High-performance in-vacuum optical system for quantum optics experiments in a Penning-trap
EPJ Quantum Technology volume 12, Article number: 58 (2025)
Abstract
Accurate measurements with implications in many branches of physics have been accessed using conventional techniques in Penning traps within a temperature regime where each eigenmotion of a charged particle is still a classical harmonic oscillator. Cooling the particle directly or indirectly with lasers allows reaching the quantum regime of each oscillator, controlling subtle effects in the precision frontier by detecting photons instead of electric currents. In this paper, we present a new in-vacuum optical system designed to detect 397-nm fluorescence photons from individual calcium ions and Coulomb crystals in a 7-T Penning trap. Based on the outcome of computer simulations, our design shows diffraction-limited performance. The system has been characterized using a single laser-cooled ion as a point-like source, reaching a final resolution of 3.69(3) μm and 2.75(3) μm for the trap’s axial and radial directions, respectively, after correcting aberrations.
1 Introduction
Quantum optics experiments with cooled trapped ions rely on optical imaging systems for the detection of the fluorescence photons emitted by the ions [1]. Typically, an internal electric-dipole transition of the ion with a lifetime in the order of nanoseconds is addressed by laser light and a fraction of the emitted photons is collected by the optical system and focused on photon detectors such as electron-multiplying charge-coupled devices (EMCCDs) and photomultiplier tubes (PMTs) [2, 3]. A high numerical aperture (NA), which allows collecting a few percent of the emitted fluorescence, is essential to achieve a fast detection (in the order of milliseconds) at the single particle level in experiments involving non-destructive internal state discrimination [4].
Customized optical systems consisting of multiple lenses to minimize aberrations [5] are popular in cold-atom experiments and radiofrequency/Paul traps. The typical limited size of these setups allows placing the objective outside vacuum so that a proper alignment can be performed to achieve diffraction-limited performance. Comparatively, Penning traps based on superconducting magnets are subject to spatial constrains due to their large volume and the limited size of the bore. In the framework of Penning-trap experiments, fluorescence detection at the single ion level has only been demonstrated in experiments devoted to quantum simulation [6], quantum computation [7, 8], or new schemes to measure fundamental constants [9]. Opposite to these Penning-trap experiments, the optical system discussed in this work has been implemented in vacuum in a beamline-like setup [10] which includes external ion sources to create any species of interest.
Our main motivation is to perform Penning-trap motional-frequency spectroscopy in the quantum regime [11], to improve the detection based on monitoring the electric current a single charged particle induces on the trap electrodes [12]. Although this technique and its variants have yielded remarkable results for atomic mass determination in various fields [13–19], photon detection could still be advantageous due to its universality in terms of mass-to-charge ratio and the ultra-low motional energies required [20]. This method allows access to an in-principle unlimited range of elements and provides sympathetic cooling to very low temperature of the ion of interest. This contributes to a better monitoring of the systematic effects arising from trap imperfections if the two-ion crystal (sensor plus target ion) is in the ground state. Furthermore, besides mass spectroscopy, such a two-ion platform can be used to test quantum logic spectroscopy in an environment free of micromotion, preventing one of the main systematic uncertainties present when this scheme is implemented in a Paul trap [21]. The method has been recently demonstrated in our group for a single ion cooled to the Doppler limit using the high-resolution optical system described in this paper [22]. The eigenmotions of the ion were individually probed by an external electric field and its motional amplitude was measured directly from the photon distribution determined with the EMCCD or from the photon counting with a PMT. The higher spatial resolution of the optical system leads to reduced systematic uncertainties.
In this paper, we first present the design guidelines of the new optical system developed for the Penning-trap experiment at the University of Granada. We then discuss the results of the simulations, which indicate diffraction-limited performance. We also present the characterization of the system in terms of resolution using square impulse targets. Finally, we show the analysis of images of a single laser-cooled ion at the Doppler limit (point-like source) using wave-aberration retrieval techniques to evaluate the performance of the system once it was installed in vacuum.
