Results 1 to 10 of about 1,290 (110)
针对中国第一个海上风电柔性直流送出工程—江苏如东工程,从系统拓扑方案构建、过电压与绝缘配合、系统功率盈余问题与交流故障穿越技术以及控制保护技术等方面开展了深入研究,构建了轻型紧凑化的海上风电柔性直流系统拓扑方案,取消了海上换流站的启动回路与接地回路等;提出了海陆换流站的避雷器配置方案与参考电压的选取原则,形成了海陆换流站的绝缘配合方案的典型范式;提出了集中式、分布式、混合式直流侧有功功率动态平衡装置的典型拓扑方式,解决了陆上换流站交流侧故障穿越难题;提出了工程的整体控制保护方案 ...
卢亚军 +6 more
core +1 more source
针对使用广泛的500 kV架空输电线路,分别研究了在轻、中、重冰区,由断线及不均匀覆冰引起的导线张力对输电杆塔安全性和经济性的影响。研究表明:导线张力增加0~20%,若保持杆塔杆件规格不变,悬垂塔的超限杆件比例为0~51%,耐张塔的超限杆件比例为0~4%;若增大杆塔杆件规格以保证安全,悬垂塔的塔重增加0~28%,耐张塔的塔重增加0~5%;覆冰越厚,由断线引起的导线张力对杆塔影响越小,由不均匀覆冰引起的导线张力对杆塔影响越大;导线张力主要影响悬垂塔横担上、下平面交叉材、塔身主斜材等杆塔杆件。因此 ...
张林枫 +6 more
core +1 more source
Research on the Key Parameters and Device Capacity Decoupling Analysis of Full Bridge MMC DC Ice-Melting Device [PDF]
[Introduction] This article aims to study the issue of the melting capacity and reactive output capacity of the full bridge modular multi-level converter (MMC) type DC (Direct Current) melting ice device under different operating modes.
Rui HE, Xiaogang WU
core +1 more source
Research on Lightning Performance and Protective Measures of ±800 kV UHVDC Power Transmission Line [PDF]
[Introduction] Lightning strike is the primary cause of failures of ±800 kV UHVDC power transmission lines, and the lightning protection assessment of power transmission lines is critical to the safe and stable operation of the system.
Youjun GONG, Zhiwen HE, Ziwei YAN
core +1 more source
为提升远海风电对称双极柔性直流送端交流系统单相接地故障和两相短路故障工况(第一类故障)下的功率输送能力,以及三相接地故障工况(第二类故障)的交流电压稳定性,提出海上换流站协调控制策略。首先分析了第一类故障的过电压和极间环流产生机理,以及第二类故障的交流电压失稳机理。在此基础上,提出了功率平衡控制策略和输出有功电流策略。第一类故障下定电压控制极采用限压策略,功率平衡控制策略抑制极间环流,增大定电压控制极的功率,减少了交流电压控制器响应时间,提升了功率输送能力。第二类故障工况下 ...
叶荣 +4 more
core +1 more source
Discharge characteristics and discharge simulation model of long air gaps containing a floating conductor [PDF]
Long air gaps containing a floating conductor are common insulation types in power grids. During the transmission line live-line work, the process of lineman entering the transmission line air gap constitutes a live-line work combined air gap, which is a
Gao, Jiachen <1995>
core +1 more source
空心复合绝缘子是高压电器设备的重要外绝缘部件,其端部连接结构对产品机械性能影响很大。目前常见的端部连接结构有间隙配合和过盈配合两种,但相关对比研究很少。笔者以某典型规格500 kV空心复合绝缘子为研究对象,采用有限元仿真分析和分组试验的方式,研究了不同端部连接结构的弯曲特性。研究结果表明,当施加相同弯曲负荷时,间隙配合绝缘管承受的应力比过盈配合大,间隙配合最终的破坏值会相对偏小。主要尺寸相同的两种端部连接结构样品,过盈配合弯曲破坏值比间隙配合弯曲破坏值高约11.6%。
韦晓星 +7 more
doaj
The Two Faces of Introgression in Conservation Biology 基因渗入在保育生物学中的双重面貌
Conservation biologist need to take into account the various aspects of introgression in their attempts to protect the species integrity and evolutionary potential of threatened species. To do so, they have to overcome the bias created by the Mayrian species concept that considers species as having distinct gene pools.
Harald Schneider, Charles H. Cannon
wiley +1 more source
State Grid's Qinghai-Tibet Grid Project Based on Responsibility Infrastructure Mode [PDF]
本刊从2008年起一直在跟踪报道国家电网公司省级公司、市级公司、县级公司的三级全面社会责任管理试点工作的成绩和进展,而与此同时,国家电网公司总部的全面社会责任试点也正在如火如荼地展开。自2008年开始,国家电网公司积极探索将社会责任全面融入电网建设的有效路径,经过几年的努力,初步总结了“坚持一大目标、贯彻四大要求、覆盖四大环节、落实五大支撑“的“责任基建“模式。这个模式的典型体现,就是造就了一条高度负责任的“电力天路 ...
李伟阳
core
基于电力细分业务抽样调查的满意度模型,使用电力用户近3个月办理过的电力细分业务和美国客户满意度模型指标设计个性化问卷,并采用分层Neyman抽样方法、补抽算法和结构方程模型客户满意度指数算法测算电力企业各子业务的满意度测评得分。基于问卷调查数据结果,分析不同业务部门细分业务的满意度得分与客户期望之间的差距,为改进具体业务提供详细的解决方案 ...
吴育青, 罗智超
core

