Results 141 to 150 of about 1,486,900 (338)
Long‐term stability analysis of beam shape in a robotic radiosurgery system
Abstract Purpose This study aimed to investigate the long‐term stability of CyberKnife beam profile parameters and assess their compliance with existing quality assurance (QA) guidelines. We evaluated beam profiles in both standard and diagonal planes over 3.5 years post‐installation to detect potential issues and ensure consistent beam quality.
Ryoichi Hinoto+4 more
wiley +1 more source
FUNCTIONAL PARALYSIS OF THE DIAPHRAGM IN TWO CASES WITH ACCELERATION OF RESPIRATION [PDF]
Adrianna Watson, J. S. Meighan
openalex +1 more source
Abstract Purpose This study aims to develop a CycleGAN based denoising model to enhance the quality of low‐dose PET (LDPET) images, making them as close as possible to standard‐dose PET (SDPET) images. Methods Using a Philips Vereos PET/CT system, whole‐body PET images of fluorine‐18 fluorodeoxyglucose (18F‐FDG) were acquired from 37 patients to ...
Yang Liu, ZhiWu Sun, HaoJia Liu
wiley +1 more source
Abstract Purpose The aim of this work was to report on the optimization, commissioning, and validation of a beam model using a commercial independent dose verification software RadCalc version 7.2 (Lifeline Software Inc, Tyler, TX, USA), along with 4 years of experience employing RadCalc for offline and online monitor unit (MU) verification on the ...
Urszula Jelen+3 more
wiley +1 more source
Primary and secondary alkyl iodides and primary alkyl bromides were quickly and conveniently converted into their corresponding alkyl chlorides via SN2 halide-halide substitution.
Brian T. Zielke II
doaj
Radiotherapy medical physics in the Philippines: A contemporary overview
Abstract Purpose With cancer ranking as the third leading cause of death in the Philippines and a disparity in healthcare resources across regions, this research aimed to assess the state of radiotherapy medical physics in the country. Methodology The study utilized a comprehensive online survey with 94 structured questions answered by 19 clinics ...
John Paul C. Cabahug+4 more
wiley +1 more source
Localization accuracy of 6‐second CBCT for lung IGRT with various breathing patterns
Abstract Purpose The 6‐second cone beam computed tomography (CBCT) acquisition of the Ethos HyperSight (Varian Medical Systems, Inc. Palo Alto, CA, USA) on‐board imaging system offers benefits, but could be too fast to accurately capture an average target position in a free‐breathing lung cancer patient. This study aimed to ascertain whether a 6‐second
Jihye Koo+5 more
wiley +1 more source