Introduction

Most countries in the world are presenting growth in the proportion of older persons in their population. According to the latest United Nations population estimates and projections, one in six people in the world will be over age 65 (16.4%) by 2050, up from one in 11 in 2019 (9.7%) [1]. And the older one gets, the higher the risk of edentulism. Although the rates of edentulism have been slowly falling in some countries [2], the prevalence of edentulism is still very high among the elderly, as these are at greater risk for poor oral health and tooth loss as compared with those < 65 years of age, with dental caries and periodontal disease being the main causes of tooth loss [3]. Recent estimated on the global prevalence of edentulism among individuals aged 45 or older is 22% [4].

With the edentulism comes the resorption of the alveolar socket and volume decrease of the jaw bone [5, 6], a process that continues even after patients begin to wear removable complete dentures [7], all of which can significantly alter the shape of the jaws [8].

The lack of enough bone volume for the placement of traditional, normal-diameter implants in the edentulous jaws leaves some options for oral prosthetic rehabilitation. One would be the removable complete denture, that lies directly on the gingiva/mucosa of the edentulous alveolar ridge, which is a cheap, straightforward process to manufacture, and easy to maintain by the patient, but which can bring discomfort, become loose, and the patient may have problems to adapt to it [9]. The edentulous patient’s chewing capacity and bite force remain both impaired, as this type of prosthesis may become unstable or lack retention due to poor availability of residual bone [10]. Moreover, removable complete dentures can give rise to lesions of the oral mucosa [11].

Another option would be to graft the alveolar ridge with additional bone to create sufficient bone volume for the placement of implants of conventional diameter [12, 13]. However, these interventions are invasive and subject to intraoperative and postoperative complications, such as exposure of the grafted material, infection, neurosensorial disturbances, hemorrhage, pain, among others [14], besides being costly for the patient.

The use of mini-implants would be a third alternative. Mini-implants consist of a dental implant that is fabricated with a reduced diameter, up to 3.0 mm [15], while narrow or conventional diameter implants have a diameter greater than 3.0 mm. As advantages, the placement of mini-implants is simpler and less invasive, and the entire procedure is also less time-consuming in comparison to the installation of implants of wider diameter [16]. Moreover, due to their narrow diameter, mini-implants can be placed in jaw sites with less bone volume and less thickness, minimizing the need for bone grafting procedures in atrophic ridges. Furthermore, the cost of mini-implants is significantly less than implants with wider diameters [17]. In relation to removable complete denture, patients rehabilitated with overdentures retained by mini-implants are more satisfied, due to increased retention and stability of the prosthesis, increased mastication efficiency, improved comfort, and security in social life [10, 18, 19].

However, there are potential problems and complications associated with the use of mini-implants to support overdentures. These implants present a higher risk of fracture, due to its narrow diameter [20], as well as due a less-than-ideal balanced distribution of the forces of mastication in this type of prosthesis, leading to a high stress concentration on implants that are nearest to the place of loading [21]. Moreover, narrow-diameter implants may be associated with greater marginal bone loss in comparison to standard-diameter implants [22]. In addition, elderly individuals, who are more prevalently rehabilitated with implant-supported overdentures, usually present an increase in cognitive and physical disabilities, which can lead to poor oral hygiene [23]. Poor oral hygiene is suggested to be a risk for peri-implant health, leading to chronic inflammation and ultimately to loss of implants [24]. Other systematic reviews separately assessed the clinical outcomes of mini-implant-retained overdentures in the maxilla and in the mandible. These reviews reported a lower survival rate for mini-implants in the maxillary cases (77.1%, mean follow-up of 1.79 years) [25] than the mandibular ones (95.6%, mean follow-up time of 28.2 months) [26]. However, the authors of these reviews reported plain survival rates, without properly looking into the time factor. Moreover, the radiographic outcomes were not assessed.

The purpose of the present study was to assess the clinical and radiographic outcomes of maxillary and mandibular overdentures and their retaining dental mini-implants, based on a systematic review of the literature.

Materials and methods

This single-arm systematic review followed the PRISMA Statement guidelines [27]. The review was registered in PROSPERO (CRD42023487478).

Research question

The focused question was: What is the failure rate, the prevalence of technical complications, and the estimated mean marginal bone loss of dental mini-implants and mini-implant-retained overdentures used for the rehabilitation of patients with edentulous jaws?

