching (ZCS) and continuous input current to enhance efficiency. The converter integrates switched capacitor and coupled inductor techniques to improve voltage gain while ...
Eiraj Rezai, Majid Delshad, Bahador Fani
doaj   +1 more source

Solution‐Processed Two‐Dimensional Indium Oxide on Sodium‐Embedded Alumina for Reconfigurable Optoelectronic Synaptic Transistors

open access: yesAdvanced Functional Materials, EarlyView.
Wafer‐scale two‐dimensioanl In2Se3 oxidized into InOx on sodium‐embedded beta‐alumina enables multifunctional reconfigurable electronics. Sodium ions accumulate within distinct spatial distribution under drain‐controlle and gate‐controlled operation. Drain‐control operation gives controllability of ultraviolet‐driven optoelectronic synaptic conductance
Jinhong Min   +13 more
wiley   +1 more source

System and component design and test of a 10 hp, 18,000 rpm AC dynamometer utilizing a high frequency AC voltage link, part 1 [PDF]

open access: yes
Hard and soft switching test results conducted with one of the samples of first generation MOS-controlled thyristor (MCTs) and similar test results with several different samples of second generation MCT's are reported.
Alan, Irfan, Lipo, Thomas A.
core   +1 more source

Understanding the Effects of Conductive Polymer Electrode Coating on Recorded Neural Signals

open access: yesAdvanced Healthcare Materials, EarlyView.
Conductive polymer coatings are widely explored to improve the quality of signals recorded with chronically implanted neural electrodes, offering enhanced biocompatibility along with reduced electrode impedance. Combining computational modelling and data from PEDOT:PTS coated and PtIr electrodes in rats, we show that improvements in signal quality with
Karthik Sridhar   +4 more
wiley   +1 more source

A soft switching non‐isolated bidirectional DC–DC converter with improved voltage conversion ratio and minimum number of switches

open access: yesIET Renewable Power Generation
A soft switching non‐isolated bidirectional DC–DC converter with an improved voltage conversion ratio without any additional auxiliary switch is presented in this paper. In the proposed converter, improved step‐up/step‐down gain conversion is achieved by
Nasrin Asadi Madiseh, Ehsan Adib
doaj   +1 more source

Advanced 3D Platforms for Modeling CNS Neuroinflammation: Cell Integration, Techniques, and Challenges

open access: yesAdvanced Healthcare Materials, EarlyView.
This review summarizes the roles of key central nervous system cell types, the extracellular matrix, and the blood‐brain barrier in neuroinflammation, and their integration into diverse 3D culture systems. It examines major incorporation strategies, including direct co‐culture, hydrogel encapsulation, transwell migration assays, and bioprinting ...
Emmanuelle D. Aiyegbusi   +2 more
wiley   +1 more source

Controllable Dynamic Mechanical Cell Stimulation using Magnetically Actuated Artificial Cilia

open access: yesAdvanced Healthcare Materials, EarlyView.
This paper introduces a platform based on magnetic artificial cilia for providing controllable dynamic mechanical stimulation to single cells, suitable for investigating large cell populations and enabling live cell imaging. Proof‐of‐principle experiments show that cell morphology is strongly influenced by the artificial cilia, that cellular forces can
Roel Kooi   +5 more
wiley   +1 more source

A Wide Input Voltage Range Unidirectional Resonant Switched‐Capacitor Converter for Fuel Cell Applications

open access: yesIET Power Electronics
This paper introduces a full bridge high voltage gain resonant switched capacitor converter (SCC) providing soft switching conditions for all power semiconductors above and below the resonant frequencies.
Sajad Afshar Zarandi   +2 more
doaj   +1 more source

Home - About - Disclaimer - Privacy