2 Design and simulations
Figure 1 shows the conceptual design of the optical system and its arrangement in the experimental setup (a detailed description of the Penning-trap beamline can be found elsewhere [10, 23]). Most of it (about 1.2 m) operates under UHV conditions, being rigidly anchored to the Penning-trap tower. It consists of an objective (O) that provides 5× magnification and a series of lenses (R1-R4) that relay the image without magnification. Field lenses (FL1-FL4) consisting of pairs of plano-convex lenses centered on the image plane are used to avoid vignetting [24]. A final factor of 15× is achieved by adding a single lens outside vacuum. This value is high enough so that two ions are imaged a few pixels apart when projected onto the EMCCD sensor (Andor iXon Ultra 888, \({13\times 13}\) μm). The relays are doublets of plano-concave and bi-convex commercial lenses in which the relative distance was optimized to achieve diffraction-limited performance. All the lenses are commercial models made from N-BK7 or Fused Silica and have anti-reflective coating for \({\lambda =397}\text{ nm}\).
The optical system in the Penning-trap beamline. Center: rendered three-dimensional drawing including the 7-T superconducting magnet and the rest of the setup. Top: cross-section sketch (not-to-scale). Bottom: rendered two-dimensional cut where several distinctive elements are zoomed in. O: objective; M: mirror; FL: field lens; R: relay; VP: viewport. CL stands for a cylindrical lens not included in the simulations, but useful to correct astigmatism aberrations (see Sect. 4)
The objective is based on an aspheric lens. Other alternatives based on diffraction-limited four-lens objectives [5, 25, 26] were discarded because of the little space available in vacuum. It is comprised of 1/2”-diameter lenses, whose specifications are detailed in Appendix A. The relative distances between the different elements were optimized using Zemax (Zemax OpticStudio® 2020), for which the wave aberration, defined as the optical path difference between the ideal paraxial wavefront and the real one, was used as the figure of merit to minimize. First, the focal point of the asphere was determined for \({\lambda =397}\text{ nm}\), resulting in a working distance of 21.963 mm. Then, the relative distance in the doublet consisting of the bi-convex and the plano-concave lenses was optimized. The gap between the asphere and the doublet was chosen arbitrarily (5 mm in this case), and the field lens FL1 was likewise placed at a certain distance from the image plane. The effect the latter has on the image formation is minimal, and it only acts as a defocus. The optimization routine was run again for the two previously varied distances. Near on-axis diffraction-limited performance was achieved in all the cases, which was observed in the modulation transfer function (MTF) and wave-aberration plots (see Appendix B for a short summary of concepts imaging system analysis).
The sequential procedure for optimizing the relay lenses (R1–R4) is the same as for the objective (specifications in Appendix A). The final part of the optical system, called R4 in Fig. 1, consists of half of a one-inch relay plus a single lens with a focal length of \({f'\approx 750}\text{ mm}\). Although the latter is a simple plano-convex lens, it does not introduce further significant aberrations due to its small NA.
The optical mounts are custom made and the distance between the elements is maintained using hollow tubes, with very-fine threads to assure a good alignment. All the pieces are perforated to pump the inner volume of the tubes. The optimal lens spacings found in the simulations are physically defined by lens separators with the shape of the corresponding spherical lens so that the contact is made on the full contour of the surface for better alignment.
Figure 2 shows some of the simulation results for the entire optical system. The performance of the optical system is computed based on the wave aberration (right side of Fig. 2). This function can be calculated analytically if one knows the shape of the lenses, listed in Appendix A. Although the system is diffraction-limited for on-axis performance, it cannot be moved once installed under UHV, so it is important to know its off-axis performance. For this purpose, the impulse was placed at different field distances from the optical axis on the object plane. The MTF and the root mean square (RMS) spot radius (inset) show that a position deviation of 200 μm, corresponding to a wave aberration of 1.5 λ, is the maximum affordable deviation to resolve around 10 μm. In the case of the modulation, a value of 0.2 corresponds to the Rayleigh criterion for two-point resolution (the first intensity minimum of each point lays on the maximum of the other).