Search strategies

An electronic search without time restrictions was firstly undertaken in August 2022, last updated in October 2023, in the following databases: PubMed/Medline, Web of Science, and Scopus. The following terms were used in the search strategies:

(“mini-implant” OR “mini dental implant” OR “small diameter dental implant” OR “small diameter implant” OR “small dental implant” OR “narrow diameter dental implant” OR “narrow diameter implant” OR “narrow dental implant” OR “provisional implant” OR “temporary implant”) AND (overdenture OR “coping prosthesis” OR “overlay prosthesis” OR “overlay denture” OR “full denture” OR denture OR “complete denture”).

A manual search of the following journals was performed: Clinical Implant Dentistry and Related Research, Clinical Oral Implants Research, European Journal of Oral Implantology, Implant Dentistry, International Journal of Implant Dentistry, International Journal of Oral and Maxillofacial Implants, International Journal of Oral Implantology, International Journal of Prosthodontics, Journal of Clinical Periodontology, Journal of Oral Implantology, Journal of Periodontology, Journal of Prosthetic Dentistry, Journal of Prosthodontics, Journal of Prosthodontic Research. The reference list of the identified studies and the relevant reviews on the subject were also checked for possible additional studies.

Inclusion and exclusion criteria

Eligibility criteria included clinical human studies, either randomized or not, interventional or observational, reporting case series of patients rehabilitated with mini-implant-retained overdenture. Case reports were also considered, provided that follow-up information was reported. Implants of titanium (c.p.Ti) or its alloys were included.

The following cases were excluded: (1) patients receiving overdentures retained/supported simultaneously by teeth and implants; (2) case series report from which no individual patient data could be extracted; (3) partial overdentures; (4) cases with no prosthetic follow-up– cases with follow-up time only between the implant placement and prosthesis installation were not considered as the main aim of the present review was to evaluate the prosthetic phase; (5) studies suspected to present duplicated cases, usually originating from clinical series from the same service or university, but in different articles/publications; (6) case series studies with shorter follow-up time will not be considered, provided that a longer follow-up publication will be available; (7) case series of patients treated for head and neck cancers and/or ablative surgery of the jaws, as these cases are already expected to present an increased failure rate of implants [28], and also due to the fact that the clinical outcomes for these cases could strongly deviate from patients not in the same situation, due to, for example, osteoradionecrosis, constant ulceration of the oral mucosa, xerostomia, among others [29, 30].

Study selection

The titles and abstracts of all reports identified through the electronic searches were read independently by the authors. For studies appearing to meet the inclusion criteria, or for which there were insufficient data in the title and abstract to make a clear decision, the full report was obtained. Disagreements were solved by discussion between the authors.

RefWorks Reference Management Software (Ex Libris, Jerusalem, Israel) was used in order to detect duplicate references in different electronic databases.

Quality assessment

Quality assessment was executed according to the Quality Assessment Tool of the National Institutes of Health [31]. The NIH quality assessment tool calculates the study quality on the basis of nine criteria. The ratings on the different items were used by the reviewers to assess the risk of bias in the study due to flaws in study design or implementation. The studies were classified as “good,” “fair,” or “poor” quality. In general terms, a “good” study has the least risk of bias, and results are considered to be valid. A “fair” study is susceptible to some bias deemed not sufficient to invalidate its results. The fair quality category is likely to be broad, so studies with this rating will vary in their strengths and weaknesses. A “poor” rating indicates significant risk of bias. Studies of “good” quality were judged to have at least 7 points.

Quality assessment of the included case report publications was carried out according to the 13-item CARE guidelines [32] were used for the quality assessment of the case report articles. A score of 1 was given for each item outlined in the CARE guidelines, with a maximum score of 30 for a case report. A score of 30 represents the highest quality, and two-thirds or more of the points are considered high quality.

The reviewers went together through all the items of the NIH quality assessment tool for five case-series studies as an initial calibration, after which the quality assessment was carried out independently by the reviewers. Any disagreement was resolved by discussion between the authors. All the reviewers performed together the quality assessment of the case report publications, due to the small number of included publications of this type.

Definitions

A mini-implant was defined as a dental implant that is fabricated with a reduced diameter (up to 3.0 mm) with the same biocompatible material as compared with standard dental implants [15].

An implant was considered a failure if presenting signs and symptoms that led to implant removal, i.e., a lost implant. Implant failure could be either early (the inadequacy of the host to establish or promote osseointegration in the early stages of healing) or late (the failure of either the established osseointegration or function of dental implants) [33]. Fracture of an implant was also considered as a failure [20].

A mini-implant-retained overdenture was defined any removable dental prosthesis that covers and rests on one or more dental mini-implants.

An overdenture was considered a failure in the following situations: (1) loss of the supporting implant(s); (2) new implants were placed in the jaw in order to support a fixed full-arch prosthesis; (3) change of attachment system; and (4) complete transverse fracture of the overdenture.

