Abstract
Over the last decades, packed column supercritical fluid chromatography (pSFC) using carbon dioxide (CO2) as supercritical fluid has gained interest as a complementary separation technique to liquid chromatography (LC). Various commercial solutions for the hyphenation to atmospheric pressure ionization (API) including electrospray (ESI) and atmospheric pressure chemical ionization (APCI) have been described using split-flow or full-flow introduction approaches. This review discusses various aspects of the hyphenation using these two approaches. It also illustrates the difference between LC-MS and SFC-MS. The benefits and challenges of the decoupling of the separation mobile phase from the ionization conditions are also pointed out. The effect of CO2 on ESI performance and the adduct reduction are also discussed. Finally, limitation of current hardware and the limited use of smaller column internal diameters (i.d.) are discussed.

Graphical abstract





Similar content being viewed by others
References
Klesper E, Corwin AH, Turner DA. High pressure gas chromatography above critical temperatures. J Org Chem. 1962;27(2):700–1.
Lesellier E, West C. The many faces of packed column supercritical fluid chromatography – a critical review. J Chromatogr A. 2015;1382:2–46. https://doi.org/10.1016/j.chroma.2014.12.083.
Fjeldsted JC, Lee ML. Capillary supercritical fluid chromatography. Anal Chem. 1984;56(4):619–28. https://doi.org/10.1021/ac00268a004.
Smith RD, Kalinoski HT, Udseth HR. Fundamentals and practice of supercritical fluid chromatography-mass spectrometry. Mass Spectrom Rev. 1987;6(4):445–96. https://doi.org/10.1002/mas.1280060402.
Chollet C, Boutet-Mercey S, Laboureur L, Rincon C, Méjean M, Jouhet J, et al. Supercritical fluid chromatography coupled to mass spectrometry for lipidomics. J Mass Spectrom. 2019;54(10):791–801. https://doi.org/10.1002/jms.4445.
Niessen WMA. Chapter 1. Developments in interface technology for combined liquid chromatography, capillary electrophoresis and supercritical fluid chromatography-mass spectrometry. In: Barceló D, editor. J Chromatogr Lib. Elsevier; 1996. p. 3–70.
Huang E, Henion J, Covey TR. Packed-column supercritical fluid chromatography—mass spectrometry and supercritical fluid chromatography—tandem mass spectrometry with ionization at atmospheric pressure. J Chromatogr A. 1990;511:257–70. https://doi.org/10.1016/S0021-9673(01)93289-3.
Tyrefors LN, Moulder RX, Markides KE. Interface for open tubular column supercritical fluid chromatography/atmospheric pressure chemical ionization mass spectrometry. Anal Chem. 1993;65(20):2835–40. https://doi.org/10.1021/ac00068a021.
Sadoun F, Virelizier H, Arpino PJ. Packed-column supercritical fluid chromatography coupled with electrospray ionization mass spectrometry. J Chromatogr A. 1993;647(2):351–9. https://doi.org/10.1016/0021-9673(93)83415-O.
Tarafder A. Designs and methods for interfacing SFC with MS. J Chromatogr B. 2018;1091:1–13. https://doi.org/10.1016/j.jchromb.2018.05.003.
Guillarme D, Desfontaine V, Heinisch S, Veuthey J-L. What are the current solutions for interfacing supercritical fluid chromatography and mass spectrometry? J Chromatogr B. 2018;1083:160–70. https://doi.org/10.1016/j.jchromb.2018.03.010.
Grand-Guillaume Perrenoud A, Veuthey J-L, Guillarme D. Coupling state-of-the-art supercritical fluid chromatography and mass spectrometry: from hyphenation interface optimization to high-sensitivity analysis of pharmaceutical compounds. J Chromatogr A. 2014;1339:174–84. https://doi.org/10.1016/j.chroma.2014.03.006.
