Simulation Experiment on Discharge of Plastic Film Overlapping on UHVDC Transmission Lines
In order to study the discharge phenomena of plastic film overlapping on UHV DC transmission lines and explore the cause of flashover fault of a ± 800 kV UHV line, an experimental study is conducted on the flashover characteristics of plastic film with ...
Shenghui WANG +3 more
doaj +1 more source
800 kV高压交流隔离开关是我国西北电网750 kV输电线路重要的开关设备。文中在国内外高压开关设备研究的基础上,进一步对800 kV高压交流隔离开关进行理论分析研究,确定了800 kV高压交流隔离开关的技术方案及结构参数,建立了800 kV高压交流隔离开关三维模型并进行机械及绝缘特性仿真分析。研制出800 kV高压交流隔离开关样机并通过了型式试验的验证。通过仿真分析和型式试验研究得出,文中设计的800 kV高压交流隔离开关结构合理,机械特性和绝缘特性满足招标要求 ...
李宏楼 +11 more
doaj
Internal charge behaviour of nanocomposites [PDF]
The incorporation of 23 nm titanium dioxide nanoparticles into an epoxy matrix to form a nanocomposite structure is described. It is shown that the use of nanometric particles results in a substantial change in the behaviour of the composite, which can ...
Alison J +20 more
core +1 more source
A model study of corona emission from hydrometeors [PDF]
The maximum measured electric fields in thunderclouds are an order of magnitude less than the fields required for electric breakdown of the air. One explanation for lightning initiation in these low fields is that electric breakdown first occurs at the ...
Abdel-Salam +20 more
core +3 more sources
Generation of energetic He atom beams by a pulsed positive corona discharge [PDF]
Time-of-flight measurements were made of neutral helium atom beams extracted from a repetitive, pulsed, positive-point corona discharge. Two strong neutral peaks, one fast and one slow, were observed, accompanied by a prompt photon peak and a fast ion ...
Blumberg, Seth +6 more
core +1 more source
Power quality disturbances assessment during unintentional islanding scenarios. A contribution to voltage sag studies [PDF]
This paper presents a novel voltage sag topology that occurs during an unintentional islanding operation (IO) within a distribution network (DN) due to large induction motors (IMs).
Bosch Tous, Ricardo +2 more
core +2 more sources
Due to the relatively low operational reliability of the MMC valve, it is necessary to establish corresponding test methods to examine the tolerance of the valve to electrical and thermal stresses under engineering requirements through operational tests,
Qing Liu +4 more
semanticscholar +1 more source
THz generation using a reflective stair-step echelon
We present a novel method for THz generation in lithium niobate using a reflective stair-step echelon structure. The echelon produces a discretely tilted pulse front with less angular dispersion compared to a high groove-density grating.
Huang, W. Ronny +3 more
core +1 more source
Conductor selection and economic analysis of D.R. congo–guinea ±800 kV UHVDC transmission project
Africa is embracing new opportunities featured with industrialization, urbanization and regionalization. Based on co-development of ‘Electricity, Mining, Metallurgy, Industry and Trade’ and grids interconnection proposed by Global Energy Interconnection ...
Zhengxia Chen +4 more
semanticscholar +1 more source
为了提高±800 kV特高压直流输电线路抵御雷害风险能力,研究了±800 kV直流线路避雷器安装选点、基本参数、安装方案和工程应用。文中以±800 kV锦苏线浙江段为工程背景,对其线路走廊落雷情况进行了分析及差异化防雷评估,提出了安装选点原则,开展了避雷器的关键技术参数的理论计算及试验研究,分析了线路避雷器的安装要求,根据安装选点原则配置了避雷器,设计了一种复合绝缘子斜拉式安装方法,成功实施了±800 kV直流线路避雷器的大规模工程应用,对±800 kV直流线路避雷器在其余±800 ...
曹伟 +5 more