Simulation of the optical system. Left: MTF’s tangential component for an object placed at different field positions and RMS spot radius (inset). The axis of abscissa represents the spatial frequency in the object plane. Top right: colour map representation of the on-axis wave aberration in wavelength units. The circle represents the exit pupil of the optical system. Bottom right: tangential (left) and sagittal (right) cross sections of the wave aberration for an object placed at different field positions. The field coordinate is given in units of the exit pupil, defined as the image of the aperture stop formed by the part of the system which follows it
3 Out-of-vacuum performance analysis
The response of the system to square-wave impulses was investigated outside vacuum using a 1951 USAF test target (Thorlabs Inc. R1DS1P). The object, placed in the objective’s focal plane, consisted of two sets of three parallel bars, oriented in two perpendicular directions and separated by different distances. The optical system was fixed to an optical table, and the resolution target was mounted on a three-axis stage so that the region of interest could be placed at the focal point. The camera used was a scientific complementary metal-oxide-semiconductor (sCMOS) image sensor (Andor Zyla 4.2). The target was illuminated with 397-nm light, and measurements were performed on groups 4, 5, 6, and 7 (line separation from 31 μm to 4.2 μm). The magnification obtained was \({16.8(4)\times}\). By measuring the maximum and minimum intensities on the sCMOS sensor, \(I_{\mathrm{max}}\) and \(I_{\mathrm{min}}\), it was possible to determine the contrast transfer function (CTF) as
The CTF is the analogous function to the MTF but for square impulses.
If the set of square impulses is chosen as a complete and orthogonal basis, the CTF can be calculated as the inner product of the object and the image, both normalized to the total intensity. Another way of evaluating the performance is to work on the Fourier basis so that the convolution theorem can be applied,
where \(I_{g}\) and \(I_{i}\) are the intensities in the object and image planes, respectively.
Figure 3 shows the performance of the optical system as a function of the spatial frequency of the object. The square-impulse analysis is shown on the left side. Similar results are obtained using the CTF and the MTF, being the performance close to the diffraction limit down to at least 5 μm of line separation. A deeper insight into higher frequencies was reached by employing the method using the deconvolution theorem to measure the system’s MTF. In the analysis shown on the right side of Fig. 3, the fundamental frequency and the third harmonic were used, obtaining reliable results. From the relationship between the modulation and the Rayleigh criterion, the optical system is capable of resolving two points separated by only 1.5 μm. Using Eq. (2) for higher harmonics resulted in large uncertainties. A description of the measurement and analysis procedures can be found in Appendix C.
Frequency analysis of the measurements based on the 1951 USAF resolution target. The displayed data are the average of the performance for each two perpendicular bar sets of this test target. Left: CTF measured directly and from the image-object product. Right: MTF calculated using the convolution theorem. The lower grey dashed line includes the sensor (6.5 μm × 6.5 μm) frequency transmission
4 In-vacuum performance analysis
A single trapped ion cooled to the Doppler limit is a perfect target to determine the point spread function (PSF) of the optical system. In the case of the Penning trap, the axial frequency was \({\omega _{z}=2\pi \times 333}\text{ kHz}\) (see Ref. [22] for details about the technique), which implies a motional amplitude \({z_{\mathrm{max}}\approx 300}\text{ nm}\) for 40Ca+ at 1 mK in the Doppler limit (see Ref. [10] for an upper estimation in our setup). Since \({z_{\mathrm{max}}<\lambda}\), the ion can thus be considered as a good approximation to a point-like source. If the temperature of the ion was higher, these results would represent an upper limit for the resolution of the optical system.
The measured intensity PSF, \({I_{\mathrm{PSF}}\equiv \left | \mathrm{PSF}\right |^{2}}\), can be directly related to the Zernike polynomials (see Eqs. (B.2) and (B.4) in Appendix B). Taking into account that Fraunhofer diffraction is the Fourier transform of the generalized pupil function,
Since the modulus is not a bijective function, a direct decomposition of \(I_{ \mathrm{PSF}}\) into the basis of the Zernike polynomials is not possible. Fitting algorithms have been developed to find the best approach [27, 28], which has already been used in a Paul trap [29].
