Results 1 to 10 of about 293,651 (151)

Synthesizing habitat connectivity analyses of a globally important human‐dominated tiger‐conservation landscape

open access: yesConservation Biology, Volume 36, Issue 4, August 2022., 2022
Abstract As ecological data and associated analyses become more widely available, synthesizing results for effective communication with stakeholders is essential. In the case of wildlife corridors, managers in human‐dominated landscapes need to identify both the locations of corridors and multiple stakeholders for effective oversight.
Jay M. Schoen   +13 more
wiley   +1 more source

基于输电线路最大输电能力的输电网合理利用率评估 [PDF]

open access: yes全球能源互联网, 2021
能源转型背景下新能源的迅猛发展给电力系统带来更多不确定性,如何评估在此形势下电网规划方案的合理性是一项重大挑战。输电线路利用率是评价输电资源利用的关键指标,但传统利用率指标通常以热稳定极限功率为参照,忽略了电网运行状态对线路输电能力的影响,无法从指标本身分析输电资源利用水平受限的原因。在系统安全约束限制下,输电线路最大输电能力(total transfer capability,TTC)一般小于热稳定极限功率。对输电线路TTC的计算方法进行了研究,以最优潮流模型为基础 ...
杨钤, 王建学, 林帆, 张耀
doaj   +1 more source

导线张力对输电杆塔安全性和经济性的影响研究 [PDF]

open access: yes, 2023
针对使用广泛的500 kV架空输电线路,分别研究了在轻、中、重冰区,由断线及不均匀覆冰引起的导线张力对输电杆塔安全性和经济性的影响。研究表明:导线张力增加0~20%,若保持杆塔杆件规格不变,悬垂塔的超限杆件比例为0~51%,耐张塔的超限杆件比例为0~4%;若增大杆塔杆件规格以保证安全,悬垂塔的塔重增加0~28%,耐张塔的塔重增加0~5%;覆冰越厚,由断线引起的导线张力对杆塔影响越小,由不均匀覆冰引起的导线张力对杆塔影响越大;导线张力主要影响悬垂塔横担上、下平面交叉材、塔身主斜材等杆塔杆件。因此 ...
程述一   +6 more
core   +2 more sources

International clinical practice recommendations on the definition, diagnosis, assessment, intervention, and psychosocial aspects of developmental coordination disorder – Chinese (Mandarin) translation

open access: yesDevelopmental Medicine &Child Neurology, Volume 61, Issue 3, Page E1-E35, March 2019., 2019
目的 本国际临床指南由欧洲残疾儿童学会(the European Academy of Childhood Disability,EACD)牵头制定,旨在解决发育性协调障碍(developmental coordination disorder,DCD)的定义、诊断、评估、干预以及与社会心理方面的临床应用关键问题。 方法 本指南针对五个领域的关键问题,通过文献综述和专家团队的正式讨论达成共识。为保证指南的循证基础,以“机制”、“评估”和“干预”为检索词, 对2012年更新以来提出的最新建议以及新增的“社会心理问题”和“青少年/成人”为检索词进行检索。根据牛津大学循证医学中心证据等级 (证据水平 [level of evidence, LOE]1–4) 将结果进行分类,最终转化为指南建议。并由国际 ...
Jing Hua   +6 more
wiley   +1 more source

混压输电线路耐雷性能研究

open access: yesGaoya dianqi, 2021
同塔混压输电在增大输电容量、节约线路走廊资源和减少建设成本方面具有巨大优越性和发展前景。近年来对于特高压与超高压同塔混合输电开展的前期研究发现,多回输电线路之间存在电磁耦合,影响输电线路的过电压水平。因此需对超、特高压混压输电线路的耐雷水平进行重新评估,以确保输电安全。文中以单回±800 kV与双回500 kV交直流同塔输电线路为研究对象,应用ATP-EMTP软件搭建线路分布式参数模型,并对雷电流、杆塔、波阻抗等分别建立仿真模型,分析了雷电反击与绕击时架空线路上产生的感应过电压特性 ...
曾诚   +4 more
doaj  