MBL was defined as loss, in an apical direction, of alveolar bone marginally adjacent to the dental implant, in relation to the marginal bone level initially detected after the implant was surgically placed [34]. Studies using the long-cone parallel technique for periapical radiographs were considered.

Data extraction

From the studies included in the final analysis, the following data was extracted: number of patients, patients’ age and sex, implant healing period, number of supporting implants per overdenture, implant surface modification, number of attachments per overdenture, type of attachment used, use of a metal structure/cast mesh for reinforcement of the prosthesis, occurrence of implant and/or prosthesis failure, time from implant/prosthesis installation to failure, occurrence of technical complications, follow-up time.

Information on the following technical complications was collected, when available: fracture of acrylic teeth, fracture of prosthesis acrylic base, complete transverse fracture of the overdenture, attachment male or female part loose, attachment female part fracture or worn out, replacement of attachment components, overdenture relining, implant fracture.

Contact with authors for possible missing data was performed.

Analyses

The mean, standard deviation (SD), and percentage were calculated for the aforementioned variables, whenever suitable. The test performed were the following: Kolmogorov–Smirnov (to evaluate the normal distribution), Levene’s test (to evaluate homoscedasticity), Student’s t-test or Mann-Whitney (for two independent groups, continuous variables), Pearson’s chi-squared or Fisher’s exact test (for categorical variables). The log-rank (Mantel-Cox) test was used to compare the survival distributions of implants between the maxilla and the mandible. The interval survival rate (ISR) of implants and prosthesis was calculated using the information for the period of failure retrieved from the included studies, and the cumulative survival rate (CSR) was calculated over the maximal period of follow-up reported, in a life-table survival analysis. The degree of statistical significance was considered p < 0.05. These data were statistically analyzed using the SPSS version 28 software (SPSS Inc., Chicago, IL, USA).

A meta-analysis applying the DerSimonian-Laird random-effects method (DerSimonian and Laird, 1986) was performed to calculate the estimated MBL under different follow-up times. The I2 statistic was used to express the percentage of the total variation across studies due to heterogeneity, with 25% corresponding to low heterogeneity, 50% to moderate and 75% to high. A meta-regression assessing the relationship between mean MBL and follow-up was performed. The data were analyzed using the statistical software OpenMeta[Analyst] [35].

Results

Literature search

The study selection process is summarized in Fig. 1. The search strategy in the databases resulted in 2,466 papers (432 in PubMed/Medline, 110 in Web of Science, 1,924 in Scopus). A total of 386 articles were cited in more than one database (duplicates). The reviewers independently screened the abstracts for those articles related to the aim of the review, leading to the exclusion of 1,927 articles as the studies were not related to the subject. Of the resulted 153 studies, 114 were excluded due to one or more reasons for exclusion, according to the exclusion criteria. Hand-searching of journals and of the reference lists of selected studies yielded 2 additional papers, not eligible though. Thus, 39 studies were included in the review [10, 18, 19, 36,37,38,39,40,41,42,43,44,45,46,47,48,49,50,51,52,53,54,55,56,57,58,59,60,61,62,63,64,65,66,67,68,69,70,71].

Fig. 1
figure 1

Study screening process

Description of the studies

Detailed data on every publication is presented in Table S1, in the Supplementary Material. Table 1 presents the summarized global data of the included studies, also separately between overdentures installed in different jaws.

The 39 included publications reported 3,787 mini-implants supporting 1,026 overdentures (109 in maxillae, 896 in mandibles) in 1,005 patients. Twenty-one patients had mini-implant-retained overdenture in both the maxilla and mandible. The 1,005 patients consisted of 396 men and 496 women, with no information on sex for 114 patients. The mean follow-up was 28.1 ± 19.8 months (min-max 0.3–84.0). A total of 202 mini-implants failed, after a mean of 9.4 ± 11.8 months (min-max 0.3–60.0). Failure at the patient level was 133/1,005 (13.2%). Seventy-six out of 1,026 prostheses were considered as failures, the main reason (n = 69; 90.8%) being transversal fracture of the overdenture.

Most of the implants in the mandible were submitted to immediate loading, while in the maxilla the delayed loading protocol was more commonly applied. O-ring-ball was the most commonly used attachment system, followed by Equator, Locator, and bar-clip system. A high rate of transversal fracture of the prosthesis and wear of the attachment parts was observed. Relining of the prosthesis base was a common needed maintenance process.