Pinkston JD. Advantages and drawbacks of popular supercritical fluid chromatography/mass interfacing approaches--a user’s perspective. Eur J Mass Spectrom. 2005;11(2):189–97. https://doi.org/10.1255/ejms.731.
Hoke SH, Tomlinson JA, Bolden RD, Morand KL, Pinkston JD, Wehmeyer KR. Increasing bioanalytical throughput using pcSFC-MS/MS: 10 minutes per 96-well plate. Anal Chem. 2001;73(13):3083–8. https://doi.org/10.1021/ac0014820.
Chester TL, Pinkston JD. Pressure-regulating fluid interface and phase behavior considerations in the coupling of packed-column supercritical fluid chromatography with low-pressure detectors. J Chromatogr A. 1998;807(2):265–73. https://doi.org/10.1016/S0021-9673(98)00082-X.
Bolaños BJB, Ventura MCM, Greig MJM. Preserving the chromatographic integrity of high-speed supercritical fluid chromatography separations using time-of-flight mass spectrometry. J Comb Chem. 2003;5(4):451–5.
Hopfgartner G, Bean K, Henion J, Henry R. Ion spray mass spectrometric detection for liquid chromatography: a concentration- or a mass-flow-sensitive device? J Chromatogr A. 1993;647(1):51–61. https://doi.org/10.1016/0021-9673(93)83323-k.
Petruzziello F, Grand-Guillaume Perrenoud A, Thorimbert A, Fogwill M, Rezzi S. Quantitative profiling of endogenous fat-soluble vitamins and carotenoids in human plasma using an improved UHPSFC-ESI-MS interface. Anal Chem. 2017;89(14):7615–22. https://doi.org/10.1021/acs.analchem.7b01476.
Akbal L, Hopfgartner G. Effects of liquid post-column addition in electrospray ionization performance in supercritical fluid chromatography–mass spectrometry. J Chromatogr A. 2017;1517:176–84. https://doi.org/10.1016/j.chroma.2017.08.044.
Nováková L, Rentsch M, Grand-Guillaume Perrenoud A, Nicoli R, Saugy M, Veuthey JL, et al. Ultra high performance supercritical fluid chromatography coupled with tandem mass spectrometry for screening of doping agents. II: analysis of biological samples. Anal Chim Acta. 2015;853:647–59. https://doi.org/10.1016/j.aca.2014.10.007.
Broeckling CD, Ganna A, Layer M, Brown K, Sutton B, Ingelsson E, et al. Enabling efficient and confident annotation of LC-MS metabolomics data through MS1 spectrum and time prediction. Anal Chem. 2016;88(18):9226–34. https://doi.org/10.1021/acs.analchem.6b02479.
Mahieu NG, Patti GJ. Systems-level annotation of a metabolomics data set reduces 25000 features to fewer than 1000 unique metabolites. Anal Chem. 2017;89(19):10397–406. https://doi.org/10.1021/acs.analchem.7b02380.
Bonner R, Stricker T, Hopfgartner G. Adduct ions in electrospray ionization: what are they and why should we care? Proceedings of the 67th ASMS Conference on Mass Spectrometry and Allied Topics, San Diego, CA.
Desfontaine V, Losacco GL, Gagnebin Y, Pezzatti J, Farrell WP, González-Ruiz V, et al. Applicability of supercritical fluid chromatography – mass spectrometry to metabolomics. I – optimization of separation conditions for the simultaneous analysis of hydrophilic and lipophilic substances. J Chromatogr A. 2018;1562:96–107. https://doi.org/10.1016/j.chroma.2018.05.055.
Matuszewski BK, Constanzer ML, Chavez-Eng CM. Matrix effect in quantitative LC/MS/MS analyses of biological fluids: a method for determination of finasteride in human plasma at picogram per milliliter concentrations. Anal Chem. 1998;70(5):882–9. https://doi.org/10.1021/ac971078+.
Kebarle P, Tang L. From ions in solution to ions in the gas phase - the mechanism of electrospray mass spectrometry. Anal Chem. 1993;65(22):972A–86A. https://doi.org/10.1021/ac00070a001.
