Results 11 to 20 of about 86,739 (362)

Oxygen metabolism and oxygenation of the newborn [PDF]

open access: yesSeminars in Fetal and Neonatal Medicine, 2020
The premature infant is to some extent protected from hypoxia, however defense against hyperoxia is poorly developed. The optimal assessment of oxygenation is to measure oxygen delivery and extraction. At the bedside PaO2 and SpO2 are approximations of oxygenation at the tissue level.
Andresen, Jannicke Hanne   +1 more
openaire   +4 more sources

Glimmers of Interspecies Resurgence in Public Art: A Reinterpretation of Joanna Rajkowska’s Oxygenator

open access: yesEidos. A Journal for Philosophy of Culture, 2023
The article proposes a new, interspecies interpretation of Joanna Rajkowska’s Oxygenator. Read as what Anna Tsing calls latent commons and problematized through Chantal Mouffe’s concept of agonistic spaces, the canonical piece of public art is shown to ...
Agata Kowalewska
doaj   +1 more source

The ‘oxygen’ in oxygen minimum zones

open access: yesEnvironmental Microbiology, 2022
AbstractAerobic processes require oxygen, and anaerobic processes are typically hindered by it. In many places in the global ocean, oxygen is completely removed at mid‐water depths forming anoxic oxygen minimum zones (A‐OMZs). Within the oxygen gradients linking oxygenated waters with A‐OMZs, there is a transition from aerobic to anaerobic microbial ...
Canfield, Donald E., Kraft, Beate
openaire   +3 more sources

Long-term ECMO, efficiency and performance of EUROSETS adult A.L.ONE ECMO oxygenator

open access: yesJournal of Cardiothoracic Surgery, 2023
Background The management of the oxygenator can be prolonged in the long-term procedures especially during extracorporeal membrane oxygenation (ECMO) for bridge to transplant or bridge to recovery.
Ignazio Condello   +3 more
doaj   +1 more source

Newly Developed Pediatric Membrane Oxygenator that Suppresses Excessive Pressure Drop in Cardiopulmonary Bypass and Extracorporeal Membrane Oxygenation (ECMO)

open access: yesMembranes, 2020
This article developes a pediatric membrane oxygenator that is compact, high performance, and highly safe. This novel experimental approach, which imaging the inside of a membrane oxygenator during fluid perfusion using high-power X-ray CT, identifies ...
Makoto Fukuda   +3 more
doaj   +1 more source

Post-Mortem Extracorporeal Membrane Oxygenation Perfusion Rat Model: A Feasibility Study

open access: yesAnimals, 2023
The development of biomedical soft- or hardware frequently includes testing in animals. However, large efforts have been made to reduce the number of animal experiments, according to the 3Rs principle.
Matthias Manfred Deininger   +7 more
doaj   +1 more source

May oxygen depletion explain the FLASH effect? A chemical track structure analysis [PDF]

open access: yes, 2021
Background and purpose: Recent observations in animal models show that ultra-high dose rate ("FLASH") radiation treatment significantly reduces normal tissue toxicity maintaining an equivalent tumor control. The dependence of this "FLASH" effect on target oxygenation has led to the assumption that oxygen "depletion" could be its major driving force ...
arxiv   +1 more source

An oxygen-reducing biocathode with “oxygen tanks” [PDF]

open access: yesChemical Communications, 2020
Polytetrafluoroethylene submicro-rod, serving as “oxygen tanks” and binders, have been mixed into Os redox polymer-based bilirubin oxidase cathodes, leading to enhanced performance.
Xinxin Xiao   +2 more
openaire   +3 more sources

Experimental studies on coronary perfusion with pump-oxygenator [PDF]

open access: yes, 1959
1. Methods of retrograde coronary perfusion and direct coronary artery perfusion in combination with a bubble oxygenator were investigated in dogs. 2.
Hayashi, Naomi
core   +1 more source

The oxygen trail: tissue oxygenation [PDF]

open access: yesBritish Medical Bulletin, 1999
Aerobic cellular respiration depends on the efficient supply of oxygen and substrate to the mitochondria. There is an oxygen cascade from the environment to the subcellular environment. Efficient oxygen delivery depends on the coordinated interaction between the respiratory and circulatory systems.
M Singer, A T Nathan
openaire   +3 more sources

Home - About - Disclaimer - Privacy