Results 11 to 20 of about 1,483,627 (232)

Evaluation of Three-Dimensional Conformal Radiotherapy and Intensity Modulated Radiotherapy Techniques for Left Breast Post-Mastectomy Patients: Our Experience in Nigerian Sovereign Investment Authority-Lagos University Teaching Hospital Cancer Center, South-West Nigeria

open access: yesEuropean Journal of Breast Health, 2021
Objective:This study aimed to evaluate the dosimetric properties of treatment plans obtained from three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy techniques (IMRT) plans for left chest wall breast cancer patients ...
Samuel Adeneye   +9 more
doaj   +1 more source

Dosimetric Comparison of IMRT with 3D-CRT Regarding Their Contribution to the Treatment Plan Optimization Using Rando Phantom with a Realistic Lung Cancer Radiotherapy Treatment Planning [PDF]

open access: yesIranian Journal of Medical Physics, 2021
Introduction: This study compared a three-dimensional conformal radiation therapy (3D-CRT) with a recently implemented intensity modulation radiation therapy (IMRT) technique performed in the irradiation of lung cancer.
Karim Benkahila   +3 more
doaj   +1 more source

Dosimetric Analysis with Intensity-modulated Radiation Therapy for Central Nervous System Irradiation in Patients with Brain Cancer Compared with Three-dimensional Conformal Radiation Therapy Treatment

open access: yesPolytechnic Journal, 2019
Intensity-modulated radiation therapy (IMRT) was put as the development of three-dimensional conformal radiation therapy (3D-CRT). The purpose of the present study is to compare the dosimetric analysis of two techniques of radiotherapy (IMRT) and 3D-CRT,
Noor S. Omar, Ronak T. Ali
doaj   +1 more source

Craniospinal Irradiation of Pediatric Medulloblastoma, Dosimetric Comparison between Helical Tomotherapy, and Conventional Radiation Therapy [PDF]

open access: yesMiddle East Journal of Cancer, 2022
Background: Dosimetric comparison between 3D-conformal radiation therapy (3D-CRT) and helical tomotherapy (HT) in pediatric Medulloblastoma (MB) receiving craniospinal irradiation (CSI).Method: This was a retrospective dosimetric study on five pediatric ...
Mohamed Hegazy, Maamoun Shehadeh
doaj   +1 more source

Efficacy and safety of intensity-modulated radiation therapy versus three-dimensional conformal radiation treatment for patients with gastric cancer: a systematic review and meta-analysis

open access: yesRadiation Oncology, 2019
Background Radiation or radiochemotherapy is a common adjuvant therapy for gastric cancer. Intensity-modulated radiation therapy (IMRT) has been demonstrated to provide better dose conformity, allowing dose escalation and/or reduction of normal tissue ...
Fang Ren   +6 more
doaj   +1 more source

A prospective Phase III trial evaluating patient self‐reported pain and cosmesis in accelerated partial breast irradiation utilizing 3‐D versus intensity‐modulated radiotherapy

open access: yesCancer Medicine, 2021
Purpose/Objective The primary objective is to examine patient self‐assessment of breast pain and cosmesis between three‐dimensional (3D‐CRT) versus intensity‐modulated radiotherapy (IMRT).
Charles E. Leonard   +13 more
doaj   +1 more source

Comparison Between Dose-Escalated Intensity Modulated Radiation Therapy and 3-Dimensional Conformal Radiation Therapy for Salvage Radiation Therapy After Prostatectomy

open access: yesAdvances in Radiation Oncology, 2021
Purpose: To compare long-term outcomes and late toxicity between patients treated with 3-dimensional conformal radiation therapy (3D-CRT) and with dose-escalated intensity modulated radiation therapy (IMRT) as salvage radiation therapy (SRT) after ...
Nana Shimoyachi, MD   +8 more
doaj   +1 more source

Treating lung cancer with dynamic conformal arc therapy: a dosimetric study

open access: yesRadiation Oncology, 2017
Background Lung cancer patients are often in poor physical condition, and a shorter treatment time would reduce their discomfort. Dynamic conformal arc therapy (DCAT) offers a shorter treatment time than conventional 3D conformal radiotherapy (3D CRT ...
Primož Peterlin   +3 more
doaj   +1 more source

Integral Dose and Dosimetric Comparison of 3D-CRT, IMRT and VMAT Radiotherapy Techniques for Prostate Cancer [PDF]

open access: yesIranian Journal of Medical Physics
Introduction: This study aimed to compare the treatment planning volumes and the integral doses (ID) during radiotherapy for prostate cancer using three-dimensional conformal radiotherapy (3D-CRT), intensity-modulated radiotherapy (IMRT), and volumetric ...
Özlem Mermut   +4 more
doaj   +1 more source

Comparison of 3D confromal radiotherapy and intensity modulated radiotherapy with or without simultaneous integrated boost during concurrent chemoradiation for locally advanced head and neck cancers.

open access: yesPLoS ONE, 2014
ObjectiveRadiotherapy techniques have evolved from 3D conformal radiotherapy (3D-CRT) to intensity modulated radiotherapy (IMRT) where boost fields are delivered either sequentially (IMRTseq) or with a simultaneous integrated boost (IMRT+SIB).
Michael T Spiotto, Ralph R Weichselbaum
doaj   +1 more source

Home - About - Disclaimer - Privacy