Wolrab D, Frühauf P, Gerner C. Direct coupling of supercritical fluid chromatography with tandem mass spectrometry for the analysis of amino acids and related compounds: comparing electrospray ionization and atmospheric pressure chemical ionization. Anal Chim Acta. 2017;981:106–15. https://doi.org/10.1016/j.aca.2017.05.005.
Haglind A, Hedeland M, Arvidsson T, Pettersson CE. Major signal suppression from metal ion clusters in SFC/ESI-MS - cause and effects. J Chromatogr B. 2018;1084:96–105. https://doi.org/10.1016/j.jchromb.2018.03.024.
Desfontaine V, Capetti F, Nicoli R, Kuuranne T, Veuthey J-L, Guillarme D. Systematic evaluation of matrix effects in supercritical fluid chromatography versus liquid chromatography coupled to mass spectrometry for biological samples. J Chromatogr B. 2018;1079:51–61. https://doi.org/10.1016/j.jchromb.2018.01.037.
Riddell N, van Bavel B, Ericson Jogsten I, McCrindle R, McAlees A, Chittim B. Coupling supercritical fluid chromatography to positive ion atmospheric pressure ionization mass spectrometry: ionization optimization of halogenated environmental contaminants. Intl J Mass Spectrom. 2017;421:156–63. https://doi.org/10.1016/j.ijms.2017.07.005.
West C, Melin J, Ansouri H, Mengue MM. Unravelling the effects of mobile phase additives in supercritical fluid chromatography. Part I: polarity and acidity of the mobile phase. J Chromatogr A. 2017;1492:136–43. https://doi.org/10.1016/j.chroma.2017.02.066.
Desfontaine V, Nováková L, Ponzetto F, Nicoli R, Saugy M, Veuthey J-L, et al. Liquid chromatography and supercritical fluid chromatography as alternative techniques to gas chromatography for the rapid screening of anabolic agents in urine. J Chromatogr A. 2016;1451:145–55. https://doi.org/10.1016/j.chroma.2016.05.004.
Desfontaine V, Tarafder A, Hill J, Fairchild J, Grand-Guillaume Perrenoud A, Veuthey JL, et al. A systematic investigation of sample diluents in modern supercritical fluid chromatography. J Chromatogr A. 2017;1511:122–31. https://doi.org/10.1016/j.chroma.2017.06.075.
Glenne E, Samuelsson J, Leek H, Forssen P, Klarqvist M, Fornstedt T. Systematic investigations of peak distortions due to additives in supercritical fluid chromatography. J Chromatogr A. 2020;461048. https://doi.org/10.1016/j.chroma.2020.461048.
Fujito Y, Hayakawa Y, Izumi Y, Bamba T. Importance of optimizing chromatographic conditions and mass spectrometric parameters for supercritical fluid chromatography/mass spectrometry. J Chromatogr A. 2017;1508:138–47. https://doi.org/10.1016/j.chroma.2017.05.071.
Svan A, Hedeland M, Arvidsson T, Pettersson CE. The differences in matrix effect between supercritical fluid chromatography and reversed phase liquid chromatography coupled to ESI/MS. Anal Chim Acta. 2018;1000:163–71. https://doi.org/10.1016/j.aca.2017.10.014.
Laboureur L, Bonneau N, Champy P, Brunelle A, Touboul D. Structural characterisation of acetogenins from Annona muricata by supercritical fluid chromatography coupled to high-resolution tandem mass spectrometry. Phytochem Anal. 2017;28(6):512–20. https://doi.org/10.1002/pca.2700.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflicts of interest.
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Akbal, L., Hopfgartner, G. Hyphenation of packed column supercritical fluid chromatography with mass spectrometry: where are we and what are the remaining challenges?. Anal Bioanal Chem 412, 6667–6677 (2020). https://doi.org/10.1007/s00216-020-02715-4
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00216-020-02715-4