The outcome from the analysis of the ion image is shown in the upper panels of Fig. 4. The magnification was calculated from the ion-ion distance \(d_{\mathrm{ion-ion}}\) in a two-ion Coulomb crystal [30],
where q is the ion charge, \(\varepsilon _{0}\) is the vacuum permittivity, m is the ion mass, and \(\omega _{z}\) is the common axial frequency of the balanced two-ion crystal. The value obtained is \({15.4(1)\times}\), in agreement with the design specifications. Compared to the diffraction-limited case, for which \({\mathrm{FWHM}\approx 0.8}\) μm, the measured image was much broader and strongly asymmetric. A total of 21 Zernike polynomials, up to fifth order in the radial coordinate, were used in the fitting procedure, obtaining a reduced chi-square of \({\chi _{\nu}=3.45}\). Introducing sixth-order Zernike polynomials did not improve the results significantly.
Wave aberration analysis. The data shown in the upper/lower panels were taken before/after implementing the external correction consisting of a cylindrical lens. Both the measured image and the best fit are shown on the left side. The accumulation time for the measured image is 1 s. The weight of the first 21 (piston, X-, and Y-tilt are omitted) Zernike polynomials used in the best fit are shown on the right side. The different colours stand for the five orders in the radial coordinate (see Eq. (B.6) in Appendix B)
Decomposing the image into Zernike polynomials revealed a strong astigmatism, noticeable even in its second-order component. The second most prominent component was coma. Both types of aberration appear when the object is not placed on the optical axis. This is consistent with a misalignment of the optical system with the trap due to machining tolerances at the various anchoring points along the Penning-trap tower. The working distance was correct, as the magnification matches the design value.
Astigmatism can be easily identified by the appearance of two different focal positions for two perpendicular directions due to the different radius of curvature seen by an off-axis object. Following the results shown in the upper part of Fig. 4, a focus scan was performed around the circle of least confusion, observing a difference of 25 mm between two focus points for the trap’s axial and radial directions. This suggested a lateral shift in the position of the optical system from the trap center. Astigmatism can be corrected with a cylindrical lens, which provides focusing only in one direction. A negative lens with \({f'=-400}\text{ mm}\) was chosen, so that the first (tangential) focus point was forced to coincide with the second (sagittal). It was placed about 110 mm behind the image plane and the final configuration was found experimentally by minimizing the ion’s spot radius.
The intensity PSF analysis of the optical system after the insertion of the cylindrical lens is shown in the lower panels of Fig. 4. The first 21 Zernike polynomials were used as in the previous analysis, just to allow a direct comparison. A reduced chi-square of \({ \chi _{\nu}=13.1}\) is obtained, although for the fit using the first 15 polynomials this value decreases to \({\chi _{\nu}=11.5}\). The astigmatism is well attenuated compared to the images shown in the upper panels of Fig. 4, and only some of the coma and trefoil components remain significant. The magnification now becomes \({17.9(1)\times}\), larger than before, justified by the translation of the tangential focus point to the sagittal focus point utilizing the cylindrical lens.
Figure 5 shows the final performance in terms of the PSF and the MTF. Both the images before and after the cylindrical lens inclusion are analyzed. The MTF is calculated directly from the single-ion PSF using FFT (see Eq. (B.8) in Appendix B). The maximum spatial frequencies computed, 580 mm−1 (before the cylindrical lens correction) and 670 mm−1 (after), are limited by the pixel size of 13 μm. As mentioned in Fig. 3, the effect of the detector pixel size is taken into account to determine the real diffraction limit performance (lower dashed line in Fig. 5). The resolution is detailed in Table 1. It should be noted that the intensities are normalized to the maximum value in the PSF comparison. It can be observed that, although the performance improves with the insertion of the cylindrical lens, it does not reach the level measured out of vacuum, which closer to the ideal operation is only limited by diffraction. In principle, the strong astigmatism present in the system could be diminished by a more precise alignment of the optical axis with respect to the trap center. Finally, a seven-ion linear chain is shown in the lower part of Fig. 5. In this particular case, the ions were oscillating at \({\omega _{z}^{\mathrm{com}}=2\pi \times 333\left (1\right )}\text{ kHz}\), resulting in an ion-ion distance in the range \({d_{\mathrm{ion-ion}}=8.01\left (16\right )}\) - \({6.77\left (17 \right )}\) μm.
