Results 51 to 60 of about 11,980 (262)

Effect of sterilization by gamma radiation on nano-mechanical properties of teeth [PDF]

open access: yes, 2008
NOTICE: this is the author’s version of a work that was accepted for publication in Dental Materials. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms ...
Brauer, DS   +4 more
core   +1 more source

Temporal dynamics of co‐inoculation of Leptosphaeria maculans and Leptosphaeria biglobosa determine interspecific competition and disease development on oilseed rape

open access: yesPest Management Science, EarlyView.
This study provides evidence that the timing of co‐inoculation of Leptosphaeria maculans and Leptosphaeria biglobosa determine the outcome of interspecific competition and disease development on their host oilseed rape. Abstract BACKGROUND Phoma stem canker is one of the most economically damaging diseases of oilseed rape, caused by co‐existing fungal ...
Evren Bingol   +5 more
wiley   +1 more source

Accuracy and precision of an intraoral scanner in complex prosthetic rehabilitations: an in vitro study [PDF]

open access: yes, 2017
The main purpose of this study is to measure the accuracy and the precision of the intraoral optical scanner CS3500® (Carestream Dental LLC, Atlanta, USA) in complex clinical situations as full arch rehabilitations on impl ants.
BRAUNER, EDOARDO   +5 more
core  

Fracture toughness of zirconia ceramic crowns made by feather-edge tooth preparation design [PDF]

open access: yes, 2012
Background/Aim. Fracture toughness determines functional crown strenght and prevents damages on ceramics during mastication. There is a lack of relevant literature data about fracture toughness of crowns made by feather-edge preparation.
Lazić Zoran   +3 more
core   +1 more source

Roughness Measurements at Small and Uneven Surfaces of Ceramic Foam Filters

open access: yesSurface and Interface Analysis, EarlyView.
ABSTRACT This study investigated the possibility of roughness characterization of ceramic foam filters using a laser scanning microscope, examining the influence of magnification, measured area, cutoff wavelength (λc), measured roughness parameter, and position within the ceramic foam on the measured roughness data. Firstly, the effect of magnification
Claudia Voigt   +3 more
wiley   +1 more source

Zirconia implant abutments supporting single all-ceramic crowns in anterior and premolar regions: A six-year retrospective study

open access: yesBiomedical Journal, 2019
Background: Clinical studies regarding zirconia implant abutments reported good survival rates in the short-term observation period. The purpose of this study was to assess the six-year clinical performance of zirconia abutments supporting all-ceramic ...
Jo-Yu Chen, Yu-Hwa Pan
doaj   +1 more source

The effect of sterilization and disinfection on the physical-mechanical properties of preformed crowns

open access: yesJournal of Indian Society of Pedodontics and Preventive Dentistry, 2021
Introduction: Different sizes of crowns may be tried on children since there is no universal crown size because of distinctions in tooth morphology from one child to other. During the process of trial and error, the crown gets contaminated which needs to
Shital Kiran Davangere Padmanabh   +1 more
doaj   +1 more source

Die Spacer Thickness Reproduction for Central Incisor Crown Fabrication with Combined Computer-aided Design and 3D Printing Technology: An in vitro Study [PDF]

open access: yes, 2015
Statement of problem The inability to control die spacer thickness has been reported. However, little information is available on the congruency between the computer-aided design parameters for die spacer thickness and the actual printout.
Ahn, Kwang Woo   +4 more
core   +1 more source

Methodology in specimen fabrication for in vitro dental studies : standardization of extracted tooth preparation [PDF]

open access: yes, 2017
Specimen preparation for in vitro study suffers a general lack of methodological homogeneity, as well as a lack of uniformity in the materials selected for fabricating them. This situation prevents comparisons between studies.
Agustín Panadero, Rubén   +4 more
core   +1 more source

Residual Cement Excess of Composite Versus Glass Ionomer Cement in Implant‐Supported Single Crowns After Different Intraoral Exposure Times—A Randomized Controlled Clinical Trial

open access: yesClinical Oral Implants Research, EarlyView.
ABSTRACT Objective To evaluate the frequency and quantity of residual cement after cementation of monolithic zirconia crowns with glass ionomer or resin composite cement on customized ceramic abutments, following different intraoral retention times. The influence of margin location, quadrant and implant region was also assessed.
Maria Weinreuter   +4 more
wiley   +1 more source

Home - About - Disclaimer - Privacy