架空输电线路雷击暂态过电压分布规律模拟研究

open access: yesDianci bileiqi, 2022
研究架空输电线路雷击暂态过电压分布规律,为架空输电线路的防雷保护和绝缘设计提供可靠依据。使用Marti线路模型分析架空输电线路的频变特性;利用电晕模型模拟电晕效应,使用镜像法推导输电线路几何电容表达式,计算电晕出现时线路的动态电容。在ATP-EMTP电磁暂态仿真软件中研究线路感应暂态过电压和雷电绕击过电压的暂态分布规律,研究绕击过电压的影响因素。模拟仿真结果表明:同时考虑冲击电晕效应和线路参数频变特性能够更加准确计算出输电线路过电压分布规律;出现雷绕击故障的A相线路电压高于未发生故障的B、C相线路 ...
赵留学, 王建荣, 谭磊
doaj  

Time‐Efficient Columnar‐to‐Equiaxed Transition via High Magnetic Field Processing

open access: yesRare Metals, Volume 45, Issue 9, September 2026.
ABSTRACT The need to simplify processing routes and improve processing efficiency motivates the development of time‐efficient methods for inducing the columnar‐to‐equiaxed transition (CET) during solidification while tailoring material performance. Conventional multistep CET approaches are time‐consuming and often struggle to simultaneously regulate ...
Chendong Zhao   +12 more
wiley   +1 more source

Broad‐Spectral Response Lead Halide Perovskite Solar Cells Through Integration of Multifunctional Organic Bulk‐Heterojunction and Quantum‐Cutting Downconversion Materials

open access: yesRare Metals, Volume 45, Issue 3, March 2026.
ABSTRACT Expanding near‐infrared (NIR) spectral response and utilizing ultraviolet (UV) photons are effective strategies for enhancing the power conversion efficiency (PCE) of lead halide perovskite solar cells (PSCs). However, the range of NIR spectral response extension and the utilization of UV light for devices are not enough, and the loss of ...
Li He   +9 more
wiley   +1 more source

雷击输电线路对并行10 kV配电线路影响分析

open access: yesGaoya dianqi, 2019
由于线路走廊有限,10 kV配电线路与输电线路会出现并行架设,需要分析输电线路遭受雷击后对配电线路防护产生的影响。文中分析输电线路避雷线遭受雷击对配电线路的电磁影响及输电线路对配电线路的屏蔽保护作用,利用EMTP软件建立输电线路与配电线路模型,计算雷击输电线路避雷线时配电线路感应过电压,分析避雷线高度、线路间水平间距、线路高度差和输电线路杆塔接地电阻对感应过电压的影响。分析结果表明:雷击输电线路避雷线时,配电线路感应过电压随着避雷线高度的增加而降低,但降低趋势趋缓。过电压随着二者间水平距离的增大而减小 ...
申东玄, 杨仲江, 刘健, 肖扬
doaj  

减少季风对输电线路绕击影响的研究

open access: yesDianci bileiqi, 2014
根据对平原地区输电线路绕击问题分析,发现雷电绕击输电线路多发生在风向与输电线路垂直的地区,由此可见风向风速对输电线路的绕击影响较大。首先分析了风速对输电线路避雷线保护角的影响,得出风会使输电线路背风侧的避雷线保护角增大;同时计算了风速与输电线路绕击率的关系,认为在风速大于10 m/s时,220 kV输电线路的绕击率开始有较大的增加。最后针对风会使输电线路背风侧避雷线保护角增大的问题,根据某地风速统计资料和风向玫瑰图,提出了在输电线路走向与雷电季节风向垂直段采用避雷线不对称保护角来减小风速其影响 ...
张东, 董新胜, 陶凤源, 王世荣
doaj  