Results 51 to 60 of about 81,440 (198)
介绍了直流输电工程采用的直流滤波器的类型与构成,分析了±800 kV特高压直流输电工程换流器在直流侧产生的谐波的特点,并与±500 kV高压直流输电工程做了比较。以实际的±800 kV特高压直流输电工程为例,对换流器在直流线路上产生的等效谐波干扰电流进行了计算,对不同直流滤波器设置方案下的滤波效果进行了比较,并以计算结果为依据提出了较为合理的±800 kV特高压直流输电工程直流滤波器设置方案,为最终确定实际工程直流滤波器方案具有一定的参考作用。
张万荣, 任军辉, 王蔚华
doaj
Seismic evaluation of ±800 kV UHVDC disconnect switch by shake table test
Disconnect switches, the widely used electrical substation apparatuses, however, were severely damaged in several earthquakes, causing huge economic losses.
Jiayi Wen, Qiang Xie
doaj +1 more source
Laser‐Induced Graphene from Waste Almond Shells
Almond shells, an abundant agricultural by‐product, are repurposed to create a fully bioderived almond shell/chitosan composite (ASC) degradable in soil. ASC is converted into laser‐induced graphene (LIG) by laser scribing and proposed as a substrate for transient electronics.
Yulia Steksova +9 more
wiley +1 more source
We propose a suture‐complementary approach that integrates optical skin clearing with a strain‐programmable luminescent adhesive patch. Hyaluronic acid promotes transdermal delivery of tartrazine to improve optical clearing and stabilizes its interaction with a photosensitizer. Optical clearing increases the penetration depth of visible light into skin,
Seong‐Jong Kim +6 more
wiley +1 more source
目前±1 100 kV特高压直流系统还没有工程实际,但直流电压由±800 kV提高到±1100 kV后,±1 100 kV直流换流站直流场防雷可能会面临一些新问题。例如线路进线段杆塔比±800 kV更高,绕击和反击电流会更大,导致直流换流站直流场雷电侵入波过电压也会更高,而受设备制造、运输能力和高度的限制,换流站设备的内外绝缘水平并不是按比例线性增大的,这样对±1 100 kV直流换流站直流场的避雷器布置和保护水平提出了更严格的要求。本文依托准东-重庆±1 100 kV直流输电工程 ...
万磊, 范冕, 何慧雯
doaj
Vibration Model of ±800 kV Converter Transformers Under Varying Load Conditions
Understanding the relationship between current harmonics and vibration is crucial for accurately modeling converter transformer vibrations, particularly under varying load conditions. In this study, vibrations of six converter transformers were monitored
Ning Wang, Jing Zheng, Yao Yuan
doaj +1 more source
Multiscale experiments and modeling reveal how Ti3C2Tx MXene nanosheets reinforce PVDF nanocomposites. An optimal MXene loading (∼1 wt.%) nearly doubles tensile strength through efficient stress transfer, flake alignment, and crack‐deflection mechanisms, transforming ductile polymer behavior into a controlled multi‐stage fracture pathway which aligns ...
Bita Soltan Mohammadlou +5 more
wiley +1 more source
This study demonstrates that memristors can replace conventional 2T–1C driving circuits with simplified 1T–1 m architectures by exploiting resistance switching. With ultra‐low switching voltages (< ±0.2 V) and multi‐level resistance states, the memristors precisely control the current injected into organic light‐emitting diodes (OLEDs).
Dong Hyun Kim +6 more
wiley +1 more source
由发电机出线直接升压到800 kV的变压器将在西北地区首次采用。该文将结合拉西瓦工程设计的要求,对一系列的技术问题加以研究与分析。根据工程设计和研究结果,变压器将采用三相组单相变压器,铁心采用三柱式,电压调压范围为800/!3-3×2.5%kV。由于GIS的断路器和隔离开关均设置分合闸电阻,使GIS产生的快速暂态过电压(VFTO)对变压器绝缘影响较小,以及我国800 kV系统过电压的限制水平,确定它的绝缘耐受能力。
阮全荣, 施围
doaj
Significant nanoscale oxygen diffusion coefficient variations are measured in ferroelectric hafnium zirconium oxide films with grain boundaries and electrode interfaces exhibiting values 104 times larger than the grain cores. Overall coefficients are 10X larger for films prepared with metal nitride electrodes compared to refractory metals. New insights
Liron Shvilberg +6 more
wiley +1 more source