Table 1 Summarized data of the included studies

Analyses

A total of 202 mini-implants were considered as failure, with a clear concentration of failures in the first year of follow-up (Table 2). The 7-year CSR was 91.4%. The CSR was lower at 5 years for mini-implants placed in the maxilla (87.1%, Table 3) in comparison to mini-implants placed in the mandible (92.3%, Table 4), and the difference in survival was statistically significant (p < 0.001; Log-rank test).

The survival of implants submitted to early/delayed loading was lower than implants immediately loaded (p < 0.001; Log-rank test), which was true even when only mandibular implants were considered (p = 0.005; Log-rank test). This, however, was the opposite when only maxillary implants were considered (p < 0.001; Log-rank test).

When only mandibular overdentures were considered, there was a higher implant failure rate (p < 0.001; Log-rank test) among 2-mini-implant retained overdenture (43/548, 92.2% survival) in comparison to 4-mini-implant retained overdenture (90/2384, 96.2% survival).

Unfortunately, information about the time point of failure for the overdentures was available for only 19 of the 76 failures. Therefore, a life-table analysis for the prostheses was not carried out.

Table 2 Life-table survival analysis showing the cumulative survival rate of mini-implants to support overdentures
Table 3 Life-table survival analysis showing the cumulative survival rate of mini-implants to support overdentures in the maxilla
Table 4 Life-table survival analysis showing the cumulative survival rate of mini-implants to support overdentures in the mandible

Table 5 shows the results of the meta-analyses for the outcome MBL under different follow-ups. The estimated mean MBL gradually increased from 0.518 mm (≤ 6 months) to 1.260 mm (58.8–90 months).

Table 5 DerSimonian-Laird random-effects model analysis for MBL under different follow-ups

A meta-regression considering the effect of follow-up on the mean MBL (Fig. 2) resulted in the following first-degree equation:

y = 0.528 + 0.011x, where:

Intercept = 0.528 (0.362, 0.694), standard error 0.085, p < 0.001.

Follow-up = 0.011 (0.006, 0.017), standard error 0.003, p < 0.001.

There was an estimated increase of 0.011 mm in MBL for every additional month of follow-up, with statistical significance.

Fig. 2
figure 2

Scatter plot for the meta-regression with the association between follow-up (in months) and mean marginal bone loss (MBL). Positive values mean bone loss, while the negative values mean bone gain. Every circle represents a study or a different follow-up point in a same study, and the size of the circle represents the weight of the study in the analysis. The blue line represents the fitted line plot

Quality assessment

All included studies were classified as “good” according to the quality assessment tool (see Tables S2 and S3, Supplementary Material). In most cases the main issues in the publications were related to not well-described statistical methods, and to the inclusion of non-consecutive patients in the studies. These issues were not a problem though, since there was information about follow-up as well as the main outcome, namely, mini-implant failure.

Discussion

The purpose of the present review was to assess the clinical outcomes of overdentures retained by dental mini-implants. The results showed that mini-implants used to retain/support overdentures present a high CSR over 7 years, namely 91.4%.

Most of the implant failures happened during the first year. Moreover, a high rate of primary failure (up to prosthetic loading) was observed among the implants that were not submitted to immediate loading. A considerable percentage of implants fail in the early period after implant installation [72], regardless of the follow-up time [73]. One has to consider that a reduced implant diameter means a reduction in the bone-implant contact surface area, which could compromise the osseointegration process [74], or not be enough to withstand loading forces [75]. Furthermore, mini-implants usually are the option for rehabilitation in sites with poorer bone quality and lack of bone volume, which may not only directly influence the implant initial stability values [76], but also statistically affect implant survival rates in a negative manner [77]. All this may have a substantial impact on prosthetic rehabilitation plan [78], since the rehabilitation with mini-implants may be already seen as the last resource for an implant-retained prosthesis, due to the scarcity of available bone, without the need of more invasive approaches such as bone grafting procedures.

Immediate loading of the mini-implants was common for overdentures in the mandible, but very uncommon for overdentures in the maxilla. This may be related to the maxillary bone being more trabecular and softer than the mandibular bone, which is denser (Lekholm and Zarb, 1985), which in turn is generally perceived as resulting in lower primary stability, greater micromotion, and consequently a greater risk of maxillary implants to osseointegrate when submitted to immediate prosthetic loading [77, 79,80,81]. In fact, it was observed in the present results that the survival of immediately loaded implants was lower than implants submitted to early/delayed loading, when only the maxilla was considered. Due to the reduced diameter of mini-implants, it may be prudent to undersize the preparation of the implant bone sites, as well as to do not immediately load the implants when the clinically perceived primary stability is lower than an insertion torque value of 10 Ncm and an resonance frequency analysis of 60 [82]. According to a recent review, however, implants supporting fixed prostheses (not overdentures) in the maxilla subjected to immediate loading present high survival rates [83].

