Results 191 to 200 of about 29,605,726 (275)
La0.5Sr3.5Fe3O7.5F2.6, a rare n = 3 Ruddlesden–Popper oxyfluoride, exhibits robust antiferromagnetism across a wide temperature range from 1.7 to 470 K. Temperature‐dependent neutron diffraction reveals an orthorhombic nuclear and a monoclinic magnetic structure, while Mößbauer spectroscopy shows persistent short‐range magnetic order up to 525 K.
Andy Bivour +9 more
wiley +1 more source
Proof-of-principle demonstration of epithermal neutron resonance spectroscopy utilizing a compact laser-driven electron accelerator. [PDF]
Feng J +12 more
europepmc +1 more source
Replacing conventional position‐sensitive photomultiplier tube detector systems with a square array of four flat‐panel‐type photomultiplier tube detectors enables simultaneous very small angle and small‐angle neutron scattering measurements, while improving the effective neutron detection area, spatial resolution, sensitivity and signal‐to‐background ...
Miki Sasaki +3 more
wiley +1 more source
Development and dosimetric evaluation of a freely deformable <sup>6</sup>Li-based neutron shield for boron neutron capture therapy. [PDF]
Hu N +13 more
europepmc +1 more source
ABSTRACT The specific depth‐profiling capabilities of the muonic x‐ray emission spectroscopy (μ‐XES) technique have proved to be effective for examination of the elemental distribution within ancient coins. This ‘layered’ analysis can also be applied to the examination of ancient faience, the production of which can result in distinct layers (glaze ...
Juliet V. Spedding +2 more
wiley +1 more source
Vacancy-mediated ultrafast oxide-ion conduction in excess-oxygen Sillén oxybromides. [PDF]
Kanenori Y +10 more
europepmc +1 more source
One‐more‐vertex Next‐Event Estimation with Hierarchical Geometry Sampling
Abstract Robust next‐event estimation (NEE) remains a challenge in scenes characterized by sparse or small‐scale geometry where indirect illumination is the primary transport mechanism. In these scenes, traditional path construction, which relies on local directional sampling, often fails to find intersections with the sparse geometry, and standard NEE
Jorge Garcia‐Pueyo +3 more
wiley +1 more source
Pilot full-scale demonstration of a prototype table-top neutron resonance transmission analysis system for nuclear material detection. [PDF]
Guembou Shouop CJ, Tsuchiya H.
europepmc +1 more source
Appraisal of Six Natural Mica Reference Materials for In Situ Rb‐Sr Geochronology
Key Points Evaluated six natural mica reference materials for in situ LA‐ICP‐MS/MS Rb‐Sr geochronology using geochemical, microstructural and isotopic characterisation. Identified robust primary reference materials: Mount Dromedary biotite (99.37 Ma) and Mica‐Fe biotite (307.75 Ma). La Posta biotite and Högsbo muscovite are suitable secondary reference
Hugo K.H. Olierook +38 more
wiley +1 more source

