Results 21 to 30 of about 34,757 (154)
利用共振型声学超表面吸声是近年来噪声控制的研究热点,然而其狭窄的吸收峰限制了进一步应用。针对电磁噪声在中低频噪声峰分布呈现倍数关系的特点,基于Visco-Thermal长直管吸声原理设计了六棱柱状的共面迷宫腔声学超表面单元结构,厚度仅为波长的1/137,可以用一种结构实现对多个噪声峰值的吸收。利用不同单元结构的并联,实现了对更多噪声峰值的覆盖。以变压器噪声为例,用并联的共面迷宫腔声学超表面结构实现对800 Hz以下所有整数阶谐频噪声的吸收,分析了结构参数对吸声效果的影响规律并进行了原理性实验验证。
王广周 +4 more
doaj
The Johnstone's whistling frog is an invasive species whose loud night‐time calls may affect human health and well‐being. Our study in Cali, Colombia, combined fieldwork and online surveys to assess its urban occupancy, density, and potential health impacts.
Rubén Darío Palacio, Sumana Goli
wiley +1 more source
ABSTRACT Fluxgate sensors with Co‐rich amorphous microwires, widely used for their low noise in magnetic field measurements, encounter significant challenges in high‐temperature environments such as well drilling and geological exploration. Prolonged thermal aging degrades the performance of Co‐rich amorphous microwires, resulting in increased noise ...
Lining Pan +10 more
wiley +1 more source
一、前言噪声对人体的影响是复杂的而且是多方面的。如所周知,它除直接损害听觉器官引起噪声性耳聋之外,还产生所谓噪声对“非听觉”的影响,这主要表现在心血管系统和神经系统等方面。大量的调查研究业已证明,人们长期处于高噪声的环境下,最常见的表现之一是出现神衰症候群。为了观察噪声对中枢神经系统的影响,有些学者曾经对噪声作用后脑电图的变化进行过实验研究 ...
封根泉, 宋子中
core +1 more source
变压器外部噪声控制系统对提升变电站声环境质量具有重要意义。噪声控制系统的布放位置和结构参数选择需要依据变压器空间噪声的干涉衰减和频谱特性。目前对变压器不同位置噪声干涉衰减规律的研究很少。文中测量了山西省内某1 000 kV特高压变压器噪声,研究了变压器A、B、C相以及AB、BC相中间位置噪声干涉衰减规律。变压器A、B、C相声压级随测量点到变压器立面距离增加单调下降,略有波动,分为快衰减段和慢衰减段。变压器AB、BC相中间位置,由于近场干涉作用出现明显的振荡段。在振荡段高频分量单调下降 ...
张超, 刘国强, 芦竹茂, 俞华
doaj
Domain‐adaptation‐based named entity recognition with information enrichment is proposed for developing an equipment fault knowledge graph. A question answering application of the equipment fault knowledge graph is proposed. Abstract Numerous files, such as records and logs, are generated in the process of equipment diagnosis and maintenance (D&M ...
Dengrui Xiong +3 more
wiley +1 more source
为了掌握特高压交流GIS变电站的噪声特性,以1 000 kV特高压芜湖变电站为研究对象,对站内主变压器、高压并联电抗器以及站界噪声声压级进行了测量,分析了站内主要噪声源的频谱分布、噪声水平以及噪声传播与衰减特性。结果表明,主变压器噪声与高压并联电抗器噪声较为接近且以中低频为主,均在70 dB(A)左右。冷却风扇噪声对主变压器噪声影响较大。主变压器与高压并联电抗器噪声传播过程中均存在较为明显的干涉现象,其中以100、200 Hz噪声干涉最为显著。站界噪声受站内声源位置的影响较大,距离噪声源越近 ...
吴晓文 +4 more
doaj
为了降低变压器噪声给人们工作和生活带来的影响,笔者较全面地阐述了变压器噪声控制的重要意义和这些年来国内外的研究成果,说明了振动是产生变压器本体噪声和冷却装置噪声的原因。归纳了变压器噪声的研究方法:变压器远场辐射噪声可以通过实测数据统计和建立计算模型两类方法进行分析,变压器辐射噪声的测量用声强法比传统的声压法更加接近真实情况。详细介绍了变压器的噪声控制方法,在噪声源控制上选用优质高取向硅钢片,在设计、工艺和安装等诸多方面采取有效措施降低噪声;在噪声传播过程中采用缓冲装置、消声法、设置隔音层 ...
谭闻, 张小武
doaj
混沌噪声与白噪声对Van der Pol振荡器相位噪声的影响
从描述振荡器的非线性微分方程出发,提出将噪声作为非线性微分方程的一项,通过建立随机非线性微分方程来分析振荡器的相位噪声.并用这种方法,在相同强度下,针对分别为白噪声和混沌噪声的情形,分析了Van der Pol振荡器产生的相位噪声,发现混沌噪声产生的相位噪声要远大于白噪声所产生的相位噪声.通过分析其原因,提出了一些低相位噪声振荡器设计所应考虑的问题.
严刚峰, 谭航, 徐宁璟, 黄显核
doaj