Results 161 to 170 of about 425,748 (301)

Generalized pairwise z-complementary codes

open access: yes, 2008
An approach to generate generalized pairwise Z-complementary (GPZ) codes, which works in pairs in order to offer a zero correlation zone (ZCZ) in the vicinity of zero phase shift and fit extremely well in power efficient quadrature carrier modems, is ...
Loo, KK, Fan, P, Tung, X, Feng, L
core  

Frequency Response Testing of Zero-Sequence Current Transformers for Mining Ground Fault Protection Relays

open access: yes, 2020
In Polish coal mining, medium voltage power distribution networks operate with an insulated neutral point. Zero-sequence current transformers are the basic sensors that generate input signals for earth-fault protection relays.
Kuliński, Krzysztof, Heyduk, Adam
core  

A Numerical–Experimental Approach for Multi‐Matrix Fiber‐Reinforced Plastics Characterization Using Finite Element Model Updating

open access: yesAdvanced Engineering Materials, EarlyView.
A numerical–experimental framework is developed for characterizing multi‐matrix fiber‐reinforced polymers (MM‐FRPs) combining epoxy and polyurethane matrices. Harmonic bending tests are integrated with finite element model updating (FEMU) to simultaneously identify elastic and viscoelastic material parameters.
Rodrigo M. Dartora   +4 more
wiley   +1 more source

Tailored Hierarchical Porous Copper Architectures via Three Dimensional Printing and Pressure‐less Sintering for Next‐Generation Lithium‐Metal Batteries

open access: yesAdvanced Engineering Materials, EarlyView.
A hierarchical porous copper current collector is fabricated via three‐dimensional printing combined with pressureless sintering to stabilize lithium metal anodes. The interconnected architecture lowers local current density, guides uniform Li deposition within pores, and suppresses dendrite growth.
Alok Kumar Mishra, Mukul Shukla
wiley   +1 more source

Phase-to-phase power balance control in flexible interconnection equipment by injecting zero sequence voltage

open access: yes
The multi terminal flexible interconnection equipment with cascaded full bridge and dual active bridge structure could connect AC power grid and multiple DC power grid, and instantaneous power differences in different DC power grids and sub module faults
JI Ziyue   +4 more
core   +1 more source

Rafting of Ni‐Based Superalloys Under Multiaxial Load as Understood by Phase‐Field Simulations and Critical Experiments

open access: yesAdvanced Engineering Materials, EarlyView.
Phase‐field simulations coupled with dislocation‐density‐based crystal plasticity modeling reproduce γ′ rafting behavior in single‐crystal Ni‐based superalloys under varied loading conditions. The model captures both macroscopic creep and microscopic morphology evolution, with results matching high‐temperature creep experiments.
Micheal Younan   +5 more
wiley   +1 more source

Time‐Dependent Oxidation and Scale Evolution of a Wrought Co/Ni‐Based Superalloy

open access: yesAdvanced Engineering Materials, EarlyView.
This study shows how a new wrought Co/Ni‐based superalloy resists oxidation at 800 ∘$^\circ$C. The oxide scale changes from rough, fast‐growing spinel to a dense, protective chromia–alumina layer. Atom probe analysis reveals tiny refractory‐rich bubbles at the interface that mark the transition to long‐term, diffusion‐controlled protection ...
Cameron Crabb   +6 more
wiley   +1 more source

ZERO-INTERPOLATING SEQUENCES

open access: yesKyushu Journal of Mathematics, 2016
TUGORES, Francesc, TUGORES, Laia
openaire   +2 more sources

Karl Popper and the Mechanisms of Hydrogen Embrittlement

open access: yesAdvanced Engineering Materials, EarlyView.
Representation of the beginning of loss of ductility rather than embrittlement. Small concentrations of hydrogen in a diffusible form within iron are well‐established to harm the mechanical integrity of steels. There are theories that attempt to explain the pernicious role of hydrogen.
H. K. D. H. Bhadeshia
wiley   +1 more source

Direction Method in Compensated Network using the Zero Sequence Active Energy Signal

open access: yes, 2013
In medium voltage distribution network, a coil might be placed in the transformer neutral to compensate the zero sequence capacitance of the network. This creates a zero sequence system with very high impedance fault. In case of single phase earth fault,
Werben, Stefan   +3 more
core  