Results 31 to 40 of about 495,507 (143)
均压电极是高压直流输电工程换流阀内冷水系统的重要部件,起到钳制电势和减小泄漏电流的关键作用,但是在运行过程中,均压电极发生腐蚀或者断裂,将导致换流阀阀塔上与内冷水管道接触的金属器件发生腐蚀,内冷水系统发生渗漏、堵塞等,从而使得换流站因设备过热、水管漏水等问题造成的停运事件屡有发生,严重影响直流工程的安全稳定运行。因此,研究均压电极断裂相关机理和原因能够有效减小内冷水系统事故。文中通过分析均压电极在水管内的受力情况,结合铂金材料的特性,首次从剪切强度的角度开展了均压电极断裂分析。文中从材料成分、力学性能 ...
肖凯 +5 more
doaj
ABSTRACT Public consultations are a cornerstone of democratic policymaking, yet the sheer volume and heterogeneity of submissions often overwhelm traditional analysis. Emerging large language models (LLMs) offer new opportunities for making sense of such data, but their performance in contexts with high linguistic and technical diversity remains ...
Edgar Mathevet, Lauriane Cailleux
wiley +1 more source
Enhanced Corrosion Resistance in an Additively Manufactured Copper Alloy via Suppressed Segregation
ABSTRACT This study elucidates the corrosion behavior of C18150 Cu–Cr–Zr alloy fabricated by laser powder bed fusion (LPBF) in comparison with a conventional wrought baseline representative of industrial Cu–Cr–Zr plate products, highlighting the superior corrosion resistance of the additively manufactured condition.
Yang Qi +4 more
wiley +1 more source
根据城轨供电系统的特点分析了雷击城轨整流变电站附近杆塔时对整流变电站的影响方式,认为与铁轨并联的均流线和接触网末端的绝缘配置会引起雷击杆塔时过电压入侵到整流变电站,而整流变电站避雷器接地散流效果和均压效果不好是引起整流变电站事故的主要原因。针对避雷器接地和均流线接地散流和均压不良设计了新的接地装置,并用ANSYS软件对比分析了新的接地装置和原有接地装置的接地性能,分析结果表明:新型接地装置的均压效果相对于原有接地装置的均压效果其最大地电位减小了28 ...
张东, 陶凤源, 董新胜
doaj
Identical Platform, Divergent Publics: Sweden and Finland During the 2022 NATO Crisis
ABSTRACT Digital platforms are often theorized as universal drivers of political polarization, yet empirical patterns remain inconsistent across countries. Leveraging the natural‐experiment logic of Sweden's and Finland's simultaneous 2022 NATO applications and the NATO–Turkey diplomatic crisis, this study examines how national political cultures ...
Selcen Ozturkcan
wiley +1 more source
ABSTRACT This paper examines the impact of the COVID‐19 pandemic on income and wealth inequality in Switzerland, with a particular focus on poverty dynamics and the role of the social security system. Using newly linked administrative tax data for four large cantons covering over a third of the Swiss population, we track changes in household income and
Oliver Hümbelin +2 more
wiley +1 more source
选取昆明市松华坝水源区典型小流域——迤者小流域为试验区,通过布设标准径流小区,在2009—2015年对坡耕地产流产沙及氮、磷流失情况进行长期的野外观测研究,从年际尺度上来探讨等高反坡阶对于坡耕地产流产沙及氮、磷等养分流失的影响。结果表明:等高反坡阶对于径流和泥沙的削减效果均较为明显,年平均减流率为50.64%,年平均减沙率74.99%,减沙率显著大于减流率;等高反坡阶对于径流和泥沙中氮、磷均有较为明显的削减效果,平均每年可以削减68.75%的氮流失和82.16%的磷流失 ...
王帅兵, 王克勤
doaj
ABSTRACT NiCoCrAlYTa coatings are widely used as bond coats in thermal barrier coating (TBC) systems for gas turbines and aeroengines to provide oxidation resistance and support the formation of a protective thermally grown oxide (TGO). Herein, high‐current pulsed electron beam (HCPEB) modification was utilized to strengthen a NiCoCrAlYTa coating by ...
Xiangcheng Li +6 more
wiley +1 more source
发生直流线路接地或极母线接地故障时,直流中性母线避雷器将产生很大的能量,为满足能量要求,中性母线避雷器采用了多柱并联的结构。为避免电流分配不均使某一柱避雷器阀片吸收能量过大损坏,必须严格控制多柱并联避雷器的电流分布不均匀系数。目前判断多柱并联避雷器均流特性优劣的方法为测试通过单柱1001 000 A的雷电冲击电流下的不均匀系数不大于1.1。而通过直流中性母线避雷器的电流波形与测试采用的波形相差较大,文中结合直流中性母线避雷器典型电流幅值和波形,开展电流分布试验,验证电流分布特性是否符合要求 ...
卢文浩 +3 more
doaj

