Results 41 to 50 of about 924,643 (269)

Research on minimum height above ground considering total and ionized field when ± 800 kV power lines at the high altitude cross the residential areas

open access: yesFrontiers in Energy Research, 2023
Recently, in order to reduce carbon emissions and meet climate change targets set by governments worldwide, which has led to the growth of renewable energy sources, such as wind, solar and hydropower energy, more and more ± 800 kV power lines have been ...
Zhijian Guo   +3 more
doaj   +1 more source

The triggered behavior of a controlled corona stabilised cascade switch [PDF]

open access: yes, 2011
Corona stabilised switches have been shown to have advantages in pulse power switching applications due to their high repetition rates and low jitter.
Given, M   +5 more
core   +1 more source

Novel Tailoring of Ternary ZnS‐MXene‐TiO2 Nanocomposite Heterojunction and Its Tunable Electrochemical Properties With Enhanced Photocatalytic Degradation

open access: yesAdvanced Engineering Materials, EarlyView.
ZnS‐MXene‐TiO2 nanocomposite heterojunction for photocatalytic decomposition of this methylene blue dye (MB) greatly improves light absorption, charge separation, and active site area. Two‐dimensional MXene forms nanocomposites by easily combining them with 0D (quantum dots), 1D (tube and wire), 2D (plane and sheet), and 3D (particle and lamellar ...
Latiful Kabir   +7 more
wiley   +1 more source

Research on Intelligent Inspection System in Enclosed Valve Hall of ±800 kV VSC-HVDC Converter Station

open access: yes南方能源建设, 2019
[Introduction] The real-time monitoring and regular inspection for the primary electrical equipment in valve hall is extremely important to safety operation of converter station. [Method] In this study we investigated the demand of regular inspection of ±
ZHANG Xueyan   +4 more
doaj   +1 more source

Investigation of Oxygen‐Free Wetting Behavior of Aluminum on Copper via Molecular Dynamics Simulations and Experiments

open access: yesAdvanced Engineering Materials, EarlyView.
The wettability of aluminum droplets (Al) on different copper substrates (Cu), where liquid Al spreads on solid Cu surfaces to form a liquid–solid interface, is studied numerically and experimentally. The experimental and numerical results show good agreement in the fast‐spreading regime.
Shan Lyu   +8 more
wiley   +1 more source

800kV罐式金属氧化物避雷器的研制

open access: yesGaoya dianqi, 2011
为了满足国家重点工程"750 kV西宁—永登—白银输变电工程"用800 kV GIS开关设备的需求,笔者开发了800 kV罐式MOA,介绍了交流800 kV SF6罐式无间隙金属氧化物避雷器的性能参数、结构及试验等情况。产品采用高性能电阻片,内部芯体采用Z形结构,用于降低产品的高度。对避雷器的电压和电场分布特性、内绝缘性能、机械强度等关键技术进行了研究。试验结果表明,研制出的避雷器的最大电位分布不均匀系数为11.7%,通过了雷电冲击2 100 kV、操作冲击1 550 kV和工频960 ...
林震, 杨飞军, 赵勇, 赵江涛
doaj  

State estimation applied to active distribution networks with minimal measurements [PDF]

open access: yes, 2005
Traditionally, state estimation is applied to transmission networks to improve security and redundancy of the measurement system. This paper describes the application of state estimation to distribution networks in order to extend the observability of ...
Jenkins, Nick   +2 more
core  

Terahertz radiation by ultrafast spontaneous polarization modulation in multiferroic BiFeO$_3$ thin films

open access: yes, 2005
Terahertz (THz) radiation has been observed from multiferroic BiFeO$_3$ thin films via ultrafast modulation of spontaneous polarization upon carrier excitation with illumination of femtosecond laser pulses.
Kida, Noriaki   +2 more
core   +1 more source

Low‐Angle Grain Boundaries and Re‐Segregation in Single‐Crystalline Ni‐Base Superalloys

open access: yesAdvanced Engineering Materials, EarlyView.
This work demonstrates that Re‐segregation at low‐angle grain boundaries (LAGBs) in Ni‐base superalloys is influenced by misorientation angle. Advanced microscopy and atom probe tomography reveal that higher misorientation angles increases Re‐segregation.
Alireza B. Parsa   +9 more
wiley   +1 more source

一起800 kV断路器绝缘故障的原因分析

open access: yesGaoya dianqi, 2009
笔者对官亭变电站扩建工程中一台800 kV断路器连续两次故障的情况进行了介绍,详细分析了故障的原因,提出了800 kV开关设备需要进一步加强的检查措施,为后续800 kV开关设备提供了质量保障。
孙强
doaj  

Home - About - Disclaimer - Privacy