Results 41 to 50 of about 160,422 (158)

Social Determinants of Sepsis Mortality in the United States: A Retrospective, Epidemiologic Analysis

open access: yesWorld Medical &Health Policy, Volume 17, Issue 4, Page 823-830, December 2025.
ABSTRACT Sepsis is a leading cause of mortality in the United States, with over 350,000 deaths annually, yet the contribution of neighborhood‐level social determinants of health (SDoH) remains underexplored. We conducted a retrospective analysis of 4.4 million hospitalized patients with sepsis, identified using ICD‐10 codes, leveraging de‐identified ...
Ahad Khaleghi Ardabili   +3 more
wiley   +1 more source

非均质材料准脆性损伤断裂的广义梁链网模型

open access: yes, 2016
陶瓷、岩石和混凝土等非均质材料的准脆性损伤断裂,既不同于玻璃的理想脆性断裂,又有别于金属材料的韧性断裂。本研究建立了该类材料的微观断裂力学模型——广义梁链网模型~([1,2]),根据应力重分配的思想实现渐进失效的模拟。重点考虑了三个方面的问题:1.微结构预应力的影响~([3,4])。微结构预应力是指混凝土风干过程中基体与骨料间的非协调变形导致的初始非零应力场。研究表明,微结构预应力可显著提升材料的延展性,并且造成卸载后不可恢复的变形。2.惯性效应~([5,6])。在新裂纹生成的瞬间 ...
梁乃刚, 刘金兴
core   +2 more sources

焊接残余应力对加强型节点力学性能影响研究

open access: yesJianzhu Gangjiegou Jinzhan, 2013
以翼缘板加强式和盖板加强式两类加强型节点为研究对象,采用ANSYS结构分析软件"生死单元"功能模拟了瞬态焊接过程,得到焊接残余应力场的分布,在此基础上,针对有、无考虑焊接残余应力的两种有限元模型,分析了残余应力对节点和荷载-位移滞回性能及脆性断裂特性等影响。研究结果表明,焊接残余应力对盖板加强型节点的脆性断裂影响大于翼缘板加强型节点,盖板加强式节点在梁端对接焊缝的边缘容易发生脆性断裂,在设计和施工时应予以注意并采取相应的防范措施。
刘芸, 王燕, 王薇
doaj  

Finding floral and faunal species richness optima among active fire regimes

open access: yesConservation Biology, Volume 39, Issue 6, December 2025.
Abstract Changing fire regimes have important implications for biodiversity and challenge traditional conservation approaches that rely on historical conditions as proxies for ecological integrity. This historical‐centric approach becomes increasingly tenuous under climate change, necessitating direct tests of environmental impacts on biodiversity.
Zachary L. Steel   +8 more
wiley   +1 more source

110kV复合绝缘子脆断原因分析及对策

open access: yesDianci bileiqi, 2000
从复合绝缘子端部应力分布、破坏过程和蠕变破坏及运行环境等方面 ,分析了复合绝缘子发生脆断的原因 ,提出了改进措施及工程应用中应注意的问题。指出在该地区转角杆塔 ...
郑春生, 杜正旺
doaj  

Analysis on the temporal and spatial characteristics and causes of mass deaths in the Yangtze River Basin in the Ming dynasty(明代长江流域人口大量死亡事件时空特征及原因分析)

open access: yesZhejiang Daxue xuebao. Lixue ban, 2022
通过检索古籍文献,整理了明代(公元1368—1644年)长江流域人口大量死亡事件(mass death events,MDE)10 a尺度的频次与县次序列,利用自然断点分级法、空间分析法等分析了MDE的时空特征及发生原因。结果表明:276 a间,长江流域有158 a发生MDE,明代后期发生频次和影响规模最大;季节上,表现为夏季多发(44.3%),春、秋季次之;空间上,集中分布于长江中下游、尤其是长江三角洲地区,且呈从各省交界处向各省中心扩散的趋势。“未记录原因的饥荒”和“旱灾+其他灾害-饥荒 ...
WUZiyu(毋子玉)   +3 more
doaj   +1 more source

Policy Effectiveness in Managing Drug Shortages: Evidence From South Korea (2015–2024)

open access: yesWorld Medical &Health Policy, Volume 17, Issue 3, Page 561-572, September 2025.
ABSTRACT Drug shortages represent a growing policy challenge for healthcare systems worldwide. This study investigates actual drug shortage events in South Korea from 2015 to 2024, using a “Shortage Occurred vs. Shortage Non‐Occurred” framework to distinguish real‐world disruptions from administrative classifications.
Seung‐Rae Yu
wiley   +1 more source

Social protection and resilience in protracted crises

open access: yesInternational Social Security Review, Volume 78, Issue 2-3, Page 173-190, April-September 2025.
Abstract This article critically examines perspectives on social protection’s role in strengthening resilience capacities in protracted crises – contexts where conflict and displacement persist for five years or longer. These crises shape how stakeholders navigate their mandates to provide support, while influencing how affected communities seek to ...
Carolina Holland‐Szyp, Jeremy Lind
wiley   +1 more source

500kV棒形悬式复合绝缘子芯棒脆断的预防措施

open access: yesDianci bileiqi, 2004
对500kV复合绝缘子芯棒脆断事故的发生原因进行了分析,指出芯棒断裂是由于绝缘子电压分布严重不均及均压环设计、安装不规范引起导线端电场畸变所致。通过对原线路双联悬垂复合绝缘子下垂式线夹挂点进行"八"字形改造;利用下垂式线夹缩短的距离在导线侧增挂玻璃绝缘子;新建线路采用特制复合绝缘子与玻璃绝缘子组合方式,使复合绝缘子均压环,接头连接处远离高压端,改善了复合绝缘子的电场分布,降低了复合绝缘子导线端承受的电压,消除了畸变电场,避免了棒形悬式复合绝缘子芯棒脆断,取得了良好的效果。
应伟国, 周松尧
doaj  

湿热环境电缆终端螺栓断裂机理及仿真分析

open access: yesGaoya dianqi, 2022
电缆终端在湿热沿海地区运行过程中会偶发法兰、螺栓断裂的机械故障,对电缆的安全运行产生严重的威胁。为了分析螺栓断裂机理和螺栓受力特性,文中分析了断裂螺栓的拉伸性能、化学成分变化、金相显微组织和表面形貌特征,然后通过有限元法对电缆终端中螺栓的应力应变特征进行了分析。研究表明断裂螺栓化学成分不符合标准,机械性能和抗腐蚀性能显著较差;在役电缆终端螺杆中部位置有较大的应力和形变量,是螺栓脆弱部位;因此,在沿海高湿热高盐雾环境作用和螺栓高应力作用发生应力腐蚀,螺杆中部表面位置腐蚀最快并最先出现裂纹,然后向里扩展 ...
范伟男, 王勇, 李光茂, 杜钢
doaj  