Results 1 to 10 of about 11,701 (148)

Analysis on Influence Factors of Temporary Overvoltage of Load Rejection Fault of Offshore Wind Power Transmission System of Permanent Magnet Synchronous Generator [PDF]

open access: yes, 2022
In order to evaluate the temporary overvoltage level of the wind power transmission system based on permanent magnet synchronous generator (PMSG) in case of load rejection, it is necessary to clarify the temporary overvoltage characteristics and its ...
CHEN Qiyu   +6 more
core   +1 more source

直流故障引发直流外送系统新能源脱网问题研究 [PDF]

open access: yes, 2023
含高比例新能源的直流外送系统由于送端发电设备支撑能力薄弱,在直流故障发生后新能源发电设备面临着过电压脱网风险。为了防止新能源脱网事故的发生,首先建立新能源直流外送系统仿真模型分析新能源机端暂态过电压形成机理,其次根据无功传输规律分析常规机组、调相机、电气距离等因素对新能源脱网的影响,定量分析常规机组的电压调节灵敏度,在此基础上利用新能源短路比指标对新能源脱网情况进行量化分析,最后根据分析结果提出了提高短路容量、提高风机高压穿越能力等预防直流故障后新能源脱网的策略 ...
严欢   +5 more
core   +1 more source

远海风电柔性直流送端交流系统故障协调控制 [PDF]

open access: yes, 2023
为提升远海风电对称双极柔性直流送端交流系统单相接地故障和两相短路故障工况(第一类故障)下的功率输送能力,以及三相接地故障工况(第二类故障)的交流电压稳定性,提出海上换流站协调控制策略。首先分析了第一类故障的过电压和极间环流产生机理,以及第二类故障的交流电压失稳机理。在此基础上,提出了功率平衡控制策略和输出有功电流策略。第一类故障下定电压控制极采用限压策略,功率平衡控制策略抑制极间环流,增大定电压控制极的功率,减少了交流电压控制器响应时间,提升了功率输送能力。第二类故障工况下 ...
叶荣   +4 more
core   +1 more source

海上风电柔性直流系统设计及工程应用 [PDF]

open access: yes, 2023
针对中国第一个海上风电柔性直流送出工程—江苏如东工程,从系统拓扑方案构建、过电压与绝缘配合、系统功率盈余问题与交流故障穿越技术以及控制保护技术等方面开展了深入研究,构建了轻型紧凑化的海上风电柔性直流系统拓扑方案,取消了海上换流站的启动回路与接地回路等;提出了海陆换流站的避雷器配置方案与参考电压的选取原则,形成了海陆换流站的绝缘配合方案的典型范式;提出了集中式、分布式、混合式直流侧有功功率动态平衡装置的典型拓扑方式,解决了陆上换流站交流侧故障穿越难题;提出了工程的整体控制保护方案 ...
卢亚军   +6 more
core   +1 more source

LCC-HVDC Converter Station Reactive Power Optimization and Two-Layer Coordination Strategy Research Based on Synchronous Sondenser [PDF]

open access: yes, 2023
[Introduction] Under the existing converter station reactive power compensation scheme, the synchronous condenser only provides transient reactive power support, and the AC (Alternating Current) filter undertakes steady-state reactive power compensation ...
Dongqing ZHANG   +3 more
core   +1 more source

考虑谐波谐振和电压稳定的海上风电场无功优化配置方法 [PDF]

open access: yes, 2023
海上风电经长距离高压交流海底电缆接入电网,海底电缆容升效应显著,容易引起工频过电压,同时电力电子器件和线路电容引起的谐波谐振问题也严重影响着电网电能质量,因此进行海上风电场无功配置时应充分考虑过电压和谐波谐振问题。针对上述问题,建立了海上风电场谐波模型,对海上风电场的谐波模态阻抗进行扫描,继而分析海上风电场的谐振特性;然后研究了海上风电场无功特性,计算各种发电出力水平和并网点电压下的风电场无功缺额;接着以降低综合成本为目标,以静态电压稳定裕度、最小补偿容量、谐波谐振及过电压为约束 ...
杜婉琳*, 梅桂华, 王玲, 马明
core   +1 more source

Research on Flexible HVDC Transmission Technology and Strategies for Improving the Operational Stability of IGBT Components [PDF]

open access: yes, 2023
[Introduction] With the continuous improvement of the strategic position of clean energy, more and more new energy power generation equipment is connected to the power grid, but its power quality is unstable, which has a great impact on the AC ...
Tao WANG   +3 more
core   +1 more source

特大型新能源基地面临挑战及未来形态演化分析 [PDF]

open access: yes, 2023
在推动中国新能源高质量跃升式发展背景下,大规模新能源开发、汇集和远距离输送成为新能源建设的重要路径之一,特大型新能源基地成为未来的重要形态。由于缺少常规交流同步发电机组和可靠备用容量,特大型新能源基地稳定性挑战、新能源利用率与供电充裕性矛盾凸显,其形态结构及演化路径成为当前关切的热点问题。系统梳理了当前最新学术研究成果,研判特大型新能源基地未来可能的源网形态并做特征分析;进一步,面向特大型新能源基地系统强度弱、灵活性不足、源网协调运行矛盾突出等挑战,针对性提出源网协调规划 ...
张玮   +5 more
core   +1 more source

Research on Lightning Performance and Protective Measures of ±800 kV UHVDC Power Transmission Line [PDF]

open access: yes, 2023
[Introduction] Lightning strike is the primary cause of failures of ±800 kV UHVDC power transmission lines, and the lightning protection assessment of power transmission lines is critical to the safe and stable operation of the system.
Youjun GONG, Zhiwen HE, Ziwei YAN
core   +1 more source

高压断路器切除并联电抗器过电压的抑制研究

open access: yesGaoya dianqi, 2021
高压断路器切除并联电抗器时会产生较高的过电压,而导致设备故障,危及电网安全运行。文中从开断电抗器产生过电压的原理出发,并结合试验结果分析过电压的区间分类,提出了重燃窗口以及过电压临界点的划分方法,详细分析了选相分闸技术抑制过电压的原理,并通过试验验证其可有效控制过电压在较低水平,从而消除过高的过电压对电力设备的威胁。
陈杳伟, 史俊, 党德旺, 付杰
doaj  