Results 171 to 180 of about 32,897 (295)

The scale matters: A review on stimuli‐responsive microrobots categorized by scale for biomedical applications

open access: yesResponsive Materials, EarlyView.
We systematically summarize how each scale dictates fundamental choices in design feature, manufacturing technology, driving mechanism, and control strategy, which are inherently governed by scale‐dominated physical principles. Furthermore, the application of scale‐determined operation modes of microrobots across different stages of medical ...
Hang Yin   +3 more
wiley   +1 more source

Sequential Optimization of Multivariate Metal–Organic Framework Based Biocatalysis

open access: yesSmall, EarlyView.
A sequential Latin hypercube sampling–coupled Bayesian optimization (LHS‐BO) workflow integrates multivariate zirconium‐based metal–organic framework based biocomposite (E‐MOF) design with enzyme biocascade reaction optimization. The optimized E‐MOFs stabilize glucose oxidase and horseradish peroxidase in bioactive conformation, exhibiting high ...
Weibin Liang   +4 more
wiley   +1 more source

Engineering Proton Conductive Metal–Organic Glasses Through Secondary Network Formers

open access: yesSmall, EarlyView.
Incorporating secondary network formers enables access to metal–organic glass with tunable structures and properties. This strategy allows systematic control over key metrics, including anhydrous proton conductivities up to 2.6 mS cm−1 at 150°C, a linear increase in glass transition temperature from 11.0°C to 57.4°C, and more than a 200‐fold increase ...
Nattapol Ma   +3 more
wiley   +1 more source

Laboratory Evaluation of the Physicochemical Properties of Novel Pre‐Mixed Putty‐Type Bioceramic Materials

open access: yesAustralian Endodontic Journal, EarlyView.
ABSTRACT This study aimed to compare the physicochemical properties of EndoSequence Root Repair Material (ERRM) Fast and CeraPutty with ProRoot MTA and Biodentine, focusing on setting time, radiopacity, microhardness, and pH. Setting time was measured using a Gilmore‐type indenter applied every 5 min until no indentation was observed (n = 15 per group).
So‐Mang Lee   +3 more
wiley   +1 more source

Chemical Stability and Bond Strength of Endodontic Sealers Exposed to Acidic, Alkaline and Protein‐Rich Environments: An In Vitro Investigation

open access: yesAustralian Endodontic Journal, EarlyView.
ABSTRACT The sealing performance of endodontic sealers may be influenced by environmental factors such as pH and blood‐derived proteins. This in vitro study evaluated the effects of pH variation and protein contamination on calcium ion (Ca2+) release and push‐out bond strength (BS) of a calcium silicate‐based sealer (Bio‐C Sealer) and an epoxy resin ...
Walter Raucci‐Neto   +6 more
wiley   +1 more source

Home - About - Disclaimer - Privacy