5 Conclusions
We have designed, characterized, and implemented a new in-vacuum optical system for the detection of single laser-cooled ions using a PMT and an EMCCD in the Penning-trap experiment at the University of Granada. Simulations showing diffraction-limited performance were carried out using the software package Zemax. Out-of-vacuum measurements of the MTF and the CTF using square impulses have shown the near-diffraction-limited performance of the system on the optical axis. For the in-vacuum characterization, a single ion was used as a point-like source to measure the PSF of the system. Wave-aberration retrieval techniques were used to quantify the weight of each type of aberration on the basis of Zernike polynomials. After improving the performance with respect to astigmatism, the resolutions in the axial and radial directions of the trap are 3.69(3) μm and 2.75(3) μm, respectively.
Motional amplitudes as small as 3 μm in the radial plane could be detected using the technique described in Ref. [22]. This is advantageous due to the reduction of the systematics associated with the trapping field imperfections in Penning-trap mass spectrometry. A further reduction of these uncertainties can be achieved by accessing the quantum regime, where well-established procedures already used in quantum optics experiments in RF traps could be employed using the PMT of the optical system [11]. Its high signal-to-noise ratio will be essential to discern between two quantum levels in the timescale of milliseconds.
Data availability
The data that support the findings of this study are available upon reasonable request from the authors.
References
Leibfried D, Blatt R, Monroe C, Wineland D. Quantum dynamics of single trapped ions. Rev Mod Phys. 2003;75:281–324.
Neuhauser W, Hohenstatt M, Toschek P, Dehmelt H. Optical-sideband cooling of visible atom cloud confined in parabolic well. Phys Rev Lett. 1978;41:233–6.
Wineland DJ, Drullinger RE, Walls FL. Radiation-pressure cooling of bound resonant absorbers. Phys Rev Lett. 1978;40:1639–42.
Nagourney W, Sandberg J, Dehmelt H. Shelved optical electron amplifier: observation of quantum jumps. Phys Rev Lett. 1986;56:2797.
Alt W. An objective lens for efficient fluorescence detection of single atoms. Optik. 2002;113:142–4.
Gilmore KA, Affolter M, Lewis-Swan RJ, Barberena D, Jordan E, Rey AM, Bollinger JJ. Quantum-enhanced sensing of displacements and electric fields with two-dimensional trapped-ion crystals. Science. 2021;373:673–8.
Hrmo P, Joshi MK, Jarlaud V, Corfield O, Thompson RC. Sideband cooling of the radial modes of motion of a single ion in a Penning trap. Phys Rev A. 2019;100:043414.
Jain S, Sägesser T, Hrmo P, Torkzaban C, Stadler M, Oswald R, Axline C, Bautista-Salvador A, Ospelkaus C, Kienzler D, Home JP. Penning micro-trap for quantum computing. Nature. 2024;627:510–4.
Cornejo JM, Lehnert R, Niemann M, Mielke J, Meiners T, Bautista-Salvador A, Schulte M, Nitzschke D, Borchert MJ, Hammerer K, Ulmer S, Ospelkaus C. Quantum logic inspired techniques for spacetime-symmetry tests with (anti-)protons. New J Phys. 2021;23:073045.
Berrocal J, Altozano E, Domínguez F, Gutiérrez MJ, Cerrillo J, Fernández FJ, Block M, Ospelkaus C, Rodríguez D. Formation of two-ion crystals by injection from a Paul-trap source into a high-magnetic-field Penning trap. Phys Rev A. 2022;105:052603.
Cerrillo J, Rodríguez D. Motional quantum metrology in a Penning trap. Europhys Lett. 2021;134:38001.
Wineland DJ, Dehmelt HG. Principles of the stored ion calorimeter. J Appl Phys. 1975;46:919–30.
Cornell EA, Weisskoff RM, Boyce KR, Pritchard DE. Mode coupling in a Penning trap: π pulses and a classical avoided crossing. Phys Rev A. 1990;41:312–5.
