Results 21 to 30 of about 81 (60)
阐述了应用ATP软件对变压器各种工况进行仿真的过程,包括变压器模型的选择、模型参数的计算、仿真结果的分析。通过和动模实验结果的比较,验证了仿真结果的准确性。
王雪, 王增平, 徐岩
doaj +1 more source
Research on Startup of DC Transformer for Electric Vehicle Cluster Grid-Connection [PDF]
Modular multilevel direct current transformer (MMDCT) provides a feasible solution to realize the efficient and stable integration of electric vehicle charging and discharging cluster into urban DC distribution network.
FAN Weihao +6 more
core +1 more source
Application and Prospect of Flexible Transmission and Distribution Technology in Internet Data Center [PDF]
[Introduction] As an important thrust of China's "new infrastructure", internet data centers have ushered in opportunities for vigorous development and become new areas of energy use, putting forward higher requirements for the power supply level and ...
Deyang CHEN +7 more
core +1 more source
从本质上介绍了不接地系统到电阻或消弧线圈接地系统的演变过程;引出了接地变和接地变兼站用变的概念,解释了接地变、接地变兼站用变的构造和原理;遵照国家标准,并借鉴项目经验,总结了通过接地变兼站用变铭牌参数确定短路阻抗选取基准侧的方法,并且结合实例给出了详细的解释推导,奠定了接地变兼站用变的短路电流计算,继电保护整定计算的计算基础;基于确定基准侧后的短路电流计算,分析了接地变兼站用变与普通接地变的速断保护整定计算的差异,分别从躲过变压器低压侧出口三相短路 ...
志磊 辛
core +1 more source
特高压直流输电系统在受端交流故障情况下的换相失败仿真结果有时会与实际运行情况有所差异,其原因之一在于仿真模型没有计及实际工程中使用的换相失败预测控制。在阐述特高压天中直流工程发生的两起特殊事件的基础上,详细分析了换相失败预测控制模型对特高压直流仿真结果的影响,通过搭建包含换相失败预测控制的直流输电模型对这两起事件进行了准确的仿真反演,发现换相失败预测控制在交流系统励磁涌流下会频繁动作,造成直流功率波动,并提出了能躲过励磁涌流的换相失败预测控制改进措施,仿真验证了该改进措施的有效性。
李程昊 +4 more
doaj +1 more source
Diagnosis of Power System Defects by Large Language Models and Graph Neural Networks [PDF]
Defect ratings and analysis and processing of different devices and equipment in the power system are often affected by the subjectivity of operation and maintenance personnel, resulting in different severity ratings for the same defect text description.
LI Li, SHI Rongliang, GUO Xu, JIANG Hongxin
core +1 more source
为减少电力系统中断路器投切开关的分闸燃弧和合闸涌流,设计了一种永磁机构断路器的选相分合闸控制系统.系统通过真空继电器的二级驱动方式保证了机械动作时间可控且离散性小,解决了单级接触器驱动方式的机械动作时间离散性大和单级晶闸管驱动方式的驱动电路复杂性的问题.系统以STM32单片机为控制核心,通过电流突变捕捉时刻算法准确捕捉到分合闸动作完成时刻,进而计算出上一次的分合闸机械动作过程时间,预测出下一次的分合闸机械动作时刻,实现了控制系统根据设定的分合闸相角对断路器准确地进行分相投切控制的功能 ...
李钷 +4 more
core
电力变压器是电网中至关重要的元件,并且是变电站中最昂贵的设备。如果空载时突然把变压器投入电网,由于变压器的非线性,在合闸瞬间会产生很大的励磁涌流,其幅值可达稳态时的几十倍或更高。通常励磁涌流的衰减速度要比短路电流的衰减速度更慢,在上述高幅值的励磁涌流下,很容易引起变压器差动保护装置误动、绕组机械应力增大以及电能质量降低等问题,而真空断路器的选相合闸能很好的解决这个问题。文中在某大功率试验站的6 kV网络试验回路上采用12 kV快速真空开关进行了空载变压器的合闸试验,试验中测量了真空断路器随机合闸 ...
王昊晴 +8 more
doaj
为了满足10 kV配电系统用户分支线的实际情况和保护需求,研制了一种专用保护跳闸的涌流控制器,给出了10 kV馈线涌流控制器的硬件设计框图和软件流程。根据差动电流的全波傅氏算法和半波傅氏算法的计算结果及励磁涌流与内部故障电流的差异,提出了一种基于差动电流波形特征的励磁涌流识别新方法。理论分析和仿真试验结果表明,该方法能够快速区分励磁涌流和内部故障电流。同时,较好地克服了传统制动原理的缺点,并提高了差动保护的可靠性和安全性。电磁兼容实验也证明该控制器具有抗干扰等优点。
闫鸿魁, 林莘, 徐建源
doaj
电力变压器铁心中存在剩磁时,将加速铁心的磁化饱和,导致空载合闸时励磁涌流过大,严重影响变压器和电网的安全、稳定运行。准确测量剩磁是避免励磁涌流危害电网安全的重要工作。文中主要介绍了现有的几种测量剩磁的方法:经验估计剩磁、基于铁心磁化模型的计算方法、电压积分法、基于励磁涌流的剩磁测量方法和基于漏磁的剩磁测量方法,分析了其工作原理、适用范围、优缺点以及需要解决的问题,并对剩磁测量方法的发展方向进行了展望。
李景丽 +4 more