Results 21 to 30 of about 17,535 (160)
Purpose: To compare long-term outcomes and late toxicity between patients treated with 3-dimensional conformal radiation therapy (3D-CRT) and with dose-escalated intensity modulated radiation therapy (IMRT) as salvage radiation therapy (SRT) after ...
Nana Shimoyachi, MD +8 more
doaj +1 more source
Background Radiation or radiochemotherapy is a common adjuvant therapy for gastric cancer. Intensity-modulated radiation therapy (IMRT) has been demonstrated to provide better dose conformity, allowing dose escalation and/or reduction of normal tissue ...
Fang Ren +6 more
doaj +1 more source
Purpose/Objective The primary objective is to examine patient self‐assessment of breast pain and cosmesis between three‐dimensional (3D‐CRT) versus intensity‐modulated radiotherapy (IMRT).
Charles E. Leonard +13 more
doaj +1 more source
Treating lung cancer with dynamic conformal arc therapy: a dosimetric study
Background Lung cancer patients are often in poor physical condition, and a shorter treatment time would reduce their discomfort. Dynamic conformal arc therapy (DCAT) offers a shorter treatment time than conventional 3D conformal radiotherapy (3D CRT ...
Primož Peterlin +3 more
doaj +1 more source
ObjectiveRadiotherapy techniques have evolved from 3D conformal radiotherapy (3D-CRT) to intensity modulated radiotherapy (IMRT) where boost fields are delivered either sequentially (IMRTseq) or with a simultaneous integrated boost (IMRT+SIB).
Michael T Spiotto, Ralph R Weichselbaum
doaj +1 more source
Integral Dose and Dosimetric Comparison of 3D-CRT, IMRT and VMAT Radiotherapy Techniques for Prostate Cancer [PDF]
Introduction: This study aimed to compare the treatment planning volumes and the integral doses (ID) during radiotherapy for prostate cancer using three-dimensional conformal radiotherapy (3D-CRT), intensity-modulated radiotherapy (IMRT), and volumetric ...
Özlem Mermut +4 more
doaj +1 more source
Comparison of Volumetric Modulated Arc Therapy and Three-Dimensional Conformal Radiotherapy in Postoperative High-Grade Glioma: A Dosimetric Comparison [PDF]
Introduction: We aimed to dosimetrically compare three-dimensional conformal radiotherapy (3D-CRT) and volumetric modulated arc therapy (VMAT) in terms of planning target volume (PTV) coverage, organ at risk (OAR) sparing, and conformity index (CI ...
Harikesh Singh +12 more
doaj +1 more source
IMRT or 3D-CRT in Glioblastoma? A Dosimetric Criterion for Patient Selection
Intensity modulated radiation therapy (IMRT) is increasingly employed in glioblastoma (GBM) treatment. The present work aimed to assess which clinical-dosimetric scenario could benefit the most from IMRT application, with respect to three-dimensional conformal radiation therapy (3D-CRT).
Lorentini S +7 more
openaire +3 more sources
Background To quantitatively evaluate the safety and related-toxicities of intensity modulated radiotherapy (IMRT) dose–volume histograms (DVHs), as compared to the conventional three-dimensional conformal radiotherapy (3D-CRT), in gynecologic malignancy
Yang Baojuan +5 more
doaj +1 more source
Simultaneous Bilateral Chest Wall Irradiation, Can Helical Tomotherapy Improve Dose Distribution? [PDF]
Background: Radiotherapy to bilateral breast cancer (BBC) is technically challenging because of the proximity to organs as the heart and lungs. Aim: We conducted this study tocompare helical tomotherapy (HT) to 3-dimensional conformal radiation therapy ...
Ahmed Elashwah, Amr Mousa, Ghadeer Nazer
doaj +1 more source