Gabrielse G, Khabbaz A, Hall DS. Precision mass spectroscopy of the antiproton and proton using simultaneously trapped particles. Phys Rev Lett. 1999;82:3198–201.
Rainville S, Thompson JK, Pritchard DE. An ion balance for ultra-high-precision atomic mass measurements. Science. 2004;303:334–8.
Van Dyck RS Jr, Pinegar DB, Liew SV, Zafonte SL. The UW-PTMS: systematic studies, measurement progress, and future improvements. Int J Mass Spectrom. 2006;251:231–42.
Borchert MJ, Devlin JA, Erlewein SR, Fleck M, Harrington JA, Higuchi T, Latacz BM, Voelksen F, Wursten EJ, Abbass F, Mooser AH, B MA, Popper D, Wiesinger M, Will C, Blaum K, Matsuda Y, Ospelkaus C, Quint W, Walz J, Yamazaki Y, Smorra C, Ulmer S. A 16-parts-per-trillion measurement of the antiproton-to-proton charge–mass ratio. Nature. 2022;601:53–7.
Restrepo MM, Myers EG. Mass difference of tritium and helium-3. Phys Rev Lett. 2023;131:243002.
Schweiger C, Braß M, Debierre V, Door M, Dorrer H, Düllmann CE, Enss C, Filianin P, Gastaldo L, Harman Z, Haverkort MW, Herkenhoff J, Indelicato P, Keitel CH, Kromer K, Lange D, Novikov YN, Renisch D, Rischka A, Schüssler RX, Eliseev S, Blaum K. Penning-trap measurement of the Q value of electron capture in 163Ho for the determination of the electron neutrino mass. Nat Phys. 2024;21:1–7.
Rodríguez D. A quantum sensor for high-performance mass spectrometry. Appl Phys B. 2012;107:1031–42.
Brewer SM, Chen J-S, Hankin AM, Clements ER, Chou CW, Wineland DJ, Hume DB, Leibrandt DR. 27Al+ quantum-logic clock with a systematic uncertainty below 10−18. Phys Rev Lett. 2019;123:033201.
Berrocal J, Hernández A, Arrazola I, Domínguez F, Carrasco-Sanz A, Fernández FJ, Block M, Rodríguez D. Penning-trap eigenfrequency measurements with optical radiofrequency detectors. Phys Rev Res. 2024;6:012001.
Gutiérrez MJ, Berrocal J, Cornejo JM, Domínguez F, Pozo JJD, Arrazola I, Bañuelos J, Escobedo P, Kaleja O, Lamata L, Rica RA, Schmidt S, Block M, Solano E, Rodríguez D. The TRAPSENSOR facility: an open-ring 7 tesla Penning trap for laser-based precision experiments. New J Phys. 2019;21:023023.
Malacara D, Malacara Z. Handbook of optical design. 2nd ed. New York: Dekker; 2004.
Gempel MW, Hartman T, Schulze TA, Voges KK, Zenesini A, Ospelkaus S. An adaptable two-lens high-resolution objective for single-site resolved imaging of atoms in optical lattices. Rev Sci Instrum. 2019;90:053201.
Ball H, Marciniak CD, Wolf RN, Hung AT-H, Pyka K, Biercuk MJ. Site-resolved imaging of beryllium ion crystals in a high-optical-access Penning trap with inbore optomechanics. Rev Sci Instrum. 2019;90:053103.
Iglesias I. Parametric wave-aberration retrieval from point-spread function data by use of a pyramidal recursive algorithm. Appl Opt. 1998;37:5427–30.
Barakat R, Sandler BH. Determination of the wave-front aberration function from measured values of the point-spread function: a two-dimensional phase retrieval problem. J Opt Soc Am A. 1992;9:1715–23.
Wong-Campos JD, Johnson KG, Neyenhuis B, Mizrahi J, Monroe C. High-resolution adaptive imaging of a single atom. Nat Photonics. 2016;10:606–10.
James DFV. Quantum dynamics of cold trapped ions with application to quantum computation. Appl Phys B. 1998;66:181–90.
Goodman JW. Introduction to Fourier optics. 2nd ed. New York: McGraw-Hill; 1996.