When only mandibular overdentures were considered, there was lower implant survival for 2-mini-implant-retained in comparison to 4-mini-implant-retained mandibular overdenture. It has been suggested that 2-mini-implant-retained mandibular overdenture could be used for cost-effectiveness clinical situations [41], although a 4-mini-implant-retained overdenture is associated with higher patient satisfaction [43]. Moreover, a FEA study observed that an overdenture retained by 4 implants is steadier than one retained by 2 implants when functioning with the anterior teeth. In the same study it was also observed that under the simulated action of cutting food with the anterior teeth, the maximum stress value in the abutments with the 2-implant model was three-fold than with the 4-implant model, suggesting that higher risk of damage to the abutments in 2-implant overdentures [84]. Due to the aforementioned reasons, the use of 4 mini-implants to retain mandibular overdentures is recommended instead of only 2 mini-implants.

The attachment system most commonly used was of the O-ring-ball system. This can be associated with narrow diameter of the mini-implants, which limits the space for wider, more elaborated, attachment systems. And also, to the fact that mini-implants are usually commercialized as one-piece implants.

There was a high rate of transversal fracture of the prosthesis, which usually happens due to the thinning and weakening of the acrylic resin bases in the area of the prosthesis that harbors the matrix part of the attachment systems [85]. This type of fracture is commonly reported by studies in which existing complete dentures are transformed into implant-retained overdentures [86]. Metal frameworks could minimize the occurrence of overdenture fractures [57].

Considering the relatively high rate of some technical complications, it can be said that mini-implant-retained overdentures may require frequent maintenance follow-ups to address the complications, which is usual with implant-retained overdentures [87, 88]. It has been suggested that substituting the direct chairside attachment matrix pick-up technique with an indirect laboratory procedure may reduce the number of complication events and consequently of maintenance appointments [89].

A high rate of prosthesis relining was observed, something that is expected in cases of immediate loading (the majority of the cases observed in the review), probably due to progressive subsiding of the postoperative swelling [88]. This must be weighed with the suggestion that immediate loading may result in lower postoperative symptoms and lower levels of pain and functional discomfort during the 6-week healing period [16].

Regarding MBL, a finite element analysis (FEA) study showed that the stresses in cortical bone decrease in inverse proportion to the increase in implant diameter with both vertical and lateral load [90]. More specific to mini-implants, stress and strain occurring are mainly localized at the cortical bone around the bone-implant interface [91], with higher bone loading in comparison to standard diameter implants, which could increase the risk of MBL around mini-implants [92]. However, the present results seem to indicate that MBL around mini-implants retaining overdentures present acceptable results in relation to wider diameter implants [93].

Limitations of the present review include the fact that there was a considerable number of confounding factors. There was no information about how many implants were inserted and failed in several different conditions for most (if not all) of the studies. Studies reported the presence of diabetics among the patients, as well as smokers, bruxers, and patients taking selective serotonin reuptake inhibitors, proton-pump inhibitors, or bisphosphonates, which are medications commonly prescribed for the elderly. All these factors could have had a considerable impact on implant failure rates [94,95,96,97,98,99]. Furthermore, the retrospective nature of many studies results in flaws manifested by the gaps in information. In addition, several studies presented small cohort sizes and short follow-ups. The global number of mini-implant supported overdentures installed in the maxilla reported in the literature is still small, so more studies are needed in order to draw more robust conclusions.

Based on present results, it can be recommended the use of 4 mini-implants in the mandible for retaining overdenture prostheses, as there is a better implant survival prognosis for this option in comparison to when only 2 mini-implants are used. Mini-implants should not be immediately loaded when the clinically perceived primary stability is low, something that can be quantitatively verified by the values of insertion torque and resonance frequency analysis. Due to the high rate of prosthesis transversal fracture, it is recommended the manufacture of overdentures with metal frameworks, which could minimize the occurrence of this complication. It is recommended that dentists maintain a regular and close follow-up of patients rehabilitated with this mini-implant supported overdentures, due to the expected high prevalence of technical complications. Moreover, substituting the direct chairside attachment matrix pick-up technique with an indirect laboratory procedure may reduce the number of complication events and consequently of maintenance appointments.

Conclusions

Although presenting a high 7-year CSR and acceptable MBL, mini-implant-retained overdentures may require frequent maintenance follow-ups, due to the high rate of technical complications.