Tower grounding improvement versus line surge arresters: comparison of remedial measures for high-BFOR subtransmission lines [PDF]
This paper presents a technical/economic comparison between remedial measures aimed at improving the lightning performance of an existing Italian three-phase 150-kV overhead line.
GATTA, Fabio Massimo +4 more
core +1 more source
Application and Analysis for Surge Arrester on Lightning Protection of Distribution Network
In order to effectively reduce lightning stroke outage rate, effect of lightning protection with surge arrester on transmission line has been generally acknowledged relative to other lightning protection measures.
Wang Daxing +5 more
doaj +1 more source
Evaluation of a Direct Lightning Strike to the 24 kV Distribution Lines in Thailand
This paper evaluates the effect of a lightning strike directly on the 24 kV distribution lines in Thailand, where such strikes are one of the main causes of power outages.
Pornchai Sestasombut +1 more
doaj +1 more source
Estimation of parameters of metal-oxide surge arrester models using Big Bang-Big Crunch and Hybrid Big Bang-Big Crunch algorithms [PDF]
Metal oxide surge arrester accurate modeling and its parameter identification are very important for insulation coordination studies, arrester allocation and system reliability.
M.M Abravesh +3 more
doaj +1 more source
Lightning Performance on Overhead Distribution Lines : After Improvement Field Observation [PDF]
Two feeders of 20 kV overhead distribution lines which are located in a high lightning density area are chosen to be observed as a field study due to their good lightning performance after improvement of lightning protection system.
Reynaldo Zoro +3 more
doaj
Development and application of lightning flashover limited equipment for 220 kV AC transmission line
In order to solve the operation problems of traditional lightning protection equipment (for example, line arrester and parallel gap) for 220 kV AC transmission line, a novel lightning protection equipment – lightning flashover limited equipment for 220 ...
Wei Cao +6 more
doaj +1 more source
Pemasangan Arrester Multi Chamber Untuk Mengatasi Gangguan Surja Petir di Penyulang Pecatu
Pecatu feeder is a feeder that has a radial distribution system configuration, the length of the line is 31 kms . In addition, these feeders have as many as 105 pieces of distribution transformers with a total number of subscribers reached 11,800 ...
I Gede Gerry Julius Perdana +2 more
doaj +1 more source
Analysis of transmission lightning arrester locations using Tflash [PDF]
Tropical countries with extensive lightning activity, such as Malaysia, encounter numerous problems on their electrical transmission and distribution systems.
Arief, Y. Z. +8 more
core +1 more source
An overview of biodiesel energy [PDF]
Over the last ten years’ attention to biofuels production has increased dramatically and become crucial. One of the main factors is the rise in world oil prices, coupled with the abatement of greenhouse gas emissions and concerns about energy security ...
Abd Halim, Muhamad Fazli +3 more
core
Study on variations in moisture-affected fault characteristics of EMU lightning arrester
In order to study the changes in the fault characteristics of the EMU lightning arresters exposed to moisture, an artificial moisture test platform of lightning arresters was built, on which the lightning arrester can be controlled to reach three states ...
LIU Jian +5 more
doaj