Born M, Wolf E. Principles of optics. 7nd ed. Cambridge: Cambridge University Press; 1999.
Acknowledgements
We thank C. Ospelkaus for providing us access to Zemax, which was utilized for the simulations of the new optical system.
Funding
We acknowledge support from Grant No. PID2022-141496NB-I00 funded by MICIU/AEI/10.13039/501100011033 and by ERDF/EU, Grant No. PID2019-104093GB-I00 funded by MICIU/AEI/10.13039/501100011033; from FEDER/Junta de Andalucía - Consejería de Universidad, Investigación e Innovación through Project No. P18-FR-3432, from the Spanish Ministry of Education through PhD fellowship FPU17/02596, and from the University of Granada “Laboratorios Singulares 2020”. The construction of the Ion Traps and Lasers Laboratory was supported by the European Research Council (Contract No. 278648-TRAPSENSOR), Projects No. FPA2015-67694-P (funded by MICIU/AEI/10.13039/501100011033 and by ERDF, EU) and No. FPA2012-32076 (MICIU/FEDER), infrastructure Projects No. UNGR10-1E-501, and No. UNGR13-1E-1830 (MICIU/FEDER/UGR), and No. EQC2018-005130-P (funded by MICIU/AEI/10.13039/501100011033 and by ERDF, EU), and infrastructure Projects No. INF-2011-57131, No. IE2017-5513 and No. IE19_204 UGR (funded by Junta de Andalucía/FEDER).
Author information
Authors and Affiliations
Contributions
J.B. developed the design, performed the measurements, and analyzed the data. D.R. supervised the work and secured the funding. Both authors discussed the results and contributed to the preparation of the manuscript.
Corresponding author
Ethics declarations
Ethics approval and consent to participate
The work was not sent to any other journal. All the authors consented to participate.
Consent for publication
All the authors agree to publication.
Competing interests
The authors declare no competing interests.
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Appendices
Appendix A: Technical specification of the lenses
The objective lenses’ specifications, including one of the field lenses of FL1 (see Fig. 1), are detailed in Table 2.
The specifications of the optical elements used for the relays are listed in Table 3. These parts are symmetric, so only half of the lenses are detailed. As in the case of the objective, one of the field lenses is included.
Appendix B: Evaluation of the performance of an optical system
Given the linearity of the electromagnetic field, the image scalar field \({U_{i} \left (u,v\right )}\) produced by the optical system can be expressed in terms of the object scalar field \({U_{g}\left (\xi ,\eta \right )}\) utilizing the superposition integral,
where \({\mathrm{PSF}\left (u,v;\xi ,\eta \right )}\) is the so-called point spread function (PSF) [31]. If observation takes place on the paraxial image plane, i.e., the lens law is satisfied, the PSF can be expressed in terms of the pupil function of the optical system \(\mathcal{P} \left (x,y\right )\) as
where \({\tilde{\xi}=M\xi ,\tilde{\eta}=M\eta}\) being M the magnification, \(z_{g}\) is the longitudinal distance between the object and the entrance pupil, and \(z_{i}\) between the exit pupil and the image plane [31]. Therefore, the PSF is precisely the Fraunhofer diffraction of the generalized pupil function [31]. Equation (B.2) also implies the space invariance of the PSF, since \({\mathrm{PSF}\left (u,v;\tilde{\xi},\tilde{\eta}\right )\equiv \mathrm{PSF}\left (u-\tilde{\xi},v-\tilde{\eta}\right )}\). The space-invariant \({\mathrm{PSF}\left (u,v\right )}\) is the Fourier Transform of the generalized pupil function from the pupil coordinates \({\left (x,y\right )}\) (at the exit pupil) to the spatial frequency coordinates \({\left (\frac{u}{\lambda z_{i}},\frac{v}{\lambda z_{i}}\right )}\) (at the image plane).
In the ideal case of a non-aberrated circularly-symmetric optical system, the wave aberration W is zero, \({\mathcal{P}\left (x,y\right )}\) is constant over the exit pupil, and the PSF is the Airy disc [32]. In general, W can be expanded into the Zernike polynomials \(Z_{n}^{m}\) as
where r and ϕ are the radial distance and polar angle in spherical coordinates. The Zernike polynomials constitute a system of orthogonal polynomials in the unit circle that, for low orders, have a direct relation to the primary aberrations: defocus, astigmatism, coma, spherical, etc. They are defined as [32]
where
Coming back to Eq. (B.1), the image formation of an extended object will greatly depend on whether the source is coherent or incoherent. The intensity in the image plane for the latter can be computed as [31]
Fluorescence emission by an ion Coulomb crystal is a clear example of incoherent illumination since there is no correlation between the different emission points.
The level of detail that the optical system can reproduce from an object can be quantified by studying the transmission of the spatial frequency f. The modulation transfer function (MTF) is defined as the absolute value of the normalized Fourier transform of the intensity PSF,
and quantifies the relative modulation of the image as a function of the input frequency. It can be demonstrated that aberrations always contribute to decreasing the MTF [31].
Appendix C: Characterization of the performance using a test target
The performance of an optical system can be evaluated by measuring how well it reproduces different spatial frequencies. In this work, and for the out-of-vacuum characterization, we used a 1951 USAF test target (Thorlabs Inc. R1DS1P), which consists of a series of elements with well-defined spatial frequencies. These elements are in the form of three-bar Ronchi rulings and are divided into groups of six elements each, and their spatial frequency is given by \(2^{\mathrm{group}+(\mathrm{element}-1)/6}\). Elements from groups 4, 5, 6, and 7 in the range of 4 mm−1 to 228 mm−1 were used here. Figure 6 shows the test target and illustrates how the optical system images its elements.
Left: Groups 4, 5, 6, and 7 of the 1951 USAF resolution test target. Right: Sketch showing how an optical system reduces the contrast of one of the test target elements. The initial maximum and minimum intensities defined by the white and black levels in the object are only partially reproduced in the image as \(I_{\mathrm{white}}>I_{\max}\) and \(I_{\mathrm{black}}< I_{\min}\)
The measurement procedure consisted in positioning each element at the working distance of the optical system and centering it with its optical axis. Care was taken to align the axes of the target, given by the orientation of the bars, with the axes of the detector, determined by the pixel matrix. The focus position of the sCMOS detector was then adjusted to obtain the sharpest image. Illumination was provided by 397-nm laser light.
For the image of each element, the background was calculated using the square between the second element of group 4 and the first element of group 5 (see Fig. 6) since it is the biggest feature of the target and its intensity is practically constant. The calculation of the contrast transfer function based on Eq. (1) was performed at this stage of the data analysis. The intensities denoted as \(I_{\max}\) and \(I_{\min}\) in Fig. 6 were used.
For further analysis based on the deconvolution of the modulation and contrast transfer functions, the two-dimensional data were normalized to the Frobenius norm. Although the Fast Fourier Transform of each of the two perpendicular three-bar objects is two-dimensional, only the one-dimensional data along the axis perpendicular to the bars contain relevant information about their spatial frequency. The object consists of square impulses, so it has prominent components at the frequency corresponding to the line separation and the odd harmonics. In this work, only the fundamental frequency (\(f_{0}\)) and the third harmonic (\(3f_{0}\)) were analyzed, as all other frequency components can be neglected. Based on the measured image, an ideal object with the same dimensions was recreated. The modulation transfer function for \(f_{0}\) and \(3f_{0}\) was evaluated as the ratio of the measured and ideal components.
To deconvolve the contrast transfer function, we calculated the inner product of the measured image and the ideal object.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License, which permits any non-commercial use, sharing, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if you modified the licensed material. You do not have permission under this licence to share adapted material derived from this article or parts of it. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc-nd/4.0/.
About this article
Cite this article
Berrocal, J., Rodríguez, D. High-performance in-vacuum optical system for quantum optics experiments in a Penning-trap. EPJ Quantum Technol. 12, 58 (2025). https://doi.org/10.1140/epjqt/s40507-025-00357-y
Received:
Accepted:
Published:
DOI: https://doi.org/10.1140/epjqt/s40507-025-00357-y